GE Fanuc · PACSystems RX3i
Four differential analog inputs and two single-ended outputs for voltage or current signals.
GE Fanuc IC694ALG442-ED is a PACSystems RX3i mixed analog module combining four differential inputs with two single-ended outputs. Each point can be configured for the supported voltage or current range, allowing one slot to receive field measurements and issue analog commands.
Input channels on IC694ALG442-ED use 12-bit conversion and refresh all four values within 8 ms. The two outputs use 16-bit conversion, update within 4 ms and can either hold their last value or move to the configured low-range state when system operation is interrupted.
An external isolated 24 VDC source supplies the field-side circuits of IC694ALG442-ED. Output ramp mode can limit the rate of command change, while input alarm and Enhanced 4–20 mA operation allow the controller to distinguish process limits and selected current-loop conditions from ordinary scaled data.
| Technical Item | IC694ALG442-ED |
|---|---|
| Brand | GE Fanuc |
| Product Type | PACSystems RX3i mixed analog I/O module |
| Brand Country | United States |
| Input Channels | 4 differential |
| Output Channels | 2 single-ended |
| Supported Ranges | 0–10 V, ±10 V, 0–20 mA and 4–20 mA |
| Enhanced Input Mode | Enhanced 4–20 mA |
| Input Resolution | 12 bit |
| Output Resolution | 16 bit |
| All-Input Update | 8 ms |
| All-Output Update | 4 ms |
| External Field Supply | Isolated 24 VDC |
| Backplane Current | 95 mA from 5 VDC |
| Field-Supply Current | 129 mA from 24 VDC |
| Output Default | Hold last state or low range; ramp mode supported |
The input and output sections of IC694ALG442-ED share one module but perform opposite conversions.
Each point is assigned a supported voltage or current range in hardware configuration.
Differential input pairs capture the field signal and convert it to 12-bit controller data.
The application uses the scaled input values to determine the required analog commands.
Sixteen-bit output circuits convert the controller commands into the selected field range.
The differential inputs translate field voltage or current into controller data, while the single-ended outputs translate controller data back into field signals. Their resolution and update behavior therefore differ.
The configured range determines how raw counts are scaled and how the terminal circuit is interpreted. A voltage/current mismatch cannot be repaired by changing only the displayed engineering units.
All four inputs are serviced within the input update interval and both outputs within the output interval. The controller scan adds another stage between measured inputs and calculated output commands.
A channel wired for current but configured for voltage will not be corrected by software scaling. Compare range selection with terminal wiring first.
The behavior of IC694ALG442-ED depends on configuration data and the independent field-power path.
The isolated 24 VDC source energizes the field-side analog circuitry.
Input values are compared with configured high and low boundaries.
Output ramp mode limits the rate at which a commanded value can change.
A stopped or interrupted system applies the selected hold or low-range behavior.
Backplane communication can remain valid when the isolated 24 V field source is absent. That condition affects analog circuitry without necessarily making the module disappear from hardware configuration.
Ramp mode limits how fast the output command changes toward its target. It shapes a normal transition and is distinct from the hold or low-range state used after an interruption.
Configured input alarms compare process values with thresholds. Enhanced 4–20 mA operation adds current-loop interpretation, so alarm state, range fault and field-power loss must be diagnosed separately.
A valid backplane connection does not prove that the external field supply is present. Check the 24 V path when all channels appear inactive.
Yes. IC694ALG442-ED configures its analog points by supported range, so the input and output sections can use different signal types when the hardware configuration and terminal wiring match.
IC694ALG442-ED requires an external isolated 24 VDC field supply in addition to backplane power. Verify that source before changing channel scaling.
IC694ALG442-ED updates all four inputs within 8 ms and both outputs within 4 ms. Application scan and communication timing remain additional parts of the complete response.
IC694ALG442-ED can hold the last output or move to the configured low-range value. Ramp settings govern commanded transitions during normal configured operation.
Enhanced 4–20 mA operation on IC694ALG442-ED is used for the supported current-input behavior and diagnostics. Configure it only on a channel wired as the corresponding current loop.
No suffix-specific terminal change is assumed for IC694ALG442-ED without an exact revision notice. Preserve ED in the record and use the verified module wiring and configuration for the installed unit.
https://www.mvme.cn/
Moore Automation processes enquiries across widely used control, motion and monitoring families, including GE Fanuc PACSystems and VersaMax, ABB AC500 and AC800M, Siemens SIMATIC and SINAMICS, and Yokogawa CENTUM products.
Moore Automation · Send the complete manufacturer, model and destination details through the contact channel that suits your request.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found