Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>VIBRO METER>Meggitt Vibro-Meter EA402 913-402-000-012 | EA402 extension cable
Meggitt Vibro-Meter EA402 913-402-000-012 | EA402 extension cable

Meggitt Vibro-Meter EA402 913-402-000-012 | EA402 extension cable Item NO.: 2921731

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Meggitt Vibro-Meter EA402 913-402-000-012 | EA402 extension cable
Item NO. 2921731
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category VIBRO METER
Brand OTHER PRODUCTS
Creation Time 2026-10-15

Meggitt Vibro-Meter EA402 913-402-000-012 | EA402 extension cable
Meggitt Vibro-Meter · TQ4xx proximity measurement hardware

Meggitt Vibro-Meter EA402 913-402-000-012 | EA402 extension cable

A defined coaxial extension path for TQ402/TQ412 probes and the IQS900 signal conditioner.

EA402 extension cableEA402913-402-000-012PROBE · EXTENSION · CONDITIONER
01

Product description

Meggitt Vibro-Meter EA402 913-402-000-012 is an EA402 extension cable for the TQ4xx proximity measurement system. It extends the probe's integral coaxial cable so the sensing chain can reach the IQS900 signal conditioner without changing the probe's measurement function.

In a TQ402 or TQ412 arrangement, EA402 913-402-000-012 sits between the transducer cable and the IQS900 conditioner input. The complete system length is defined by the TQ4xx integral cable together with the EA402 extension, so the cable is part of the high-frequency measurement path rather than a general control lead.

The FEP coaxial construction and self-locking miniature coaxial connector on EA402 913-402-000-012 keep the extension aligned with the specified measurement chain. Routing, bend radius, connector temperature and the selected environmental variant all belong to the installed cable arrangement.

EA402 extension cable dimensional drawing from the TQ402 TQ412 EA402 IQS900 data sheetClick to view full size
EA402 extension cable dimensional drawing
02

Technical specifications

Brand
Meggitt Vibro-Meter
Product type
EA402 extension cable
Product family
TQ4xx proximity measurement system
Complete model
EA402 913-402-000-012
System role
Extends the probe integral cable to the conditioner input
Sensor family
TQ402 / TQ412 proximity transducers
Conditioner connection
IQS900 signal conditioner input
Cable construction
FEP coaxial extension cable
Cable impedance
70 Ω
Cable outside diameter
Approx. 3.6 mm
Cable minimum bend radius
20 mm
Optional hose minimum bend radius
50 mm
Connector
Self-locking miniature coaxial connector
System length combinations
1 m, 5 m, or 10 m total TQ4xx system length
Total-length rule
TQ4xx integral cable plus EA402 extension cable
Cable / connector temperature
−40 to +200 °C
Transducer system bandwidth
DC to 20 kHz (−3 dB)
Measurement gap families
2 mm or 4 mm system options
Environmental variants
Ex i / Ex nA variants are available within the system family
Optional protection
IP172 interconnection protector option
EMC family
EN 61000-6-2 and EN 61000-6-4 system compliance
03

Installation highlights

Route the coaxial extension

EA402 913-402-000-012 is installed as a controlled cable segment, so the physical route has to preserve the coaxial path from the TQ4xx probe to IQS900.

  1. 01

    Minimum bend radius

    The bare cable route for EA402 913-402-000-012 keeps at least 20 mm bend radius; the optional hose route uses the separate 50 mm value.

  2. 02

    Connector orientation

    Seat the self-locking miniature coaxial connector of EA402 913-402-000-012 into its matching TQ4xx/IQS900 connection before securing the route.

  3. 03

    Thermal route

    The cable and connector limits for EA402 913-402-000-012 are evaluated with the selected probe, protection and environmental variant.

Preserve the cable boundary

The extension is a measurement-path component; installation details determine whether the signal reaches the conditioner as the selected TQ4xx system.

  1. 01

    Do not mix cable types

    EA402 913-402-000-012 uses the EA402 FEP coaxial construction; a general instrument lead does not provide the same cable function.

