Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>VIBRO METER>Meggitt Vibro-Meter EA902 913-902-000-011 | EA902 coaxial extension cable
Meggitt Vibro-Meter EA902 913-902-000-011 | EA902 coaxial extension cable

Meggitt Vibro-Meter EA902 913-902-000-011 | EA902 coaxial extension cable Item NO.: 2921984

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Meggitt Vibro-Meter EA902 913-902-000-011 | EA902 coaxial extension cable
Item NO. 2921984
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category VIBRO METER
Brand OTHER PRODUCTS
Creation Time 2026-10-16

Meggitt Vibro-Meter EA902 913-902-000-011 | EA902 coaxial extension cable
Meggitt Vibro-Meter · TQ942 / EA902 / IQS900 proximity measurement chain

Meggitt Vibro-Meter EA902 913-902-000-011 | EA902 coaxial extension cable

Extends the probe cable to the IQS900 conditioner while retaining the defined chain length

01

Product Overview

Meggitt Vibro-Meter EA902 913-902-000-011 is an EA902 coaxial extension cable in the TQ942 / EA902 / IQS900 proximity measurement chain. It carries the high-frequency probe signal from the TQ942 cable toward the IQS900 conditioner without acting as a separate sensing or output device.

Between the probe and conditioner, EA902 913-902-000-011 forms part of the calibrated 1 m, 5 m or 10 m chain. The probe cable and extension are therefore treated as one total signal length before the IQS900 converts target movement into a voltage or current output.

Routing for EA902 913-902-000-011 has to preserve the coaxial connector, cable bend and selected environmental arrangement. The self-locking miniature coaxial interface joins the two cable sections, while an optional interconnection protector can shield that junction where the system configuration includes it.

EA902 extension-cable mechanical drawing
EA902 extension-cable mechanical drawing
Full-size EA902 extension-cable mechanical drawing×
02

Technical Specifications

Brand
Meggitt Vibro-Meter
Product type
EA902 coaxial extension cable
Product family
TQ942 / EA902 / IQS900
Complete model
EA902 913-902-000-011
System role
Probe-to-conditioner extension segment
Measurement principle
Eddy-current proximity chain
Cable construction
FEP coaxial cable
Cable impedance
70 ohm
Cable outside diameter
Approx. 3.6 mm
Minimum cable bend radius
20 mm
Optional hose bend radius
50 mm
Connector
Self-locking miniature coaxial
Defined chain lengths
1 m, 5 m or 10 m
Cable / connector temperature
-40 to +200 °C
System frequency response
DC to 20 kHz (-3 dB)
Measurement ranges in family
2 mm or 4 mm
Optional junction protection
IP172 interconnection protector
03

Installation Highlights

EA902 913-902-000-011 is a high-frequency measurement cable, so connector seating, cable bend and junction protection directly affect the probe-to-conditioner path.

  1. 01

    Cable and hose bends

    The FEP coaxial section of EA902 913-902-000-011 is routed at or above its 20 mm minimum bend radius. When the flexible stainless-steel protection hose is selected, that section uses the separate 50 mm minimum bend radius.

  2. 02

    Self-locking coaxial joint

    The female and male miniature coaxial connectors of EA902 913-902-000-011 are fully seated before the cable is secured. This keeps the probe response on the defined coaxial path rather than transferring strain into the connector.

  3. 03

    Protected interconnection

    An IP172 protector can enclose the joint associated with EA902 913-902-000-011 when the selected arrangement requires it. The protector surrounds the connection; it does not replace either self-locking coaxial interface.

04

System Integration

EA902 913-902-000-011 occupies the middle of the TQ942 / IQS900 chain: the probe creates the proximity response, the extension carries it, and the conditioner converts it to the monitoring signal.

  1. 01

    Probe-side handoff

    The integral TQ942 lead terminates at the female side of EA902 913-902-000-011. The extension continues the same high-frequency probe circuit without becoming a separate sensing element.

  2. 02

    Conditioner-side handoff

    The male end of EA902 913-902-000-011 connects to the IQS900 high-frequency input. IQS900 then demodulates the probe response and provides the dynamic and quasi-static output used by the receiving channel.

  3. 03

    Defined electrical length

    The TQ942 integral lead and EA902 913-902-000-011 together form the selected 1 m, 5 m or 10 m system length. That combined length is part of the calibrated measurement chain, not only a routing dimension.

05

Frequently Asked Questions

Where does EA902 913-902-000-011 sit in a TQ942 channel?

EA902 913-902-000-011 is the middle cable segment between the TQ942 integral lead and the IQS900 high-frequency input; the probe remains the sensing element and IQS900 remains the conditioner.

Which length must be counted when EA902 913-902-000-011 is installed?

Count the TQ942 integral cable together with EA902 913-902-000-011. Their sum must match the selected 1 m, 5 m or 10 m measurement-chain length.

What routing limit applies to EA902 913-902-000-011?

The bare EA902 913-902-000-011 cable keeps a minimum 20 mm bend radius. If a protective hose is fitted, the hose uses its separate 50 mm minimum.

Can a general coaxial lead replace EA902 913-902-000-011?

No. EA902 913-902-000-011 has the specified 70 ohm FEP coaxial construction and self-locking connector used by the calibrated TQ942 chain.

How is the EA902 913-902-000-011 junction protected?

Where the installation calls for it, an IP172 protector encloses the interconnection involving EA902 913-902-000-011 without changing the cable’s electrical role.

What should be traced if the IQS900 signal changes after fitting EA902 913-902-000-011?

Check the TQ942 connector, the complete EA902 913-902-000-011 route, total cable length and the IQS900 input in that order; this separates a cable-path fault from a conditioner fault.

06

Company Profile

Moore Automation

Moore Automation supplies industrial automation hardware for international projects. Complete product identifiers, quantities, destinations, technical documents and commercial records remain connected from initial review through shipment.

Nameplate photographs, existing drawings and installed-system details can be kept with the complete requested identifier. This gives technical, commercial and logistics records one consistent product reference.

Documented workflowTechnical and order records use the same model reference
Industrial scopeAutomation and machinery-monitoring hardware
Document continuityModels, drawings and shipment records stay linked
Moore Automation company profile imagewww.mvme.cn
Full-size Moore Automation image×
08

Contact Information

Contact Information

Discuss the exact product reference and installed-system requirement with Moore Automation.

ManagerLeonia
Emailsales@mvme.cnWhatsApp+86 180 3017 5807
Moore Automation · EA902 coaxial extension cableModel reference: EA902 913-902-000-011

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.