Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>GE>GE Fanuc IC695FTB001-AA Fiber I/O Terminal Block
GE Fanuc IC695FTB001-AA Fiber I/O Terminal Block

GE Fanuc IC695FTB001-AA Fiber I/O Terminal Block Item NO.: 2945446

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name GE Fanuc IC695FTB001-AA Fiber I/O Terminal Block
Item NO. 2945446
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-11-26

GE Fanuc IC695FTB001-AA Fiber I/O Terminal Block

GE Fanuc · PACSystems RX3i PACMotion

GE Fanuc IC695FTB001-AA Fiber I/O Terminal Block

A DIN-rail terminal block linking PACMotion controller I/O to field devices over full-duplex fiber.

01 · ID

Hardware Details

GE Fanuc IC695FTB001-AA is a DIN-rail Fiber I/O Terminal Block for a PACMotion PMM335 system. It moves 5 V, 24 V and analog I/O information between the motion controller and field devices across a full-duplex fiber link rather than routing all signals directly to the rack.

The configurable terminals of IC695FTB001-AA can serve overtravel, home, touch-probe, quadrature-encoder, cam and general-purpose functions. Two analog output paths can command compatible analog servos, while optical isolation separates the remote terminal block from the controller-side electrical environment.

A 19.2–28.8 VDC source powers IC695FTB001-AA, and the complete fiber path can extend to 100 m. Status indicators and encoder open-wire or loss diagnostics report conditions locally; if communication is lost, the terminal outputs move to their configured safe state instead of retaining an undefined command.

02 · DATA

System Specifications

Technical Item IC695FTB001-AA
Brand GE Fanuc
Product Type PACMotion Fiber I/O Terminal Block
Brand Country United States
Controller Association PACMotion PMM335
Mounting DIN rail
Communication Full-duplex fiber
Maximum Fiber Distance 100 m
Input Supply 19.2–28.8 VDC
24 V Output Capacity 0.5 A total
Field Functions Overtravel, home, touch probe, encoder, cam and general purpose
Analog Outputs Two paths for compatible analog servo commands
Isolation Optical isolation
Diagnostics Open-wire / loss-of-encoder and communication status
Communication-Loss Behavior Outputs move to configured safe state
03 · CORE

Fiber Motion I/O Exchange

The IC695FTB001-AA fiber link extends motion-related I/O without carrying the field conductors back to the controller rack.

Stage 01

Field State

Sensors and encoder circuits enter through the terminal-block connections.

Stage 02

Local Interface

The FTB conditions the assigned digital, encoder and analog paths.

Stage 03

Fiber Transfer

Full-duplex optical communication carries the I/O record up to 100 m.

Stage 04

Motion Control

The PMM335 uses the transferred states and sends updated output commands back to the FTB.

Explanation 01

Remote Electrical Domain

The terminal block conditions field signals at the machine and communicates optically with the motion controller. Fiber provides electrical separation, while local 24 VDC still supplies the remote I/O circuits.

Explanation 02

Bidirectional Record

Sensor and encoder states travel toward the PMM335; output and analog-servo commands travel back to the FTB. Full duplex allows these directions to operate on the same optical connection.

Explanation 03

Distance and Integrity

The documented 100 m path is a maximum link distance, not permission to ignore connector condition or fiber routing. Optical loss can interrupt every assigned function at the remote block.

The fiber link provides the communication path, but the remote block still needs its own valid 24 VDC supply for field-side operation.

04 · CORE

Terminal Functions and Communication-Loss State

Terminal assignments on IC695FTB001-AA connect motion events to defined controller functions.

Stage 01

Assign

Configuration identifies a terminal as overtravel, home, probe, encoder, cam or general I/O.

Stage 02

Monitor

Local indicators and diagnostics expose link and encoder-path conditions.

Stage 03

Command

Digital or analog outputs follow the controller’s assigned function during normal communication.

Stage 04

Protect

After communication loss, configured outputs move to their defined safe state.

Explanation 01

Configuration Defines Meaning

A physical terminal can serve different motion functions according to configuration. The control program and wiring record must agree on whether it is home, overtravel, probe, encoder, cam or general I/O.

Explanation 02

Diagnostic Layers

Encoder open-wire or loss diagnostics identify the feedback path, whereas communication status identifies the fiber link. Reading the correct layer prevents unnecessary replacement of a working sensor or FTB.

