Short protected route
PR9268/200-000 uses 3 m armored cable where mechanical protection is part of the assembled sensor record.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Emerson PR9268/200-000 / PR9268/207-100 Vertical Electrodynamic Velocity Sensors |
| Item NO. | 2944908 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | EMERSON |
| Brand | EMERSON |
| Creation Time | 2026-11-25 |
Emerson PR9268/200-000 / PR9268/207-100 are PR9268 vertical electrodynamic velocity sensors for absolute bearing-vibration measurement. Both use the standard-temperature 20x construction and produce a velocity-proportional signal across the documented 4 to 1000 Hz operating range.
PR9268/200-000 combines the vertical sensor body with a 3 m armored cable and Harting connector. PR9268/207-100 keeps the same vertical measurement class but uses a 10 m non-armored cable with open wire ends, creating different cable-protection and termination boundaries.
For PR9268/200-000 / PR9268/207-100, vertical installation may deviate up to ±30° without sinking current and up to ±60° when the specified sinking current is applied. The sensor body, mounting surface and cable route work together to preserve the mechanical reference used by the moving-coil measurement system.
| Specification | PR9268/200-000 | PR9268/207-100 |
|---|---|---|
| Brand | Emerson | Emerson |
| Product Type | Electrodynamic velocity sensor | Electrodynamic velocity sensor |
| Brand Country | United States | United States |
| Measurement direction | Vertical | Vertical |
| Temperature class | Standard, up to 100 °C | Standard, up to 100 °C |
| Cable length | 3 m | 10 m |
| Cable protection | Armored | Non-armored |
| Termination | Harting connector | Open wire ends |
| Frequency range | 4 to 1000 Hz | 4 to 1000 Hz |
| Nominal sensitivity | 28.5 mV/mm/s | 28.5 mV/mm/s |
| Mounting deviation without sinking current | Up to ±30° | Up to ±30° |
| Mounting deviation with sinking current | Up to ±60° | Up to ±60° |
| Measuring principle | Electrodynamic moving coil | Electrodynamic moving coil |
| Signal type | Velocity-proportional voltage | Velocity-proportional voltage |
| Housing role | Mechanical reference and coil guidance | Mechanical reference and coil guidance |
Emerson PR9268/200-000 / PR9268/207-100 share the sensing principle but arrive with materially different field-cable boundaries.
PR9268/200-000 uses 3 m armored cable where mechanical protection is part of the assembled sensor record.
PR9268/207-100 uses 10 m non-armored cable, requiring the installation to provide route protection and bend control.
A Harting plug ends PR9268/200-000; open conductors end PR9268/207-100 and must land on the documented terminals.
Emerson PR9268/200-000 / PR9268/207-100 convert housing motion into a velocity signal through a suspended electrodynamic system.
The sensor base follows machine vibration while the internal inertial mass provides the relative-motion reference.
The vertical mechanism operates within ±30° without assistance and accepts a wider ±60° window with sinking current.
Mechanical movement is converted to a velocity-proportional electrical signal across the 4 to 1000 Hz band.
Inspect the mating Harting connector, locking hardware and cable entry on Emerson PR9268/200-000. A secure plug with damaged contacts or shield continuity can still create a vibration-dependent open circuit.
Use the documented conductor and shield assignment for Emerson PR9268/207-100, then verify continuity from the sensor cable end. Do not infer polarity from another cable assembly merely because the colors look similar.
No. Maintain the documented bend radius and strain relief on Emerson PR9268/200-000. The armor protects the route, but a tight bend at the gland can damage conductors or transmit mechanical force into the sensor.
The moving mass inside Emerson PR9268/200-000 / PR9268/207-100 is gravity-sensitive. Stay within ±30° without sinking current, or provide the specified sinking current for installation up to ±60°.
Follow the monitoring-system grounding arrangement for Emerson PR9268/207-100 and avoid multiple uncontrolled shield bonds. A deliberate single reference helps prevent ground-loop current from entering the velocity signal.
Compare the phase of Emerson PR9268/200-000 / PR9268/207-100 with a known machine reference and verify the documented conductor polarity. Reversed leads invert the signal even when the amplitude appears plausible.
Moore Automation treats lead time as a key part of industrial supply. Account managers communicate realistic timing, coordinate dispatch with the requested carrier where practical and provide tracking details so shipment progress remains visible from collection through delivery.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.