Product Name GE Fanuc IC693CPU374-HX CPU374 PLUS Controller
Item NO. 2945436
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-11-26

GE Fanuc IC693CPU374-HX CPU374 PLUS Controller

GE Fanuc · Series 90-30

GE Fanuc IC693CPU374-HX CPU374 PLUS Controller

A 133 MHz Series 90-30 CPU with configurable memory and two switched Ethernet ports under one IP address.

01 · ID

Product Facts

GE Fanuc IC693CPU374-HX identifies a CPU374 PLUS controller in the Series 90-30 family. The 133 MHz processor executes the user program, manages the local baseplate and connected expansion baseplates, and coordinates Ethernet exchanges through the controller’s integrated two-port interface.

Program, register and application data share the 240 KB configurable memory of IC693CPU374-HX. Battery-backed RAM supports the active controller record, while flash memory provides a nonvolatile storage path; the selected storage and startup settings determine which record becomes active after a power cycle.

The two RJ45 connectors on IC693CPU374-HX belong to an internal Ethernet switch and use one controller IP address. They can extend a local Ethernet path without representing two independent network interfaces, so both ports share the controller’s protocol and traffic resources.

02 · DATA

Performance Data

Technical Item IC693CPU374-HX
Brand GE Fanuc
Product Type Series 90-30 CPU374 PLUS controller
Brand Country United States
Processor 133 MHz AMD SC520, 586 class
Configurable Memory 240 KB
Program Storage Battery-backed RAM and flash
Ethernet Ports Two 10/100Base-T RJ45 ports
Ethernet Topology Internal switch, one IP address
Supported Ethernet Services SRTP, Ethernet Global Data and Modbus TCP
Expansion Capacity Up to 8 baseplates total
Power Requirement High-capacity Series 90-30 power supply
Backplane Load 7.4 W from 5 VDC
Floating Point Hardware floating-point support
Local Indication CPU and Ethernet status LEDs
03 · CORE

CPU374 Scan, Memory and Ethernet Path

The IC693CPU374-HX scan links stored logic, I/O data and Ethernet requests through distinct controller resources.

Stage 01

Acquire

The CPU refreshes the configured I/O state from the local and expansion baseplates.

Stage 02

Execute

The processor evaluates the program against the current register and I/O data.

Stage 03

Commit

Calculated output states are written back to the assigned modules.

Stage 04

Exchange

SRTP, EGD or Modbus TCP traffic accesses the controller through the switched Ethernet interface.

Explanation 01

Scan Order

Input refresh gives the application a stable I/O record for the current scan. Logic execution changes the output image, and the later output service transfers that result to the installed modules.

Explanation 02

Shared Controller Resources

Program execution, I/O service and Ethernet requests all use the CPU platform. A link that is electrically healthy can still respond slowly when the controller is busy with scan or communication work.

Explanation 03

Retention Choice

Battery-backed RAM holds the working record, while flash supplies a nonvolatile record under the selected startup setting. The two copies must be managed deliberately rather than assumed identical.

Network activity and program execution use the same controller platform. A communication load should therefore be assessed with the scan and memory allocation rather than judged only from link LEDs.

04 · CORE

Two-Port Switch and Firmware Record

The paired connectors on IC693CPU374-HX simplify cabling, but they remain ports of one embedded switch.

Stage 01

Single Identity

Both RJ45 connectors use the same controller IP address and Ethernet configuration.

Stage 02

Forwarding

Frames can pass between the two ports through the internal switch.

Stage 03

Controller Traffic

Packets addressed to the CPU are processed by the supported Ethernet services.

Stage 04

Revision Check

The HX suffix should remain part of the complete supply record when comparing firmware and replacement history.

Explanation 01

One Network Node

The two RJ45 sockets are switch ports behind one Ethernet identity. They extend the same LAN segment and cannot be configured as two isolated controller networks.

Explanation 02

Traffic Forwarding

Frames not addressed to the CPU can pass through the internal switch, while controller traffic is delivered to the enabled SRTP, EGD or Modbus TCP service. Cabling topology therefore affects both forwarding and controller access.

Explanation 03

Revision Discipline

The HX suffix belongs with the hardware record even when base CPU374 PLUS functions are unchanged. Firmware or replacement decisions require the complete label because nearby suffixes must not be treated as proof for HX.

