Analog measurement
Channels assigned as analog inputs acquire 4 to 20 mA process values and can expose supported HART variables alongside the primary signal.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Yokogawa A2MMM843-SS1130 16-Channel Analog / Digital I/O Module with HART |
| Item NO. | 2932305 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | YOKOGAWA |
| Brand | YOKOGAWA |
| Creation Time | 2026-11-13 |
Yokogawa A2MMM843-SS1130 is a 16-channel isolated N-IO module whose channels can be assigned as analog input, analog output, digital input or digital output. The analog paths support HART communication, allowing one module type to host a carefully engineered mixture of field signal functions.
The SS1130 suffix of A2MMM843-SS1130 identifies the standard analog I/O function, standard digital I/O function, fixed design code, explosion-protected construction, and G3 environmental treatment with the -40 to 70 °C operating range. Those codes describe one complete hardware variant rather than optional software labels.
Within A2MMM843-SS1130, each channel is isolated and its function is selected through engineering. HART variables can be used with analog channels, while on-demand communication can be routed through the supported plant resource management environment.
| Specification | A2MMM843-SS1130 |
|---|---|
| Brand | Yokogawa |
| Product Name | 16-Channel Analog / Digital I/O Module with HART |
| Country | Not specified |
| Platform | N-IO |
| Channel count | 16 isolated channels |
| Selectable functions | Analog input, analog output, digital input or digital output |
| Analog signal | 4 to 20 mA DC |
| HART communication | Available for supported analog channels |
| Digital input | Dry-contact input arrangement |
| Digital output | 24 V DC transistor output arrangement |
| Isolation | Channel-to-system and channel-to-channel |
| Explosion protection | Included by suffix code |
| Environmental treatment | G3 |
| Operating temperature code | -40 to 70 °C |
| Engineering requirement | Per-channel function assignment |
A2MMM843-SS1130 brings measurement, command and discrete state functions into one isolated channel set; the engineering database determines what each physical channel means.
Channels assigned as analog inputs acquire 4 to 20 mA process values and can expose supported HART variables alongside the primary signal.
Channels assigned as analog outputs send 4 to 20 mA commands to compatible field devices, with external loop conditions retained in the cabinet design.
Remaining channels can be assigned as contact inputs or transistor outputs, letting one N-IO module handle a mixed field bundle without changing hardware type.
The A2MMM843-SS1130 signal path connects channel-level HART data, on-demand device communication and the N-IO node communication structure.
The field control station reads HART variables from the module I/O image while ordinary control blocks continue to use the primary process values.
Supported PRM access can address field devices without making the control application responsible for every maintenance transaction.
The module connects through its N-IO unit and node interface; it does not provide a standalone plant-network connector on the front module body.
With A2MMM843-SS1130, review the number of HART devices, polling method, PRM on-demand traffic, field wiring quality and refresh expectations before treating the module as faulty.
For A2MMM843-SS1130, confirm the exact channel capability, selected analog/digital direction, node firmware and project software revision. A mixed-I/O module still enforces valid function combinations.
For A2MMM843-SS1130, compare the channel direction, output range, downloaded point assignment, application command and field loop supply before treating the output circuit as failed.
A2MMM843-SS1130 uses isolated channels, so a polarity, supply or field-device fault can remain local to one point. Check that loop before investigating the entire N-IO node.
With A2MMM843-SS1130, compare the primary process update with HART or PRM response. Normal control values with slow device variables point to the HART communication path rather than the channel conversion path.
Export the A2MMM843-SS1130 channel assignment, tags, ranges, HART devices and safe states before removal. Reinstalling identical hardware does not recreate a missing engineering database.
Moore Automation services cover model-record review, document coordination, quotation preparation, packing communication and shipment follow-up for industrial automation components.
Each request can retain its manufacturer, complete model, quantity and accessory scope from the first enquiry through the commercial and delivery records.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found