Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>GE>GE Fanuc IC695PSD040M RX3i 24 VDC Power Supply
GE Fanuc IC695PSD040M RX3i 24 VDC Power Supply

GE Fanuc IC695PSD040M RX3i 24 VDC Power Supply Item NO.: 2945592

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name GE Fanuc IC695PSD040M RX3i 24 VDC Power Supply
Item NO. 2945592
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-11-27

GE Fanuc IC695PSD040M RX3i 24 VDC Power Supply
GE FanucPACSystems RX3i power
Single-slot forty-watt DC backplane supply

GE Fanuc IC695PSD040M RX3i 24 VDC Power Supply

Input24 VDC
Output40 W
SlotSingle
01
Product record

Item Description

GE Fanuc IC695PSD040M is a forty-watt 24 VDC input power supply for the PACSystems RX3i universal backplane. It converts the external DC source into the regulated backplane rails used by the controller and installed I/O modules.

Power enters IC695PSD040M at the field terminal, passes through input protection and regulation, and is divided into the RX3i 5.1 VDC, 3.3 VDC and relay-power paths. Available capacity is shared by every module served by that supply, so the backplane load calculation belongs to the complete rack.

Front indications on IC695PSD040M distinguish input presence, power-supply health and output status. The module is a single-supply design and does not provide the load-sharing and redundancy functions of the RX3i multi-purpose power-supply family.

02
Verified model data

Product Parameters

Model
IC695PSD040M
Brand
GE Fanuc / Emerson
Product type
RX3i DC power supply
Input nominal
24 VDC
Starting input range
18 to 30 VDC
Running input range
12 to 30 VDC
Maximum input power
60 W at full load
Maximum output power
40 W
Backplane outputs
5.1 VDC, 3.3 VDC and 24 V relay power
Inrush current
4 A for up to 100 ms
Ride-through
10 ms
Installation
Single slot in RX3i universal backplane
Load sharing
Not supported
Redundancy
Not supported
Revision identity
M retained as the exact supply revision
03
Product operation

Backplane Power Path

External 24 VDC is converted into several rails whose combined loading cannot exceed the supply capacity.

DC entry

The field source reaches the supply input through the module terminal and protection stage.

Regulation

The power stage converts the input into the regulated rails required by RX3i electronics.

Rail distribution

The backplane carries 5.1 VDC and 3.3 VDC to logic loads and provides the relay-power path where applicable.

Rack budget

Every installed module contributes current to the same power calculation for the served backplane segment.

The input source does not feed the installed modules directly; regulation and backplane distribution sit between them. A correct rack assessment therefore follows each module load to its rail instead of comparing the input rating with one combined output number.

04
System behavior

Supply Supervision

Indications and power-fail signaling show whether input energy and regulated outputs remain inside the operating boundary.

Input state

The power indication confirms that the external DC source reaches the module.

Output state

Supply electronics monitor the regulated rails rather than only the presence of input voltage.

Power-fail signal

A falling input condition is reported early enough for the controller to handle the power transition.

Recovery

After input returns, the rails must stabilize before the rack can complete a normal startup.

Input presence, regulated-output health and the controller power transition are related but separate states. Reading them in sequence prevents a restored field source from being treated as proof that every backplane rail and controller function has recovered.

05
Practical model checks

Product Guidance

Why must the complete rack load be calculated for IC695PSD040M?

The 40 W rating is shared across the backplane rails. Add the published 5.1 V, 3.3 V and relay-power demands of every installed module instead of comparing only total module count.

Can two IC695PSD040M supplies be paralleled for redundancy?

No. IC695PSD040M does not support the load-sharing and redundancy arrangement used by the multi-purpose RX3i supplies.

What should be measured when IC695PSD040M powers down under load?

Measure input voltage at the module during startup and peak load, confirm conductor and terminal condition, then compare the rack demand with each output-rail capacity.

Why can relay outputs drop before the RX3i controller fully stops on IC695PSD040M power loss?

The 24 V relay-power path can respond differently from the logic rails during an input interruption. Review the relay module and field-load behavior for the actual outage duration.

What information belongs with an IC695PSD040M replacement request?

Include the complete M label, backplane size, input source, rack module list and current power-budget calculation.

How should IC695PSD040M be checked after installation?

Verify terminal polarity and torque, input voltage, front indicators, controller startup and the absence of power-supply faults under the maximum expected rack load.

06
Moore Automation

Power-Supply Matching Support

Moore Automation Limited

https://www.mvme.cn/

Moore Automation records the exact supply revision together with backplane, input-source and rack-load information for review.

A single account contact coordinates documentation requests, quotation details and shipment updates.

Input source recordedRack load reviewedRevision identity keptShipment coordination
07
Separate product records

Similar Models

Siemens6ES7288-3AQ02-0AA0
GEIC670CHS002
Allen-Bradley1769-L32E
Bently Nevada330101-00-08-05-02-05
B&RX20DI4372
ABBPM564-RP-ETH
MotorolaMVME162-510A
FoxboroRH102AG
Bosch RexrothHCS03.1E-W0280-A-05-NNBV
Emerson5X00070G03
Vibro-Meter200-595-072-122
Triconex4352B
YokogawaADV151-P60/D5A00
Woodward8440-2260
ProSoftAN-X2-AB-DHRIO
Emerson EPROA6110
HIMAF8650E
ICS TriplexTC-201-02-15M0
HoneywellCC-SCMB05
Siemens6ES7288-3AQ04-0AA0
GEIC670CHS003
Allen-Bradley1769-L35E
Bently Nevada330101-00-08-10-02-00
B&RX20DI4760
ABBPM564-RP-ETH-AC
MotorolaMVME162-512A1
FoxboroFBM217
Bosch RexrothHCS03.1E-W0350-A-05-NNBV
Emerson5X00453G01
Vibro-Meter200-595-046-114
Triconex3501E
YokogawaAAV144-SK0
WoodwardeasYgen-3200XT
ProSoftRLX2-IHNF-E
Emerson EPROA6210
HIMAF8651X
ICS TriplexT8110B
HoneywellFC-TSDI-16UNI
Siemens6ES7288-3AM03-0AA0
GEIC670CHS004
Allen-Bradley1769-L36ER
Bently Nevada330101-00-08-10-02-05
B&RX20DI9753
ABBPM554-TP-ETH
MotorolaMVME162-522A
FoxboroRH101DF
Bosch RexrothHMS01.1N-W0020-A-07-NNNN
Emerson5X00500G01
Vibro-Meter200-595-100-031
Triconex3502E
YokogawaPW482-50
Woodward8440-2167
ProSoftPLX51-HART-4I
Emerson EPROA6220
HIMAF8652X
ICS TriplexT8151B
HoneywellFC-TSRO-0824
Siemens6ES7288-3AM06-0AA0
GEIC670TBM001
Allen-Bradley1769-L23E-QB1B

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.