Locate
Identify the physically unused slot in the applicable rack layout.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | GE Fanuc IC694ACC310A Blank-Slot Filler Module |
| Item NO. | 2945447 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | GE |
| Brand | GE |
| Creation Time | 2026-11-26 |
GE Fanuc · PACSystems RX3i
A passive mechanical filler that closes an unused IC694 or compatible RX3i rack position without entering the I/O configuration.
GE Fanuc IC694ACC310A is a filler module for an unused slot in the applicable IC694 or PACSystems RX3i rack arrangement. Its responsibility is mechanical: it occupies the open position and presents a finished front surface where no active controller or I/O module is installed.
Because IC694ACC310A contains no input, output, communication or power-conversion circuit, it does not exchange backplane data and does not require a hardware-configuration entry. The filler should not be counted as an active module when calculating I/O capacity or backplane current.
The position of IC694ACC310A remains part of the physical rack layout even though it is absent from the controller configuration. When an active module is later assigned to that slot, the filler is removed and the new module’s compatibility, power and configuration requirements are evaluated independently.
| Technical Item | IC694ACC310A |
|---|---|
| Brand | GE Fanuc |
| Product Type | Blank-slot filler module |
| Brand Country | United States |
| Catalog Family | IC694 accessories |
| Primary Function | Covers an unused rack position |
| Electrical Inputs | None |
| Electrical Outputs | None |
| Communication Interfaces | None |
| Backplane Data Exchange | None |
| Backplane Current | No active electrical load |
| Hardware Configuration | Not required |
| I/O Addressing | Not assigned |
| Installation Role | Passive mechanical slot occupancy |
The role of IC694ACC310A begins and ends at the unused rack position; it does not emulate an I/O module.
Identify the physically unused slot in the applicable rack layout.
Position the filler with the same front opening used by an active IC694-format module.
Seat the filler so the rack front remains organized and the open position is visibly identified.
Keep the filler in the mechanical layout while leaving it out of the controller I/O configuration.
The filler occupies the front opening without a powered backplane circuit. Its function is physical organization, so it has no status LEDs, terminal block or field wiring.
Using a filler makes an unused position clearly different from a missing active module. That visual distinction helps compare the actual rack with drawings and maintenance records.
The filler should not be assigned an environmental sealing claim that is not stated for the complete enclosure. It closes the rack position but does not independently certify the cabinet.
IC694ACC310A does not provide an environmental sealing rating by itself. Treat it as a rack filler, not as an enclosure-certification component.
The physical presence of IC694ACC310A must not create a false logical module record.
The filler occupies space in the rack and prevents another module from using that position.
It has no backplane electronic identity for the CPU to discover.
No input, output or communication address is allocated to the filler.
Replacing it with active hardware requires a new compatibility, power and configuration review.
The CPU cannot discover or address the filler because it does not communicate on the backplane. Any software module shown at that position comes from configuration, not from IC694ACC310A.
The filler counts as an occupied physical position but not as an I/O module, power load or addressed device. Rack drawings should show it without allocating controller data.
Installing active hardware in the position changes more than the front appearance. The replacement needs a compatible slot, available power, terminal plan, addressing and a downloaded hardware configuration.
If configuration software reports a module in the filler position, the hardware configuration and actual rack layout do not agree; IC694ACC310A itself cannot generate that record.
No. IC694ACC310A is a passive blank-slot filler with no backplane identity, I/O data or configuration record.
IC694ACC310A has no active electrical circuit and no backplane current demand. It occupies physical space but not the electrical load budget.
No. IC694ACC310A only fills an unused position and cannot perform input, output or communication functions. Update the control plan before leaving an active module position empty.
IC694ACC310A cannot identify itself to the CPU. If software shows a module in that slot, the downloaded hardware configuration or the recorded rack position does not match the physical layout.
Before removing IC694ACC310A, check rack compatibility, slot rules, power demand, terminal requirements, I/O addressing and the controller hardware configuration for the new module.
No. IC694ACC310A remains a blank-slot filler. Preserve the complete suffix for identification, but do not infer circuitry or I/O capability from the revision letter.
https://www.mvme.cn/
Moore Automation keeps industrial component requests organized around exact identification and traceable communication. Complete model records, available supporting files and process updates are reviewed without adding unsupported compatibility promises.
Moore Automation · Send the complete manufacturer, model and destination details through the contact channel that suits your request.