Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>GE>GE IC200BEM003-CA VersaMax PROFIBUS Master Module
GE IC200BEM003-CA VersaMax PROFIBUS Master Module

GE IC200BEM003-CA VersaMax PROFIBUS Master Module Item NO.: 2940717

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name GE IC200BEM003-CA VersaMax PROFIBUS Master Module
Item NO. 2940717
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-11-18

GE IC200BEM003-CA VersaMax PROFIBUS Master Module
VersaMaxPROFIBUS master
PROFIBUS DP interface

GE IC200BEM003-CA VersaMax PROFIBUS Master Module

A VersaMax PROFIBUS-DP V1 master for CPU- and PNS-based I/O stations.

Product Information

GE IC200BEM003-CA is a VersaMax PROFIBUS-DP V1 master module that installs on the IC200CHS006 communications carrier. It provides the controller-side master interface for cyclic input, output and diagnostic exchange between a VersaMax host and the PROFIBUS devices connected to the fieldbus segment.

GE IC200BEM003-CA operates with a compatible VersaMax CPU005, CPUE05 or supported PROFINET Scanner. Its PROFIBUS station address is configured in software, network operation covers data rates from 9.6 kbit/s to 12 Mbit/s, and one master can coordinate as many as 125 addressed slave stations.

Each slave connected to GE IC200BEM003-CA is defined by its GSD identity, installed module order and allocated I/O length. The module handles cyclic data together with Sync, Freeze and DP-V1 Read, Write and Alarm services, while its status indicators and diagnostic arrays separate host communication, bus activity and individual slave conditions.

GE IC200BEM003-CA VersaMax PROFIBUS master operating requirements
Controller, software and power-supply requirements for GE IC200BEM003-CA in a VersaMax PROFINET station.

Technical Data

Specification IC200BEM003-CA
Brand GE
Product name VersaMax PROFIBUS master module
Installation VersaMax communications carrier IC200CHS006
Network role PROFIBUS-DP V1 master
Power consumption 450 mA at 5 V DC
Station address 0 to 125, software configurable
Default station address 0
Maximum slaves 125
Network data rate 9.6 kbit/s to 12 Mbit/s
CPU data capacity Up to 3584 bytes input and 3584 bytes output
PNS data capacity Up to 1440 bytes input and 1440 bytes output
Per-slave data Up to 244 bytes input and 244 bytes output
Device definition Slave devices created from GSD files
Services Sync, Freeze and DP-V1 Read/Write/Alarm
Isolation 1500 V AC network-to-backplane minimum

System Integration

The module links a VersaMax host, one PROFIBUS segment and the configured slave database into a cyclic I/O system.

HOST PATH

Exchange data through the carrier

IC200BEM003-CA transfers cyclic input, output and diagnostic data through the communications carrier to the VersaMax CPU or supported PROFINET Scanner. The host determines the available memory resources.

SLAVE MODEL

Build each station from its GSD record

A slave entry combines station address, GSD identity, installed module order and byte mapping. The master scans that stored structure and exposes mismatches as network diagnostics.

BUS CYCLE

Coordinate rate, distance and device count

PROFIBUS timing is shared by every station on the segment. Data rate, cable length, repeater boundaries and slave response times together determine the completed scan cycle.

Diagnostics and Protection

The diagnostic path distinguishes master state, segment health and individual slave configuration.

MASTER STATE

Read module and communication indications together

The front indicators distinguish module operation from active PROFIBUS exchange. A healthy host interface can therefore coexist with an offline fieldbus segment.

SEGMENT STATE

Use the first missing station as a boundary

When several consecutive slaves disappear, the first missing address often marks the cable, connector or powered-device boundary. The two physical ends remain the only terminated points.

SLAVE DETAIL

Interpret station-specific diagnostics

A single offline slave can report address, GSD identity, parameter or module-layout differences while the rest of the segment continues cyclic exchange.

