Sixteen channels
The sixteen SPDT relay channels provide separate contact paths for configured points.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Meggitt Vibro-Meter RLC16 200-570-000-012 / RLC16 200-570-000-014 | VM600 16-channel relay card |
| Item NO. | 2919901 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | VIBRO METER |
| Brand | OTHER PRODUCTS |
| Creation Time | 2026-10-15 |
Meggitt Vibro-Meter VM600 industrial monitoring hardware
VM600 · adds relay contacts for alarm and status actions in a VM600 monitoring or protection rack
Meggitt Vibro-Meter RLC16 200-570-000-012 / RLC16 200-570-000-014 is a VM600 16-channel relay card variant group. It adds relay contacts to the rack so configured alarm and status conditions can be presented to external circuits.
Each RLC16 200-570-000-012 / RLC16 200-570-000-014 card provides sixteen SPDT relay channels arranged for field termination at the card connectors. The relay contacts are driven by the VM600 configuration, while a separate common-circuit fault relay reports card-level fault status.
The relay wiring on RLC16 200-570-000-012 / RLC16 200-570-000-014 is separate from the measurement input path. The VM600 configuration drives each contact from the alarm or status point assigned to that relay channel.
| Technical item | Specification |
|---|---|
| Brand | Meggitt Vibro-Meter |
| Product type | 16-channel relay card |
| Product family | VM600 RLC16 |
| Variant A | 200-570-000-012 |
| Variant B | 200-570-000-014 |
| Relay channels | 16 SPDT relays |
| Relay contacts | Changeover contacts per channel |
| Fault relay | Common-circuit fault relay |
| Field function | Alarm and status switching |
| Rack connection | VM600 backplane |
| Connector set | Relay termination |
| Relay logic | Configured alarm logic |
| Electrical role | Contact output, not measurement input |
| Contact arrangement | 1 COM + 1 NC + 1 NO per relay |
| Rated voltage | 250 VAC |
| Rated current | 5 AAC |
| Breaking capacity | 1250 VA maximum |
| Operate/release/bounce | Typically 8 / 8 / 6 ms |
| Dielectric strength | 1000 VAC open contacts; 4000 VAC contact-to-coil |
| Mechanical life | 15 × 10^6 operations |
| Electrical life | >10^5 operations |
| Power supply | +5 VDC; 40 mA × 16 per relay |
| Connector allocation | J1 RL1–RL6; J2 RL6–RL11; J3 RL11–RL16 |
| Environment | −25 to 65°C; 0–90% RH |
| Physical | 6U × 20 mm × 125 mm; approximately 0.30 kg |
RLC16 200-570-000-012 / RLC16 200-570-000-014 converts configured alarm states into relay contact actions for external circuits.
The sixteen SPDT relay channels provide separate contact paths for configured points.
The common-circuit fault relay reports a card-level fault condition.
External alarm wiring connects to the assigned relay contacts rather than to measurement inputs.
RLC16 200-570-000-012 / RLC16 200-570-000-014 keeps alarm contact state and common-circuit fault indication as distinct diagnostic paths.
A configured alarm changes the relay assigned to that alarm point.
The common fault relay identifies a card-level circuit fault separately from a point alarm.
The VM600 rack carries the relay card status into the monitoring configuration.
RLC16 200-570-000-012 / RLC16 200-570-000-014 provides sixteen SPDT relay channels for configured alarm or status points. The common-circuit fault relay is a separate card-level indication and is not counted as one of the sixteen point relays.
A point alarm changes the relay assigned to that alarm point. The common-circuit fault relay reports a card-level fault condition, so the two contacts answer different diagnostic questions.
No. RLC16 200-570-000-012 / RLC16 200-570-000-014 is a relay card and its terminals are used for contact outputs. Measurement signals enter through the associated VM600 monitoring or protection cards.
Use the assigned SPDT contact terminals for each configured point and keep the common fault relay on its separate circuit. The external load must match the relay contact arrangement used by the installation.
RLC16 200-570-000-012 / RLC16 200-570-000-014 contains two supplied RLC16 identifiers, and each full PNR remains visible as its own variant within the relay-card group.
Compare the configured point with the actual relay contact terminals, then check the common-circuit fault indication on RLC16 200-570-000-012 / RLC16 200-570-000-014. This separates a point assignment issue from a card-level fault path.
https://www.mvme.cn/
Moore Automation provides a direct contact route for questions about VM600 hardware, configuration strings and field connections.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found