Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>VIBRO METER>Meggitt Vibro-Meter RPS6U 200-582-200-122 / RPS6U 200-582-200-011 | RPS6U 24 VDC rack power supplies
Meggitt Vibro-Meter RPS6U 200-582-200-122 / RPS6U 200-582-200-011 | RPS6U 24 VDC rack power supplies

Meggitt Vibro-Meter RPS6U 200-582-200-122 / RPS6U 200-582-200-011 | RPS6U 24 VDC rack power supplies Item NO.: 2921987

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Meggitt Vibro-Meter RPS6U 200-582-200-122 / RPS6U 200-582-200-011 | RPS6U 24 VDC rack power supplies
Item NO. 2921987
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category VIBRO METER
Brand OTHER PRODUCTS
Creation Time 2026-10-16

Meggitt Vibro-Meter RPS6U 200-582-200-122 / RPS6U 200-582-200-011 | RPS6U 24 VDC rack power supplies
Meggitt Vibro-Meter · VM600Mk2 / VM600 machinery monitoring systems

Meggitt Vibro-Meter RPS6U 200-582-200-122 / RPS6U 200-582-200-011 | RPS6U 24 VDC rack power supplies

Convert a 24 VDC input into the +5 VDC and ±12 VDC rails used by an ABE04x rack

01

Product Overview

Meggitt Vibro-Meter RPS6U 200-582-200-122 / RPS6U 200-582-200-011 identifies two 24 VDC-input RPS6U rack power-supply versions for VM600Mk2 / VM600 ABE04x racks. Each unit occupies a front power-supply position and feeds the rack backplane rather than a separate field load.

From the incoming 24 VDC source, RPS6U 200-582-200-122 / RPS6U 200-582-200-011 generates +5 VDC and ±12 VDC rails. Those rails pass through the two high-current backplane connectors to the rack and its installed processing and I/O cards.

Protection and status circuits in RPS6U 200-582-200-122 / RPS6U 200-582-200-011 act on supply conditions before power reaches the rack. A second RPS6U can provide redundant rack power when the ABE04x installation and rear input panel are wired for two independent feeds.

VM600Mk2 RPS6U front, side and top mechanical drawing
VM600Mk2 RPS6U front, side and top mechanical drawing
Full-size VM600Mk2 RPS6U front, side and top mechanical drawing×
02

Technical Specifications

Brand
Meggitt Vibro-Meter
Product type
RPS6U rack power supplies
Product family
VM600Mk2 / VM600
Complete models
RPS6U 200-582-200-122 / RPS6U 200-582-200-011
Input family
24 VDC
Rack position
Front RPS6U slot in ABE04x rack
Backplane connection
Two high-current connectors
Output rails
+5 VDC and ±12 VDC
Newer-version maximum output
330 W
Earlier-version maximum output
300 W
+5 V rail
Up to 50 A
+12 V rail
Up to 8 A
-12 V rail
Up to 4 A
Line regulation
Less than ±1%
Output protection
Over-voltage, short-circuit and overload
Status indication
Power-supply status indicators
Redundant arrangement
Two RPS6U supplies in supported rack configuration
Temperature note
Derating or forced cooling applies at elevated rack temperature
03

Operating Characteristics

RPS6U 200-582-200-122 / RPS6U 200-582-200-011 convert the external 24 VDC feed into the three rails used by the ABE04x backplane, with output capacity governed by hardware version, rack load and temperature.

  1. 01

    Three-rail conversion

    Each RPS6U 200-582-200-122 / RPS6U 200-582-200-011 converts 24 VDC into +5 VDC, +12 VDC and -12 VDC. The +5 V rail carries the largest card load, while the ±12 V rails serve the rack circuits that require bipolar supplies.

  2. 02

    Backplane delivery

    Two DIN 41612 H15 high-current connectors couple RPS6U 200-582-200-122 / RPS6U 200-582-200-011 to the ABE04x backplane. Power and status signals therefore enter the rack through the rear connectors rather than through field terminals on the front panel.

