Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BOSCH >Bosch Rexroth KDA3.2-050-3-A00-W1 KDA 3 Modular Main Spindle Drive
Bosch Rexroth KDA3.2-050-3-A00-W1 KDA 3 Modular Main Spindle Drive

Bosch Rexroth KDA3.2-050-3-A00-W1 KDA 3 Modular Main Spindle Drive Item NO.: 2944327

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bosch Rexroth KDA3.2-050-3-A00-W1 KDA 3 Modular Main Spindle Drive
Item NO. 2944327
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BOSCH
Brand BOSCH
Creation Time 2026-11-23

Bosch Rexroth KDA3.2-050-3-A00-W1 KDA 3 Modular Main Spindle Drive
Bosch
Rexroth
Indramat

KDA 3 · 50 A ANALOG DRIVE

Bosch Rexroth KDA3.2-050-3-A00-W1 KDA 3 Modular Main Spindle Drive

KDA3.250 A / 300 V DC

Product Summary

50 A / 300 V DC

Bosch Rexroth Indramat KDA3.2-050-3-A00-W1 is a 50 A modular KDA 3 main spindle drive for Indramat 2AD asynchronous and 1MB frameless spindle motors. It receives a ±10 V speed command through the A interface, processes motor-feedback signals and switches 300 V DC-bus energy from the supply module into the controlled power delivered to the main spindle motor.

The control structure of KDA3.2-050-3-A00-W1 separates operating data from the power hardware. The AS3 programming module stores the operating software together with drive-specific and application-specific parameters, while the serial PC connection supports parameter storage and loading without taking over the real-time analog speed-command function.

Heat from KDA3.2-050-3-A00-W1 follows two paths. Internal electronics loss enters the sealed enclosure, whereas most power-stage heat passes through the rear heatsink and is removed by the W1 blower and air duct outside the enclosure. The published cooling arrangement specifies approximately 32 l/s airflow with a maximum pressure requirement of 30 Pa.

Specification Details

16 verified rows
AttributeKDA3.2-050-3-A00-W1
Brand Bosch Rexroth Indramat
Product name KDA 3 modular main spindle drive
Series / design KDA3.2
Type current 50 A
DC-bus voltage class 300 V DC
Command interface ±10 V analog speed command
Motor feedback option Standard feedback input
Additional encoder input None
Auxiliary interface None
Cooling option W1 forced cooling
Heatsink airflow Approx. 32 l/s
Maximum blower pressure 30 Pa
Programming module AS3
Housing width / depth 150 mm / 325 mm
Device mass 16.6 kg
Mounting orientation Vertical

Programming Module Connects Software, Motor Data and Machine Settings

Stored operating data

The AS3 programming module of KDA3.2-050-3-A00-W1 contains the operating software plus two parameter sets: drive-specific data describing the motor/drive combination and application-specific data describing the machine function.

Because the data is carried in the programming module, KDA3.2-050-3-A00-W1 keeps parameter storage physically separate from its 50 A power stage. The serial interface can transfer these parameters to a PC for storage or loading.

Operating software

The AS3 module provides the program executed by KDA3.2-050-3-A00-W1.

Drive parameters

Motor and drive characteristics define the electrical operating behavior.

Application parameters

Machine-specific speed, position and process settings complete the operating context.

Internal and External Heat Follow Separate Cooling Routes

Cooling method

The W1 arrangement directs most power-stage heat outside the control enclosure while keeping electronics inside the sealed area.

INTERNAL

Electronics contribute enclosure heat

The internal loss of KDA3.2-050-3-A00-W1 remains inside the cabinet and belongs in the enclosure thermal calculation.

EXTERNAL

Rear heatsink carries the larger heat share

The power-stage heatsink projects into the external duct so its heat does not all enter the electronics compartment.

AIRFLOW

Blower and duct maintain the external path

The W1 system uses about 32 l/s airflow and a maximum 30 Pa pressure requirement across the defined cooling route.

Questions & Answers

06 practical checks
01What does the A interface mean on KDA3.2-050-3-A00-W1?

The A interface of KDA3.2-050-3-A00-W1 accepts a ±10 V analog speed command; it is distinct from the serial parameter-storage connection.

