Acquire
The CPU refreshes the configured I/O state from the local and expansion baseplates.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | GE Fanuc IC693CPU374-HX CPU374 PLUS Controller |
| Item NO. | 2945436 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | GE |
| Brand | GE |
| Creation Time | 2026-11-26 |
GE Fanuc · Series 90-30
A 133 MHz Series 90-30 CPU with configurable memory and two switched Ethernet ports under one IP address.
GE Fanuc IC693CPU374-HX identifies a CPU374 PLUS controller in the Series 90-30 family. The 133 MHz processor executes the user program, manages the local baseplate and connected expansion baseplates, and coordinates Ethernet exchanges through the controller’s integrated two-port interface.
Program, register and application data share the 240 KB configurable memory of IC693CPU374-HX. Battery-backed RAM supports the active controller record, while flash memory provides a nonvolatile storage path; the selected storage and startup settings determine which record becomes active after a power cycle.
The two RJ45 connectors on IC693CPU374-HX belong to an internal Ethernet switch and use one controller IP address. They can extend a local Ethernet path without representing two independent network interfaces, so both ports share the controller’s protocol and traffic resources.
| Technical Item | IC693CPU374-HX |
|---|---|
| Brand | GE Fanuc |
| Product Type | Series 90-30 CPU374 PLUS controller |
| Brand Country | United States |
| Processor | 133 MHz AMD SC520, 586 class |
| Configurable Memory | 240 KB |
| Program Storage | Battery-backed RAM and flash |
| Ethernet Ports | Two 10/100Base-T RJ45 ports |
| Ethernet Topology | Internal switch, one IP address |
| Supported Ethernet Services | SRTP, Ethernet Global Data and Modbus TCP |
| Expansion Capacity | Up to 8 baseplates total |
| Power Requirement | High-capacity Series 90-30 power supply |
| Backplane Load | 7.4 W from 5 VDC |
| Floating Point | Hardware floating-point support |
| Local Indication | CPU and Ethernet status LEDs |
The IC693CPU374-HX scan links stored logic, I/O data and Ethernet requests through distinct controller resources.
The CPU refreshes the configured I/O state from the local and expansion baseplates.
The processor evaluates the program against the current register and I/O data.
Calculated output states are written back to the assigned modules.
SRTP, EGD or Modbus TCP traffic accesses the controller through the switched Ethernet interface.
Input refresh gives the application a stable I/O record for the current scan. Logic execution changes the output image, and the later output service transfers that result to the installed modules.
Program execution, I/O service and Ethernet requests all use the CPU platform. A link that is electrically healthy can still respond slowly when the controller is busy with scan or communication work.
Battery-backed RAM holds the working record, while flash supplies a nonvolatile record under the selected startup setting. The two copies must be managed deliberately rather than assumed identical.
Network activity and program execution use the same controller platform. A communication load should therefore be assessed with the scan and memory allocation rather than judged only from link LEDs.
The paired connectors on IC693CPU374-HX simplify cabling, but they remain ports of one embedded switch.
Both RJ45 connectors use the same controller IP address and Ethernet configuration.
Frames can pass between the two ports through the internal switch.
Packets addressed to the CPU are processed by the supported Ethernet services.
The HX suffix should remain part of the complete supply record when comparing firmware and replacement history.
The two RJ45 sockets are switch ports behind one Ethernet identity. They extend the same LAN segment and cannot be configured as two isolated controller networks.
Frames not addressed to the CPU can pass through the internal switch, while controller traffic is delivered to the enabled SRTP, EGD or Modbus TCP service. Cabling topology therefore affects both forwarding and controller access.
The HX suffix belongs with the hardware record even when base CPU374 PLUS functions are unchanged. Firmware or replacement decisions require the complete label because nearby suffixes must not be treated as proof for HX.
Do not configure the two connectors as separate controller interfaces. A duplicate-IP investigation must treat IC693CPU374-HX as one Ethernet device.
No. IC693CPU374-HX uses an internal two-port switch behind one controller Ethernet identity, so both RJ45 connectors operate under the same IP configuration.
Retain the IC693CPU374-HX program, register allocation, hardware configuration, Ethernet settings and the selected RAM or flash startup behavior. The hardware alone does not recreate the active controller record.
IC693CPU374-HX requires a high-capacity Series 90-30 power supply. Confirm the baseplate supply and total 5 V load before transferring the CPU.
A link LED on IC693CPU374-HX only confirms the physical Ethernet connection. Check the shared IP settings, subnet, selected service and controller configuration when SRTP, EGD or Modbus TCP data does not pass.
An IC693CPU374-HX system can include up to eight baseplates in total. The actual arrangement must still follow Series 90-30 expansion and power rules.
The complete IC693CPU374-HX suffix should be kept in the asset and spare record. Base CPU374 PLUS functions can be verified from the product documentation, while any suffix-specific firmware history must be checked against the exact unit label rather than inferred.
https://www.mvme.cn/
Moore Automation coordinates packing and dispatch information after the item and destination record are confirmed. The shipping record can include the selected carrier, package reference and tracking detail when those details become available.
Moore Automation · Send the complete manufacturer, model and destination details through the contact channel that suits your request.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found