Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>YOKOGAWA>Yokogawa AAV144-S50 16-Channel Isolated Voltage Input Module
Yokogawa AAV144-S50 16-Channel Isolated Voltage Input Module

Yokogawa AAV144-S50 16-Channel Isolated Voltage Input Module Item NO.: 2932308

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Yokogawa AAV144-S50 16-Channel Isolated Voltage Input Module
Item NO. 2932308
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category YOKOGAWA
Brand YOKOGAWA
Creation Time 2026-11-13

YokogawaISOLATED VOLTAGE AI

Yokogawa AAV144-S5016-Channel Isolated Voltage Input Module

01

Product Information

Yokogawa AAV144-S50 is a 16-channel isolated voltage input module for CENTUM VP field I/O. It accepts either 1 to 5 V DC or -10 to 10 V DC input service, with the selected signal range applied together across channels 1 through 16.

The S50 suffix of AAV144-S50 identifies the standard type, non-explosion-protected construction and basic environmental specification. Each channel is isolated, the data update period is 10 ms, and the module permits up to ±30 V at the input within the documented electrical conditions.

AAV144-S50 converts the selected voltage range into process data for the field control station while preserving channel-to-channel and channel-to-system separation. Because one range selection applies across all 16 channels, the connected signal sources must belong to the same voltage-range group.

Yokogawa AAV144-S50 isolated voltage input specifications from the official manual
02

Product Specifications

Specification AAV144-S50
Brand Yokogawa
Product Name 16-Channel Isolated Voltage Input Module
Country Not specified
Input channels 16 isolated channels
Selectable input ranges 1 to 5 V DC or -10 to 10 V DC
Range assignment Selected together for channels 1 to 16
Allowable input voltage ±30 V
Input resistance, power on 1 MΩ
Input resistance, power off 200 kΩ
Accuracy at 1 to 5 V ±4 mV
Accuracy at -10 to 10 V ±20 mV
Data update period 10 ms
Withstanding voltage 1500 V AC for 1 minute
Maximum current consumption 500 mA at 5 V DC
Approximate weight 0.2 kg
03

Operating Characteristics

AAV144-S50 measures isolated voltage channels with one module-wide range choice, making range consistency as important as individual loop continuity.

01

Sixteen isolated inputs

Each voltage channel is isolated from the system and neighboring channels, limiting the spread of field reference differences.

02

Two supported ranges

The module supports 1 to 5 V or -10 to 10 V service; the selected range applies collectively rather than as a different choice on every channel.

03

Defined update and accuracy

A 10 ms update period and range-specific accuracy figures define the module contribution to the measurement path.

04

Configuration and Programming

Engineering AAV144-S50 begins with the correct module-wide voltage range and then applies channel scaling, alarm limits and tag identity.

01

Select the common range

Confirm all connected channels belong to the selected 1 to 5 V or -10 to 10 V range before activating the module.

02

Scale engineering units

Convert each channel voltage to its process unit using the transmitter or signal-source record, not by copying a neighboring tag scale.

03

Set credible alarms

Apply underrange, overrange and bad-input handling that distinguishes a real process excursion from an open, shorted or incorrectly ranged signal.

05

Questions & Answers

Q01Can AAV144-S50 mix 1 to 5 V and -10 to 10 V devices on the same module?

AAV144-S50 selects the input range together for channels 1 through 16, so mixed ranges require a different module allocation or external signal arrangement.

Q02Why must ±30 V not be treated as the normal AAV144-S50 measurement range?

The ±30 V value for AAV144-S50 is the allowable input limit, not the configured measurement range. Normal engineering must use 1 to 5 V or -10 to 10 V as documented.

Q03Why does AAV144-S50 show incorrect values on every channel after a project change?

For AAV144-S50, check the module-wide range selection first. Changing between 1 to 5 V and -10 to 10 V affects all 16 channels and can make otherwise correct wiring appear wrong.

Q04What does a stable zero-like value mean on one AAV144-S50 channel?

On AAV144-S50, verify terminal voltage with a meter, channel scaling, cable continuity and the field-source reference. Isolation means a single dead channel often points to its own loop rather than the shared module.

Q05What should be included in an AAV144-S50 replacement handover?

Record AAV144-S50, slot, selected range, channel scaling, terminal interface and pre-change voltage readings so the new module can be checked against the original configuration.

Q06How should AAV144-S50 be distinguished from similarly shaped current-input modules?

Use the full AAV144-S50 label and project record. The enclosure family is shared, while the AAV144 electrical function is isolated voltage input.

06

Obsolete Parts Support

Moore Automation

https://www.mvme.cn/

Moore Automation accepts enquiries for legacy industrial components using the complete manufacturer and model string, label images and any available equipment records.

Requested legacy parts and proposed alternatives are kept as separate commercial lines until the customer confirms the acceptable scope, preventing a similar family code from being presented as an automatic replacement.

Legacy model reviewLabel detail captureAlternative separationRecord continuity
Moore Automation company service image for AAV144-S50
07

Suggested Products

Siemens6ES7412-1XJ05-0AB0
ABB3HNA029043-0
SiemensSKC32.60
ABB3HNA023093-001
Siemens6GK7343-1EX20-0XE0
ABB3HNA018784-001
Siemens6ES7124-1FA00-0AB0
ABB3HNA024284-001
Siemens6GK7442-1RX00-0XE0
ABBBRC300 / SPBRC300
ABBBRC400 / SPBRC400
ABBBRC410 / SPBRC410
ABBBRC100 / SPBRC100
Siemens6ES7323-1BL00-0AA0
ABBDI810 3BSE008508R1
GEIC695ACC400-DA
Schneider Electric140XTS00100
Rockwell Automation1756-EN2TR
OmronCP1W-40EDT
Bently Nevada21000-16-10-00-054-04-02
HoneywellLCM-320
Mitsubishi ElectricFX1N-40MR-ES/UL
Allen-Bradley700-K40E-ZY
B&RX20CP1684X
YaskawaCIMR-AC4A0072AAA
WAGO750-613/006-000
BeckhoffKL3062
FoxboroFBM201C
Bosch RexrothVT-VRPA2-1-11/V0/T1
HIMAX-COM 01 001
LenzeE82EV152-4B
EmersonVE801R
Vibro-Meter444-620-000-111-A1-B100-C01
YokogawaAAI143-S50/A4S00
ProSoft2150-AGA 1747-KE
TRICONEX8310
MotorolaMVME167-033B
SICKCLV250-1020
Phoenix ContactRAD-0200
SEW-EURODRIVEMDX61B0008-5A3-4-0T
Triconex3626X
DanfossVLT2840
ICS TriplexT8151C
Woodward9907-010
MoxaEDS-405A-MM-ST-T
Pepperl+FuchsRLK39-8-2000/31/40a/116
FestoCPX-M-FB33
FANUCA05B-1523-B202
GE FanucIC670GBI001
ifmPN5000
KnickB12526800A
Rockwell Drives80026-044-06-R
EatonDILM65 XTCE065D00F
HornerHE800RTD000
ADLEEAS2-115
ANYBUS021620-B
BalluffBCL45R1F100
Eaton MTL787S
FMSEMGZ306A
HORNERHE800WCM900
08

Contact Information

CompanyMoore Automation
Manager / EmailLeoniasales@mvme.cn
Expanded product page image

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.