Rack input
The configured AC supply enters the RPS6U module through the rack power connection.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Vibro-Meter RPS6U 200-582-500-122 | VM600Mk2 rack power supply |
| Item NO. | 2918974 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | VIBRO METER |
| Brand | OTHER PRODUCTS |
| Creation Time | 2026-10-13 |
Vibro-Meter industrial hardware
VM600Mk2 rack power supply · Meggitt Vibro-Meter VM600Mk2 · exact-model selection
Installed in a Meggitt Vibro-Meter VM600Mk2 rack, RPS6U 200-582-500-122 is a rack power-supply module. It sits in the rack power path and provides the internal supply rails required by the rack modules, so the input option and complete model code define the correct rack power identity.
Power enters RPS6U 200-582-500-122 through its AC rack connection and is converted into the rails used by the VM600Mk2 electronics. Those rails leave through the rack backplane, where the installed monitoring modules receive their operating supply rather than a sensor signal.
The physical position of RPS6U 200-582-500-122 is consequently part of the rack power path: its designated supply slot, input wiring, connector position, and VM600Mk2 backplane connection work together. The module does not carry a process measurement channel.
| Technical Item | RPS6U 200-582-500-122 |
|---|---|
| Brand | Vibro-Meter |
| Product Type | Rack power supply |
| System | VM600Mk2 |
| Input Class | AC input configuration |
| Rack Function | Power conversion and distribution |
| Output Path | VM600Mk2 rack backplane |
| Module Position | VM600Mk2 rack power-supply slot |
| Selection Check | Rack type, input, connector, and code |
| Replacement Identity | Keep RPS6U and 200-582-500-122 together |
RPS6U 200-582-500-122 handles rack power rather than a process measurement; the conversion path ends at the VM600Mk2 backplane rails.
The configured AC supply enters the RPS6U module through the rack power connection.
The power module converts the input into the rails used by the rack electronics.
The converted rails are distributed to the installed VM600Mk2 modules.
RPS6U 200-582-500-122 must match the VM600Mk2 rack position and input wiring before the rack is energized.
Use the designated power-supply slot, not a measurement-module slot.
Match the rack input arrangement to the ordered RPS6U configuration.
The RPS6U does not provide a sensor or monitoring channel.
For Vibro-Meter RPS6U 200-582-500-122, The configured AC input enters the RPS6U module, is converted into internal rails, and leaves through the VM600Mk2 backplane to the rack electronics.
For Vibro-Meter RPS6U 200-582-500-122, RPS6U supplies the rack; it does not receive a sensor signal or produce a vibration value. Measurement modules use the rails distributed by the backplane.
RPS6U 200-582-500-122 belongs in the VM600Mk2 rack power-supply slot, not in a sensor or monitoring-module position.
For Vibro-Meter RPS6U 200-582-500-122, The rack type, input wiring, connector position, and complete RPS6U code describe the same power path. Mechanical fit alone does not establish that relationship.
For Vibro-Meter RPS6U 200-582-500-122, The backplane receives the converted rails from RPS6U and distributes them to the installed VM600Mk2 modules. It is the output path of the power supply, not a field-signal input.
For Vibro-Meter RPS6U 200-582-500-122, No. A probe connects to its designated monitoring chain; RPS6U only provides the rack power used by those modules.
https://www.mvme.cn/
Moore Automation is presented as an industrial automation spare-part supply channel with a named contact and a direct web address.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found