  3. 03

    Load and temperature relationship

    A later RPS6U version can supply up to 330 W, while the earlier rated-power version is limited to 300 W. Above 50 °C, card population and cooling method determine the permitted combined load on RPS6U 200-582-200-122 / RPS6U 200-582-200-011.

04

Diagnostics and Protection

The front indicators, rear power-check path and internal protection stages separate an external-feed problem from a failed conversion rail or an overloaded rack.

  1. 01

    Input and rail indicators

    The green IN indicator on RPS6U 200-582-200-122 / RPS6U 200-582-200-011 confirms that the external feed is present and within range. Separate yellow +5 V, +12 V and -12 V indicators show which regulated outputs are being generated.

  2. 02

    Protection response

    Output overvoltage protection latches off the affected RPS6U 200-582-200-122 / RPS6U 200-582-200-011 supply. Short-circuit and overload protection recover automatically after the excessive load is removed.

  3. 03

    Redundant supply path

    Two RPS6U units can operate redundantly when the rack uses independent input paths. If one supply stops, the other must be sized to carry the complete rack load rather than only its previous share.

05

Frequently Asked Questions

What does RPS6U 200-582-200-122 / RPS6U 200-582-200-011 power inside an ABE04x rack?

RPS6U 200-582-200-122 / RPS6U 200-582-200-011 feeds the ABE04x backplane and all installed rack cards through +5 VDC and ±12 VDC rails.

Why must the exact RPS6U 200-582-200-122 / RPS6U 200-582-200-011 version be kept in the record?

The complete RPS6U 200-582-200-122 / RPS6U 200-582-200-011 record separates the newer 330 W 122 version from the earlier 300 W 011 version. That difference affects rack-power planning even though both use a 24 VDC input family.

How are the output rails from RPS6U 200-582-200-122 / RPS6U 200-582-200-011 distributed?

Two high-current connectors carry the converted rails from RPS6U 200-582-200-122 / RPS6U 200-582-200-011 directly into the rack backplane.

Which condition should be checked before removing RPS6U 200-582-200-122 / RPS6U 200-582-200-011?

Confirm the rear-panel 24 VDC input and isolate it before removing RPS6U 200-582-200-122 / RPS6U 200-582-200-011; a dark front indicator can originate upstream.

How does a redundant rack use RPS6U 200-582-200-122 / RPS6U 200-582-200-011?

A redundant rack using RPS6U 200-582-200-122 / RPS6U 200-582-200-011 installs two supply units and two independent input paths, so one path can be checked without treating both feeds as a single source.

What can cause a loaded RPS6U 200-582-200-122 / RPS6U 200-582-200-011 rack to require forced cooling?

High rack temperature and card loading increase thermal demand. At elevated temperature, RPS6U 200-582-200-122 / RPS6U 200-582-200-011 can require output derating or forced cooling.

06

Why Choose Moore Automation

Moore Automation

Moore Automation works with industrial control, machinery monitoring and automation spares from multiple manufacturers. Each product line is recorded with its complete identifier, manufacturer and product type.

Nameplate photographs, existing drawings and installed-system details can be kept with the complete requested identifier. This gives technical, commercial and logistics records one consistent product reference.

Exact referencesComplete part numbers remain visible
Industrial scopeAutomation and machinery-monitoring hardware
Document continuityModels, drawings and shipment records stay linked
Moore Automation why choose moore automation imagewww.mvme.cn
Full-size Moore Automation image×
08

Contact Information

Contact Information

Discuss the exact product reference and installed-system requirement with Moore Automation.

ManagerLeonia
Emailsales@mvme.cnWhatsApp+86 180 3017 5807
Moore Automation · RPS6U 24 VDC rack power suppliesModel reference: RPS6U 200-582-200-122 / RPS6U 200-582-200-011

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.