Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>VIBRO METER>Meggitt Vibro-Meter RLC16 200-570-000-012 / RLC16 200-570-000-014 | VM600 16-channel relay card
Meggitt Vibro-Meter RLC16 200-570-000-012 / RLC16 200-570-000-014 | VM600 16-channel relay card

Meggitt Vibro-Meter RLC16 200-570-000-012 / RLC16 200-570-000-014 | VM600 16-channel relay card Item NO.: 2919901

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Meggitt Vibro-Meter RLC16 200-570-000-012 / RLC16 200-570-000-014 | VM600 16-channel relay card
Item NO. 2919901
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category VIBRO METER
Brand OTHER PRODUCTS
Creation Time 2026-10-15

Meggitt Vibro-Meter RLC16 200-570-000-012 / RLC16 200-570-000-014 | VM600 16-channel relay card variant group

Meggitt Vibro-Meter VM600 industrial monitoring hardware

Meggitt Vibro-Meter RLC16 200-570-000-012 / RLC16 200-570-000-014 | VM600 16-channel relay card

VM600 · adds relay contacts for alarm and status actions in a VM600 monitoring or protection rack

01

Product Information

Meggitt Vibro-Meter RLC16 200-570-000-012 / RLC16 200-570-000-014 is a VM600 16-channel relay card variant group. It adds relay contacts to the rack so configured alarm and status conditions can be presented to external circuits.

Each RLC16 200-570-000-012 / RLC16 200-570-000-014 card provides sixteen SPDT relay channels arranged for field termination at the card connectors. The relay contacts are driven by the VM600 configuration, while a separate common-circuit fault relay reports card-level fault status.

The relay wiring on RLC16 200-570-000-012 / RLC16 200-570-000-014 is separate from the measurement input path. The VM600 configuration drives each contact from the alarm or status point assigned to that relay channel.

VM600 relay and protection card technical illustration
02

Technical Data

Technical item Specification
Brand Meggitt Vibro-Meter
Product type 16-channel relay card
Product family VM600 RLC16
Variant A 200-570-000-012
Variant B 200-570-000-014
Relay channels 16 SPDT relays
Relay contacts Changeover contacts per channel
Fault relay Common-circuit fault relay
Field function Alarm and status switching
Rack connection VM600 backplane
Connector set Relay termination
Relay logic Configured alarm logic
Electrical role Contact output, not measurement input
Contact arrangement 1 COM + 1 NC + 1 NO per relay
Rated voltage 250 VAC
Rated current 5 AAC
Breaking capacity 1250 VA maximum
Operate/release/bounce Typically 8 / 8 / 6 ms
Dielectric strength 1000 VAC open contacts; 4000 VAC contact-to-coil
Mechanical life 15 × 10^6 operations
Electrical life >10^5 operations
Power supply +5 VDC; 40 mA × 16 per relay
Connector allocation J1 RL1–RL6; J2 RL6–RL11; J3 RL11–RL16
Environment −25 to 65°C; 0–90% RH
Physical 6U × 20 mm × 125 mm; approximately 0.30 kg
03

Product Functions: Alarm Relay Outputs

RLC16 200-570-000-012 / RLC16 200-570-000-014 converts configured alarm states into relay contact actions for external circuits.

01

Sixteen channels

The sixteen SPDT relay channels provide separate contact paths for configured points.

02

Common fault

The common-circuit fault relay reports a card-level fault condition.

03

Field contact

External alarm wiring connects to the assigned relay contacts rather than to measurement inputs.

04

Diagnostics and Protection: Relay State

RLC16 200-570-000-012 / RLC16 200-570-000-014 keeps alarm contact state and common-circuit fault indication as distinct diagnostic paths.

01

Alarm state

A configured alarm changes the relay assigned to that alarm point.

02

Fault state

The common fault relay identifies a card-level circuit fault separately from a point alarm.

03

Rack status

The VM600 rack carries the relay card status into the monitoring configuration.

05

Product Questions

How many relay outputs are available on RLC16 200-570-000-012 / RLC16 200-570-000-014?

RLC16 200-570-000-012 / RLC16 200-570-000-014 provides sixteen SPDT relay channels for configured alarm or status points. The common-circuit fault relay is a separate card-level indication and is not counted as one of the sixteen point relays.

What is the difference between a point alarm and the fault relay on RLC16 200-570-000-012 / RLC16 200-570-000-014?

A point alarm changes the relay assigned to that alarm point. The common-circuit fault relay reports a card-level fault condition, so the two contacts answer different diagnostic questions.

Are the terminals on RLC16 200-570-000-012 / RLC16 200-570-000-014 measurement inputs?

No. RLC16 200-570-000-012 / RLC16 200-570-000-014 is a relay card and its terminals are used for contact outputs. Measurement signals enter through the associated VM600 monitoring or protection cards.

How should RLC16 200-570-000-012 / RLC16 200-570-000-014 be wired to an external alarm circuit?

Use the assigned SPDT contact terminals for each configured point and keep the common fault relay on its separate circuit. The external load must match the relay contact arrangement used by the installation.

Why are 200-570-000-012 and 200-570-000-014 shown together in RLC16 200-570-000-012 / RLC16 200-570-000-014?

RLC16 200-570-000-012 / RLC16 200-570-000-014 contains two supplied RLC16 identifiers, and each full PNR remains visible as its own variant within the relay-card group.

What should be inspected when an RLC16 alarm output appears stuck?

Compare the configured point with the actual relay contact terminals, then check the common-circuit fault indication on RLC16 200-570-000-012 / RLC16 200-570-000-014. This separates a point assignment issue from a card-level fault path.

06

Customer Support

Moore Automation

https://www.mvme.cn/

Moore Automation provides a direct contact route for questions about VM600 hardware, configuration strings and field connections.

Named managerThe manager, email and WhatsApp channels remain alongside the product details so the customer can send a complete request.
Email channelThe manager, email and WhatsApp channels remain alongside the product details so the customer can send a complete request.
WhatsApp channelThe manager, email and WhatsApp channels remain alongside the product details so the customer can send a complete request.
www.mvme.cn

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.