The AS3 module provides the program executed by KDA3.2-050-3-A00-W1.
Rexroth
Indramat
KDA 3 · 50 A ANALOG DRIVE
Bosch Rexroth KDA3.2-050-3-A00-W1 KDA 3 Modular Main Spindle Drive
Product Summary
50 A / 300 V DCBosch Rexroth Indramat KDA3.2-050-3-A00-W1 is a 50 A modular KDA 3 main spindle drive for Indramat 2AD asynchronous and 1MB frameless spindle motors. It receives a ±10 V speed command through the A interface, processes motor-feedback signals and switches 300 V DC-bus energy from the supply module into the controlled power delivered to the main spindle motor.
The control structure of KDA3.2-050-3-A00-W1 separates operating data from the power hardware. The AS3 programming module stores the operating software together with drive-specific and application-specific parameters, while the serial PC connection supports parameter storage and loading without taking over the real-time analog speed-command function.
Heat from KDA3.2-050-3-A00-W1 follows two paths. Internal electronics loss enters the sealed enclosure, whereas most power-stage heat passes through the rear heatsink and is removed by the W1 blower and air duct outside the enclosure. The published cooling arrangement specifies approximately 32 l/s airflow with a maximum pressure requirement of 30 Pa.
Specification Details
16 verified rows| Brand | Bosch Rexroth Indramat |
|---|---|
| Product name | KDA 3 modular main spindle drive |
| Series / design | KDA3.2 |
| Type current | 50 A |
| DC-bus voltage class | 300 V DC |
| Command interface | ±10 V analog speed command |
| Motor feedback option | Standard feedback input |
| Additional encoder input | None |
| Auxiliary interface | None |
| Cooling option | W1 forced cooling |
| Heatsink airflow | Approx. 32 l/s |
| Maximum blower pressure | 30 Pa |
| Programming module | AS3 |
| Housing width / depth | 150 mm / 325 mm |
| Device mass | 16.6 kg |
| Mounting orientation | Vertical |
Programming Module Connects Software, Motor Data and Machine Settings
Stored operating dataThe AS3 programming module of KDA3.2-050-3-A00-W1 contains the operating software plus two parameter sets: drive-specific data describing the motor/drive combination and application-specific data describing the machine function.
Because the data is carried in the programming module, KDA3.2-050-3-A00-W1 keeps parameter storage physically separate from its 50 A power stage. The serial interface can transfer these parameters to a PC for storage or loading.
Motor and drive characteristics define the electrical operating behavior.
Machine-specific speed, position and process settings complete the operating context.
Internal and External Heat Follow Separate Cooling Routes
Cooling methodThe W1 arrangement directs most power-stage heat outside the control enclosure while keeping electronics inside the sealed area.
Electronics contribute enclosure heat
The internal loss of KDA3.2-050-3-A00-W1 remains inside the cabinet and belongs in the enclosure thermal calculation.
Rear heatsink carries the larger heat share
The power-stage heatsink projects into the external duct so its heat does not all enter the electronics compartment.
Blower and duct maintain the external path
The W1 system uses about 32 l/s airflow and a maximum 30 Pa pressure requirement across the defined cooling route.
Questions & Answers
06 practical checks01What does the A interface mean on KDA3.2-050-3-A00-W1?
The A interface of KDA3.2-050-3-A00-W1 accepts a ±10 V analog speed command; it is distinct from the serial parameter-storage connection.
02Where are parameters stored for KDA3.2-050-3-A00-W1?
The AS3 programming module of KDA3.2-050-3-A00-W1 stores operating software, drive-specific parameters and application-specific parameters.
03How should the cooling duct be arranged for KDA3.2-050-3-A00-W1?
The W1 blower of KDA3.2-050-3-A00-W1 must move air through the rear heatsink duct without mixing the external heat path into the sealed electronics compartment.
04Which airflow data belongs to KDA3.2-050-3-A00-W1?
The cooling diagram for KDA3.2-050-3-A00-W1 specifies approximately 32 l/s with a maximum pressure requirement of 30 Pa.
05How does power reach the motor from KDA3.2-050-3-A00-W1?
KDA3.2-050-3-A00-W1 receives 300 V DC-bus power from the supply module and switches it through the inverter to the main spindle motor power cable.
06Why are the motor power and feedback cables separate on KDA3.2-050-3-A00-W1?
The motor-power cable of KDA3.2-050-3-A00-W1 carries inverter output, while the feedback cable returns rotor information to the control electronics; their signal and voltage roles differ.