  2. 02

    Account for total length

    When EA402 913-402-000-012 is added, include the TQ4xx integral cable in the total 1 m, 5 m or 10 m system arrangement.

  3. 03

    Use the protection option correctly

    If an IP172 interconnection protector is specified with EA402 913-402-000-012, its connector and environmental position remain part of the same cable path.

04

System integration

Where the signal travels

EA402 913-402-000-012 occupies the middle of the TQ4xx measurement chain, joining the front-end cable to the conditioner rather than creating a separate field signal.

  1. 01

    Probe side

    The integral cable from TQ402 or TQ412 reaches the EA402 913-402-000-012 extension segment.

  2. 02

    Conditioner side

    The far connector of EA402 913-402-000-012 continues to the IQS900 high-frequency input.

  3. 03

    Measurement output

    IQS900 conditions the proximity signal after the path containing EA402 913-402-000-012; the cable itself is not the controller output stage.

Keep the system combination intact

The TQ4xx system uses defined cable combinations, so EA402 913-402-000-012 is selected together with the probe and conditioner path.

  1. 01

    System length

    The TQ4xx integral cable and EA402 913-402-000-012 extension together make the specified 1 m, 5 m or 10 m system length.

  2. 02

    Environment code

    For an Ex arrangement, the selected EA402 variant, probe and conditioner environment must describe the same installed path around EA402 913-402-000-012.

  3. 03

    Protection position

    An optional IP172 protector can sit at the interconnection involving EA402 913-402-000-012; it does not change the role of the EA402 extension itself.

05

Frequently asked questions

How is EA402 913-402-000-012 placed in the measurement chain?

EA402 913-402-000-012 is the extension segment between the integral cable of a TQ402 or TQ412 transducer and the IQS900 conditioner input. The probe, extension and conditioner must remain one defined TQ4xx signal chain.

Can EA402 913-402-000-012 be treated as a general control cable?

No. EA402 913-402-000-012 is the coaxial extension used by the high-frequency proximity path. Its connector, bend radius and total system length have to remain compatible with the TQ4xx measurement arrangement.

What bend-radius issue should be checked before routing EA402 913-402-000-012?

Keep the EA402 913-402-000-012 cable at or above its 20 mm minimum bend radius. If an optional hose is used, the hose route has its own 50 mm minimum bend radius and should not be treated as the bare-cable value.

Which connection detail matters when fitting EA402 913-402-000-012?

EA402 913-402-000-012 uses a self-locking miniature coaxial connector. The mating connector, cable path and any IP172 interconnection protector must be checked as one interface rather than mixing an unrelated coax connector.

How does the length of EA402 913-402-000-012 affect a TQ4xx system?

The specified system length is the sum of the TQ402/TQ412 integral cable and the EA402 913-402-000-012 extension. Select the documented 1 m, 5 m or 10 m total arrangement instead of adding an arbitrary extension to the probe.

What should be checked when a TQ4xx signal changes after EA402 913-402-000-012 is installed?

Trace the full EA402 913-402-000-012 path from the transducer connector to IQS900, then check the complete cable length, connector lock, bend radius and environment option. A changed output should not be assigned to the extension alone before the whole chain is checked.

06

Company profile

Moore Automation

Moore Automation supplies industrial automation parts to customers worldwide. Each enquiry is assigned to one account manager who keeps the requested model, quantity, destination, lead time and commercial details together throughout the response process.

The team works with manufacturers and suppliers to locate requested parts, confirm availability and provide clear lead-time information. Shipping can be coordinated with recognised carriers, while tracking details and order progress remain available through the same contact.

Dedicated managerOne contact for each enquiry
Lead-time updatesClear timing and tracking details
Global sourcingManufacturer and supplier network
Moore Automation company team and warehouse
08

Contact information

Discuss the exact cable path

ManagerLeoniaModel-led enquiry coordination
Meggitt Vibro-Meter · EA402 extension cableModel reference: EA402 913-402-000-012

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.