Product Questions

Which host systems can operate GE IC200BEM003-CA?
GE IC200BEM003-CA can operate with a compatible VersaMax CPU005 or CPUE05 and with a supported VersaMax PROFINET Scanner in an RX3i PROFINET station.
What files are needed to rebuild an GE IC200BEM003-CA network?
For GE IC200BEM003-CA, retain the controller project, PROFIBUS address list, GSD files, slave-module layout and configured baud rate.
What should be checked first when GE IC200BEM003-CA loses several slaves?
When GE IC200BEM003-CA loses several slaves, inspect segment power, connectors, shield, both terminations and the first missing station before replacing the master.
Where is GE IC200BEM003-CA installed?
GE IC200BEM003-CA installs on the VersaMax IC200CHS006 communications carrier and exchanges data with the CPU or PNS through that carrier.
Why can one GE IC200BEM003-CA slave remain offline after a project download?
For GE IC200BEM003-CA, check the slave address, exact GSD/device revision, configured module order and diagnostic bytes for that station.
Why can the COM indicator remain inactive on GE IC200BEM003-CA?
On GE IC200BEM003-CA, an inactive COM indication can result from an unconfigured master, stopped bus state, missing segment power, incorrect termination or no responding PROFIBUS slaves.

PROFIBUS Network Support

Moore Automation warehouse and service image for IC200BEM003-CA

Moore Automation

https://www.mvme.cn

Moore Automation coordinates PROFIBUS module enquiries with the surrounding carrier, cable, connector and slave-device requirements. The commercial record can keep the exact model, network accessories, destination and shipment details together for one complete request.

Master-module sourcingCarrier coordinationNetwork accessoriesShipment communication

Product Recommendations

ABBPM858K01 3BSE082895R1
Rockwell Automation1394C-SJT05-A
GEIC600CB504
Siemens6ES7193-4CA30-0AA0
ABBPM858K02 3BSE082896R1
Rockwell Automation1394C-SJT10-A
GEIC600CB507
Siemens6ES7193-4CB30-0AA0
ABBPM860AK01 3BSE066495R1
Rockwell Automation2094-BC01-M01-S
GEIC600CP620
Siemens6ES7193-4CD30-0AA0
ABBPM860K01 3BSE018100R1
Rockwell Automation2094-BC01-MP5-S
GEIC600CP630
Siemens6ES7193-4CE00-0AA0
ABBPM861AK01 3BSE018157R1
Rockwell Automation2094-BC02-M02-S
GEIC610ABM100
Siemens6ES7193-4CE10-0AA0
ABBPM861AK02 3BSE018160R1
Rockwell Automation2094-BC04-M03-S
GEIC610CBL105
Siemens6SL3210-5BE17-5UV0
ABBPM862K01 3BSE076940R1
Rockwell Automation2094-BC07-M05-S
GEIC610CCM100
ABBPM862K02 3BSE081636R1
Rockwell Automation2094-BM01-S
GEIC610CCM105
ABBPM863K01 3BSE088381R1
Rockwell Automation2094-BM02-S
GEIC610CCM110
ABBPM863K02 3BSE088382R1
Rockwell Automation2094-BM03-S
GEIC610CPU105
ABBPM864AK01 3BSE018161R1
Rockwell Automation2094-BMP5-M
GEIC610CPU106
ABBPM864AK02 3BSE018164R1
Rockwell Automation2094-BMP5-S
GEIC610IAL101
ABBPM865K01 3BSE031151R1
Rockwell Automation2098-DSD-030
GEIC610IAL115
Rockwell Automation2098-DSD-150
GEIC610MDL125
Rockwell Automation2098-DSD-HV220
GEIC610MDL158
Rockwell Automation2198-D032-ERS4
GEIC610MDL185
Rockwell Automation2198-D057-ERS3
GEIC610ODD100
Rockwell Automation2198-P070
GEIC610ODR101
Rockwell Automation2198-P208
GEIC610PRG105
Rockwell Automation2198-S086-ERS3
GEIC610PWR101
Rockwell Automation2198-S160-ERS3

Sales Enquiries

Manager / EmailLeoniasales@mvme.cn

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.