02Where are parameters stored for KDA3.2-050-3-A00-W1?

The AS3 programming module of KDA3.2-050-3-A00-W1 stores operating software, drive-specific parameters and application-specific parameters.

03How should the cooling duct be arranged for KDA3.2-050-3-A00-W1?

The W1 blower of KDA3.2-050-3-A00-W1 must move air through the rear heatsink duct without mixing the external heat path into the sealed electronics compartment.

04Which airflow data belongs to KDA3.2-050-3-A00-W1?

The cooling diagram for KDA3.2-050-3-A00-W1 specifies approximately 32 l/s with a maximum pressure requirement of 30 Pa.

05How does power reach the motor from KDA3.2-050-3-A00-W1?

KDA3.2-050-3-A00-W1 receives 300 V DC-bus power from the supply module and switches it through the inverter to the main spindle motor power cable.

06Why are the motor power and feedback cables separate on KDA3.2-050-3-A00-W1?

The motor-power cable of KDA3.2-050-3-A00-W1 carries inverter output, while the feedback cable returns rotor information to the control electronics; their signal and voltage roles differ.

Global Industrial Component Services

Moore Automation

Moore Automation Limited

https://www.mvme.cn/

Moore Automation Limited supports international enquiries for industrial automation, motion and drive components. Exact model identities and requested documentation remain attached to each enquiry line.

Commercial coordination covers quotation information, customer communication and shipment status through one named contact.

Industrial drive supplyExact model recordsInternational coordinationShipment status support

Suggested Products

60 model references
ABB ACS355-03E-05A6-4
Bently Nevada 330425-01-05
Allen-Bradley 1775-L4
GE IC755CKW10CDM
B&R 8BVI0440HWD0.000-1
Siemens 6ES7511-1TK01-0AB0
ABB ACS355-03E-07A3-4
Bently Nevada 330500-00-00
Allen-Bradley 1775-LP8
GE IC695CPE302
B&R 8B0K1650HW00.000-1
Siemens 6ES7513-1RL00-0AB0
ABB ACS355-03E-08A8-4
Bently Nevada 330500-07-00
Allen-Bradley 1775-LPA
GE IC695CPE305
B&R 8B0C0320HC00.002-1
Siemens 6ES7515-2RN03-0AB0
ABB ACS355-03E-12A5-4
Bently Nevada 330525-00
Allen-Bradley 1775-ME4
GE IC695CPE310
B&R 8EI013HWS10.0600-1
Siemens 6ES7517-3HP00-0AB0
ABB ACS355-03E-15A6-4
Bently Nevada 330701-00-10-10-02-00
Allen-Bradley 1775-ME8
GE IC695CPE330
B&R 8EI2X2HWD10.0600-1
Siemens 6ES7518-4JP00-0AB0
ABB ACS355-03E-23A1-4
Bently Nevada 330701-00-20-10-02-00
Allen-Bradley 1775-MEAA
GE IC695CPE400
B&R 8BAC0120.000-1
Siemens 6ES7521-1BH10-0AA0
ABB ACS355-03E-31A0-4
Bently Nevada 330703-000-050-10-02-00
Allen-Bradley 1775-MED
GE IC695CPL410
B&R 4PPC50.101E-13B
Siemens 6ES7521-1BL00-0AB0
ABB ACS880-01-017A-3
Bently Nevada 330704-0-50-10-02-05
Allen-Bradley 1775-MEF
GE IC695CPS400
B&R 4PPC50.0702-10B
Siemens 6ES7521-1FH00-0AA0
ABB ACS880-01-025A-3
Bently Nevada 330705-02-18-10-02-00
Allen-Bradley 1775-P1
GE IC695CPU310
B&R 4PPC70.101E-20B
Siemens 6ES7521-7EH00-0AB0
ABB ACS880-01-032A-3
Bently Nevada 330706-005-046-10-02-00
Siemens 6ES7288-1SR20-0AA1
ABB PM863K02
Bently Nevada 330130-040-00-05
Allen-Bradley 1734-OW4
Contact DetailsStart an enquiry
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.