Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>GE>GE Fanuc IC200ALG322G VersaMax Analog Output Module
GE Fanuc IC200ALG322G VersaMax Analog Output Module

GE Fanuc IC200ALG322G VersaMax Analog Output Module Item NO.: 2945439

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name GE Fanuc IC200ALG322G VersaMax Analog Output Module
Item NO. 2945439
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-11-26

GE Fanuc IC200ALG322G VersaMax Analog Output Module

GE Fanuc · VersaMax

GE Fanuc IC200ALG322G VersaMax Analog Output Module

Four single-ended bipolar voltage outputs with a selectable power-up default for the field channels.

01 · ID

Hardware Details

GE Fanuc IC200ALG322G is a four-channel VersaMax analog voltage output module. It receives four commanded values from the I/O bus and converts each value into a single-ended field voltage over the ±10.24 V range.

The output converter of IC200ALG322G uses 12-bit resolution, producing 5 mV increments and updating all channels within 0.3 ms. The field side requires an external 18–30 VDC supply, while the backplane provides logic power and the data path to the controller.

A module jumper determines whether IC200ALG322G holds the last commanded output or drives the channels to zero when the I/O connection is lost. Field power and OK indicators distinguish missing output power from a module or communication condition before individual channel wiring is examined.

02 · DATA

System Specifications

Technical Item IC200ALG322G
Brand GE Fanuc
Product Type VersaMax four-channel analog voltage output module
Brand Country United States
Output Channels 4, single-ended
Output Range −10.24 to +10.24 VDC
Resolution 12 bit; 5 mV per count
Maximum Update Time 0.3 ms for all channels
External Supply 18–30 VDC
Backplane Current 50 mA maximum from 5 VDC
Minimum Resistive Load 5,000 ohms
Maximum Load Capacitance 1.0 µF
Crosstalk 70 dB
Loss-of-Communication Default Hold last state or zero, jumper selected
Isolation 250 VAC continuous field-to-logic; no channel-to-channel isolation
03 · CORE

Bipolar Output Conversion

Each command for IC200ALG322G passes through a shared module data path and a dedicated channel output circuit.

Stage 01

Command

The controller writes a signed output value into the channel’s assigned I/O data.

Stage 02

Scale

The module relates that value to the bipolar ±10.24 V engineering span.

Stage 03

Convert

A 12-bit converter resolves the command into 5 mV output increments.

Stage 04

Drive

The channel circuit applies the voltage to the field load from the external DC supply.

Explanation 01

Signed Command Path

Negative, zero and positive controller values occupy one bipolar data range. The converter maps that signed value around zero volts instead of treating the channel as a unipolar 0–10 V output.

Explanation 02

Resolution Meaning

A 5 mV increment is the smallest commanded step of the 12-bit conversion. It does not guarantee the connected load will settle to that value when supply, wiring or load impedance is outside the module boundary.

Explanation 03

Update Relationship

All four channels are refreshed within the documented module update period. Application scan and network timing are separate, so total command response includes more than the converter time alone.

A correct controller value cannot create the expected field voltage when the external 18–30 VDC source is absent. Compare the field-power LED with the commanded data before changing scaling.

04 · CORE

Carrier Terminals, Shields and Default State

The IC200ALG322G output return and cable arrangement determine how the converted signal reaches each load.

Stage 01

Pair

Run each voltage output with its assigned return to the receiving device.

Stage 02

Shield

Terminate cable shields according to the carrier and cabinet grounding plan without using them as signal returns.

Stage 03

Load

Keep the receiving impedance above the specified minimum and capacitance within the output limit.

Stage 04

Default

Set the hold-or-zero jumper to match the required state after I/O communication is lost.

Explanation 01

Return Conductors

Each load must be measured across its output and assigned return. Using a cabinet reference or another channel return can create a misleading voltage reading because the channels share a non-isolated module environment.

Explanation 02

Shield Function

A cable shield controls coupled noise but is not the signal return. Its cabinet termination must follow the installation grounding plan so shield current does not flow through the analog measurement path.

Explanation 03

Communication Loss

The jumper applies one module-level choice: retain the last commanded values or drive outputs to zero. The selected behavior should be recorded with the process requirement before commissioning.