Do not configure the two connectors as separate controller interfaces. A duplicate-IP investigation must treat IC693CPU374-HX as one Ethernet device.

05 · FAQ

Application Questions

Do the two Ethernet ports on IC693CPU374-HX need separate IP addresses?

No. IC693CPU374-HX uses an internal two-port switch behind one controller Ethernet identity, so both RJ45 connectors operate under the same IP configuration.

What should be retained before replacing an IC693CPU374-HX?

Retain the IC693CPU374-HX program, register allocation, hardware configuration, Ethernet settings and the selected RAM or flash startup behavior. The hardware alone does not recreate the active controller record.

Can IC693CPU374-HX be installed with a standard-capacity Series 90-30 power supply?

IC693CPU374-HX requires a high-capacity Series 90-30 power supply. Confirm the baseplate supply and total 5 V load before transferring the CPU.

Why can an IC693CPU374-HX Ethernet link be active while controller messaging still fails?

A link LED on IC693CPU374-HX only confirms the physical Ethernet connection. Check the shared IP settings, subnet, selected service and controller configuration when SRTP, EGD or Modbus TCP data does not pass.

How many baseplates can IC693CPU374-HX coordinate?

An IC693CPU374-HX system can include up to eight baseplates in total. The actual arrangement must still follow Series 90-30 expansion and power rules.

What does the HX suffix change in the way IC693CPU374-HX should be documented?

The complete IC693CPU374-HX suffix should be kept in the asset and spare record. Base CPU374 PLUS functions can be verified from the product documentation, while any suffix-specific firmware history must be checked against the exact unit label rather than inferred.

06 · MOORE

Shipping Services

Moore Automation

https://www.mvme.cn/

Moore Automation coordinates packing and dispatch information after the item and destination record are confirmed. The shipping record can include the selected carrier, package reference and tracking detail when those details become available.

Packing RecordItem and package details kept together
Carrier DetailSelected service recorded for the shipment
Dispatch NoticeRelease information shared through the agreed channel
Tracking UpdateReference passed on when issued by the carrier
www.mvme.cn
07 · SELECT

More Products

OmronE3S-LS20XE4
SICKDT500-A311
ABBK80E
Mitsubishi ElectricQ03UDCPU
Rockwell Automation1734-IE2V
HoneywellIO-16
General ElectricCL06A311M7
BeckhoffKS9185
Phoenix ContactUKH95
Siemens6ES7122-1BB00-0AA0
OmronA16S-3N2LS
SICKDT500-A411
ABB2TLA020070R2200
Mitsubishi ElectricFR-A840-00170-2-60
Rockwell Automation160BA03NSF1
Honeywell4DP7APCFA403
General ElectricIC200ALG322-G
BeckhoffKL1418
Phoenix ContactHC-M-05L-TPT-M
SiemensPT78703
OmronA22NZ-S-P1A
SICKCLV615-D2410
ABBR1551
Mitsubishi ElectricA68RD4
Rockwell Automation160-BA01NSF1P1
HoneywellDC2500-CE-3A0R-100-00000-E0-0
General ElectricIC200ETM001-A
BeckhoffKL9185
Phoenix ContactPT4-HESI
Siemens3NA1015
OmronE3Z-D87
SICKDL100-21AA2101
ABBOT80F3
Mitsubishi ElectricGT1050-QBBD
Rockwell Automation2711P-RN15S
Honeywell09437701D
General ElectricIC697CPM925-AB
BeckhoffKL2408
Phoenix Contact2726269
Siemens3RV1011-1AA10
OmronE2EG-X1R5B1
SICKDL100-22AA2102
ABB204-007-000-102
Mitsubishi ElectricHG-KN23JK
Rockwell Automation1734-TOPS
Honeywell09437702A
General ElectricIC200ALG620-GD
BeckhoffKL9400
Phoenix Contact8-2MBD
Siemens3RV1011-1EA10
OmronFH-5050
SICKDL100-21AA2112
ABB1420-200
Mitsubishi ElectricMR-JE-300A
Rockwell Automation100S-E190E
Honeywell09439300D
General ElectricIC640WMI310A
BeckhoffZS2000-2610
Phoenix Contact2726201
Siemens5SY4116-7

Sales Support

Moore Automation · Send the complete manufacturer, model and destination details through the contact channel that suits your request.

ManagerLeonia

No related record found