Serial data route
Two galvanically isolated serial channels carry supported RS-232 or RS-485 messages without sharing the Ethernet media.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Triconex 4610 / 4610X Unified Communication Modules |
| Item NO. | 2915754 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | TRICONEX |
| Brand | TRICONEX |
| Creation Time | 2026-10-10 |
Triconex · Tricon safety systems
Triconex 4610 / 4610X are Unified Communication Modules that place external communications beside the main processors in two Tricon controller generations. The 4610 serves the Tricon v9-v11 platform, while the 4610X occupies a communication position in the 8120X Tricon CX main chassis. In both systems, the module's main responsibility is to exchange controller data with serial hosts, safety-network nodes and the control-network path without moving those interfaces onto a main processor.
Through their isolated serial ports, Triconex 4610 / 4610X carry supported RS-232 or RS-485 messages to the module processor, while the NET interfaces carry Ethernet traffic on a separate physical path. A dedicated fiber connection handles the control network, and the chassis communication bus links the module back to the installed main processors. This separation keeps serial wiring, safety-network media and control-network fiber assigned to different connectors and destinations.
Selection between Triconex 4610 / 4610X follows the installed chassis and the required network medium. The 4610 belongs to the enhanced-performance Tricon chassis and uses the earlier fixed fiber interface arrangement; the 4610X belongs to the 8120X main chassis and accepts the Tricon CX copper or SFP network arrangement. The complete model therefore determines both the backplane connection and the front-panel cable set.
| Technical Item | 4610 | 4610X |
|---|---|---|
| Brand | Triconex | |
| Product Type | Unified Communication Module | |
| Country of Origin | United States | |
| System Platform | Tricon v9-v11 | Tricon CX |
| Compatible Main Chassis | 8120E enhanced-performance chassis | 8120X main chassis |
| Compatible Main Processor | 3009 | 3009X |
| Serial Interfaces | 2 isolated RS-232/RS-485 ports, DB-9 | |
| Serial Speed | Up to 115.2 kbit/s per port; 230.4 kbit/s aggregate | |
| Port Isolation | 500 V DC | |
| Safety Network | 2 fiber Ethernet ports, MT-RJ | 2 copper Ethernet or 2 SFP fiber interfaces |
| Control Network | 2 fiber Ethernet ports, LC | 2 100Base-FX fiber interfaces |
| Network Speed | 100 Mbit/s | 100/1000 Mbit/s safety network |
| HART Pass-through | Not specified | HART 7 compatible |
| Logic Power | Chassis powered | <30 W |
| Operating Temperature | 0...60 °C | 0...55 °C when installed in 8120X |
| Approximate Weight | Chassis module | 1.71 kg |
4610 / 4610X separate serial messaging, safety-network traffic and control-network traffic into dedicated physical interfaces.
Two galvanically isolated serial channels carry supported RS-232 or RS-485 messages without sharing the Ethernet media.
NET ports connect the Tricon controller to permitted safety-network hosts; the media selection must match the specific module generation.
The dedicated fiber control-network pair connects the UCM to the supported Foxboro control-network path.
4610 / 4610X sit between the Tricon main processors and external communication hosts, so chassis generation, slot position and cable media must be matched together.
The chassis communication bus passes controller data between the UCM and the three installed main processors.
4610 belongs with the enhanced-performance Tricon chassis, whereas 4610X belongs with the 8120X Tricon CX chassis.
Copper and fiber safety-network choices are selected at the module ports; they are not interchangeable with the separate control-network fiber connection.
No. The two modules belong to different chassis generations even though both are UCMs. Confirm the main chassis and main-processor model before ordering.
Provide the electrical mode, baud rate, protocol role and DB-9 pin assignment. This prevents an RS-232 requirement from being quoted as an RS-485 connection.
State whether each required path is the safety network or the control network, then state copper or fiber and the connector type. The port group determines the permitted medium.
Communication modules occupy defined COM positions and communicate through the chassis bus. A correct front-panel connector list does not make a module compatible with the wrong backplane generation.
Record the complete model, chassis, port labels, cable destinations, IP settings and serial parameters. Those details keep the replacement wiring and configuration aligned.
No. Link state only confirms the physical path. Module status, processor communication and configured protocol sessions must also be normal.
MOORE AUTOMATION
https://www.mvme.cn/Moore Automation supports international requests for controller communication hardware while preserving the complete manufacturer model and chassis generation through quotation, order handling and shipment. The supply record keeps 4610 separate from 4610X so the requested communication module is not reduced to a generic UCM.
| Brand | Model | Brand | Model | Brand | Model |
|---|---|---|---|---|---|
| Siemens | 6ES7288-1SR20-0AA1 | Siemens | 6ES7288-1SR40-0AA1 | Siemens | 6ES7288-1ST20-0AA1 |
| GE Excitation | IS220PTURH1A | GE Excitation | IS220PAICH1A | GE Excitation | IS220PDIOH1A |
| GE Fanuc | IC670GBI001 | GE Fanuc | IC670GBI102 | GE Fanuc | IC670FBI001 |
| ABB Robotics | 3HAC043569-004 | ABB Robotics | 3HAC058991-003 | ABB Robotics | 3HAC034647-003 |
| Allen-Bradley | 25B-D4P0N104 | Allen-Bradley | 25B-B5P0N104 | Allen-Bradley | 25B-D2P3N104 |
| Bently Nevada | 330130-040-00-05 | Bently Nevada | 330130-080-13-05 | Bently Nevada | 3500/05-01-01-00-00-01 |
| ABB | PM891K01 | ABB | PM863K02 | ABB | PM866AK01 |
| TRICONEX | 8310 | TRICONEX | 8120E | TRICONEX | 4351B |
| B&R | X20CP1586 | B&R | X20CP1583 | B&R | X20CP1684 |
| Motorola | MVME162-212 | Motorola | MVME147-011 | Motorola | MVME5500-0161 |
| Siemens | 6ES7288-1SR30-0AA1 | Siemens | 6ES7288-1SR60-0AA1 | Siemens | 6ES7288-1ST30-0AA1 |
| GE Excitation | IS420PVIBH1B | GE Excitation | IS220PAICH2A | GE Excitation | IS220PDIAH1A |
| GE Fanuc | IC670GBI002 | GE Fanuc | IC670PBI001 | GE Fanuc | IC670MFP100 |
| ABB Robotics | 3HAC058991-004 | ABB Robotics | 3HAC031184-003 | ABB Robotics | 3HAC055448-003 |
| Allen-Bradley | 25B-D030N104 | Allen-Bradley | 25B-D1P4N104 | Allen-Bradley | 25B-D6P0N104 |
| Bently Nevada | 330130-046-00-06 | Bently Nevada | 330130-085-03-05 | Bently Nevada | 3500/15 106M1079-01 |
| ABB | PM862K01 | ABB | PM891K02 | ABB | PM866AK02 |
| TRICONEX | 8403X-1 | TRICONEX | 3009 | TRICONEX | 8312 |
| B&R | X20CP1585 | B&R | X20CP3686X | B&R | X20CP1684X |
| Motorola | MVME162-520 | Motorola | MVME147-013 | Motorola | MVME6100 |
Send the complete model and requested quantity for an exact enquiry record.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found