The four outputs are not isolated from one another. Field wiring must not assume independent galvanic boundaries between channels.

05 · FAQ

Configuration Questions

Why does IC200ALG322G show an OK indication but produce no field voltage?

IC200ALG322G can have backplane logic power while the external 18–30 VDC field supply is missing. Check the field-power indication and measure the supply at the carrier before changing the controller value.

How is the post-communication output behavior selected on IC200ALG322G?

A hardware jumper on IC200ALG322G selects either hold-last-state or zero output when the I/O connection is lost. Record the jumper position before moving the module.

Can the four IC200ALG322G channels be treated as isolated outputs?

No. IC200ALG322G provides field-to-logic isolation but no channel-to-channel isolation. The returns and connected equipment must be planned with that shared electrical relationship in mind.

What load should be connected to an IC200ALG322G voltage output?

The receiving load on IC200ALG322G should be at least 5,000 ohms and no more than 1.0 µF capacitance. A heavier or highly capacitive load can prevent the command from settling correctly.

How should an IC200ALG322G command be converted to expected voltage?

IC200ALG322G spans −10.24 to +10.24 V with 5 mV resolution. Apply the configured signed scaling and compare the resulting expected voltage with a measurement across the channel output and return.

Does revision G make IC200ALG322G a different four-channel range?

The verified base function of IC200ALG322G remains the four-channel ±10.24 V output design. Keep the G revision in the supply record, but do not infer a different range without an exact revision notice.

06 · MOORE

Customer Support

Moore Automation

https://www.mvme.cn/

Moore Automation keeps product questions tied to one clear enquiry record. Manufacturer, complete model, quantity and destination are reviewed together so later document or label checks refer to the same requested item.

Enquiry RecordCore request details captured together
Model ReviewPrefix, number and suffix compared as one code
Document CheckAvailable product information linked to the request
CommunicationQuestions and updates kept in one thread
www.mvme.cn
07 · SELECT

Compatible Models

SICKDL100-21AA2110
ABBNDCU-11CK
Mitsubishi ElectricA3ACPUP21
Rockwell Automation100S-C09EJ14BC
Honeywell09439200D
General ElectricIC300DIQ616B
BeckhoffKL9160
Phoenix Contact2860015
Siemens5SY4104-7
OmronNX502-1300
SICKDL100-21AA2102
ABBMO325-A12
Mitsubishi ElectricFR-Z024-S2.2K
Rockwell Automation100S-E190E-A
Honeywell09434410E
General ElectricDPI812
BeckhoffKL1124
Phoenix Contact2740106
Siemens6ES7132-4BD00-0AA0
OmronCJ2H-CPU67
SICKTIM571-2050101
ABBMO325-A26
Mitsubishi ElectricA2ASCPU-S60
Rockwell Automation100-D115ZS22L
HoneywellJ-MBU01
General ElectricIC693ACC307A
BeckhoffEL9184
Phoenix ContactCM90-PS-120AC
Siemens1NET8120668-01
OmronNA5-9W001S-V1
SICKCLV632-3000
ABB1SDA038324R1
Mitsubishi ElectricE900
Rockwell Automation1794-IB16XOB16P
HoneywellTVEZ-6-0-0-000-0-000000-00
General Electric44C740004
BeckhoffES2008
Phoenix Contact2800837
Siemens6ES7972-0BA50-0XA0
OmronNS8-TV01-V2
SICKKT5W-2P1116
ABBT3S-250
Mitsubishi ElectricGT1030-HBL
Rockwell Automation1787-PLUG10R
Honeywell621-0020
General ElectricIC200MDL730-J
BeckhoffEL9187
Phoenix Contact2862974
Siemens3RV1915-5DB
OmronNX102-1020
SICKDT20-P244B
ABB1SAR501020R0003
Mitsubishi ElectricQ62DAN
Rockwell Automation1492IFM40F
Honeywell942-A4M-2D-K300E
General ElectricIC200UEX011-A
BeckhoffKM1002
Phoenix Contact2863931
Siemens6ES7390-7BA00-0AA0
OmronCS1H-CPU66H

Enquiry Desk

Moore Automation · Send the complete manufacturer, model and destination details through the contact channel that suits your request.

ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.