Explanation 03

Defined Failure State

Output safe states are configuration values applied after communication loss. They must be reviewed with the machine response because the block cannot determine the safe motion command on its own.

A safe-state setting must be verified as part of the motion configuration. It should not be inferred only from the terminal’s physical label.

05 · FAQ

Configuration Questions

How far can IC695FTB001-AA be installed from the PACMotion controller?

The full-duplex fiber path for IC695FTB001-AA can extend up to 100 m. Fiber routing and connector condition must still support the optical link.

What happens to IC695FTB001-AA outputs if fiber communication is lost?

IC695FTB001-AA moves its outputs to the configured safe state after communication loss. Verify those configured values before commissioning the motion system.

Does IC695FTB001-AA receive operating power through the fiber cable?

No. IC695FTB001-AA requires a local 19.2–28.8 VDC supply. The fiber carries communication and provides electrical separation, not field power.

Which motion signals can be assigned to IC695FTB001-AA terminals?

IC695FTB001-AA can handle configured overtravel, home, touch-probe, quadrature-encoder, cam and general-purpose I/O functions, plus the documented analog output paths.

How should an encoder fault be separated from a fiber-link fault on IC695FTB001-AA?

Use the IC695FTB001-AA status indications and diagnostics to distinguish open-wire or loss-of-encoder conditions from loss of controller communication. They refer to different parts of the signal chain.

What is the total 24 V output limit of IC695FTB001-AA?

The 24 V outputs of IC695FTB001-AA are limited to 0.5 A in total. Sum the connected loads rather than applying that current independently to every output.

06 · MOORE

Our Advantages

Moore Automation

https://www.mvme.cn/

Moore Automation uses complete-model identification, cross-checkable records and coordinated communication to keep industrial component requests clear. Available label, document and dispatch information stays linked to the same requested item.

Exact CodesFull model strings retained
Clear RecordsItem and request details connected
Document HandlingAvailable files coordinated by model
Process VisibilityUpdates referenced to the same enquiry
www.mvme.cn
07 · SELECT

Compatible Models

BeckhoffEL3356
Phoenix Contact2866776
Siemens6ES5377-0AA21
OmronR88D-KN20H-ECT
SICKUM18-212127111
ABB1SFA664003R1100
Mitsubishi ElectricQY50
Rockwell Automation440H-R03074
Honeywell51304542-100
General ElectricIS210BAPAH1A
BeckhoffKS3062
Phoenix Contact2866718
Siemens6ES5373-1AA41
OmronCIMR-F7Z41P5
SICKDFS60E-S1AA01024
ABBZHBM00-3P-M8
Mitsubishi ElectricQ65B
Rockwell Automation1769-0B16
HoneywellXFL821A
General ElectricDPI620G
BeckhoffBK9055
Phoenix Contact2863083
Siemens6ES5373-0AA41
OmronF150-C15E-3
SICKDME4000-119
ABB200-PSSG
Mitsubishi ElectricAD61
Rockwell Automation1492-CAB050RTN18
Honeywell621-0010
General Electric1C3569G3
BeckhoffC1120
Phoenix Contact2866213
Siemens4620079400.01
OmronNS5-SQ10B-V2
SICKDT50-N1113
ABBS200-0W8
Mitsubishi ElectricAD71
Rockwell Automation440E-A13080
Honeywell82408667-001
General ElectricDS200TCEAG2BTF
BeckhoffEJ1100-0000
Phoenix Contact2862246
Siemens3RH1911-1HA01
OmronNS5-SQ00-V2
SICKSRS50-HZA0-S39
ABB1SDA073697R1
Mitsubishi ElectricAD75M2
Rockwell Automation700-CF310KF
Honeywell621-6551R
General Electric369B1860G0033
BeckhoffKL3012
Phoenix Contact2320092
Siemens3ra2921-2aa00
OmronCJ1H-CPU65H
SICKDFS60B-S4PK10000
ABBS804S-B16
Mitsubishi ElectricA1S65B-S1
Rockwell Automation1771-P2
HoneywellJ-MHM10
General ElectricIS200TTURH1CED

Enquiry Desk

Moore Automation · Send the complete manufacturer, model and destination details through the contact channel that suits your request.

ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.