Emerson PR6424/011-110 / PR6424/000-031 16 mm Eddy Current Sensors
Two complete PR6424 sensor configurations with different cable and connector arrangements
Model Summary
Non-contact shaft displacement is the common function of Emerson PR6424/011-110 / PR6424/000-031. Both records belong to the 16 mm PR6424 family, with a nominal 4 V/mm sensitivity, approximately 2.7 mm center gap and a static range of plus or minus 2 mm for ferromagnetic targets.
Configuration PR6424/011-110 / PR6424/000-031 separates into two different mechanical assemblies. PR6424/011-110 uses an M18×1.5 case, armored cable, 50 mm sensor length, no adapter plug, a 5 m cable and LEMO end; PR6424/000-031 uses the same thread without armor, a 40 mm sensor length, an adapter plug, an 8 m cable and open end.
Turbomachinery duties supported by PR6424/011-110 / PR6424/000-031 include radial or axial dynamic displacement, position, eccentricity and speed/key measurement. The documented target is ferromagnetic 42CrMo4 steel with a minimum shaft diameter of 80 mm.
Technical Reference
| Technical Item | PR6424/011-110 | PR6424/000-031 |
|---|---|---|
| Brand | Emerson | Emerson |
| Product Type | 16 mm eddy-current sensor | 16 mm eddy-current sensor |
| Brand Country | United States | United States |
| Case Thread | M18×1.5 | M18×1.5 |
| Cable Armor | With armor | Without armor |
| Sensor Length Code | 50 mm | 40 mm |
| Adapter Plug | Without | With |
| Total Cable Length | 5 m | 8 m |
| Cable End | LEMO | Open |
| Sensitivity / Linearity | 4 V/mm; ≤ ±1.5% | 4 V/mm; ≤ ±1.5% |
| Nominal Center Gap | Approx. 2.7 mm | Approx. 2.7 mm |
| Static / Dynamic Range | ±2.0 mm / 0 to 1,000 µm | ±2.0 mm / 0 to 1,000 µm |
| Operating Temperature | -35 to +150 °C | -35 to +150 °C |
| Minimum Shaft Diameter | 80 mm | 80 mm |
Dual Configuration Identity
The two PR6424 records share measurement performance but not delivery geometry.
PR6424/011-110 / PR6424/000-031 must remain as two complete order strings. Thread, armor, sleeve length, adapter, cable length and termination are encoded independently, so the shared 16 mm sensing family does not make the assemblies interchangeable.
Armored 5 m path
PR6424/011-110 in PR6424/011-110 / PR6424/000-031 combines armor and LEMO termination without the intermediate adapter plug.
Standard 8 m path
PR6424/000-031 in PR6424/011-110 / PR6424/000-031 uses standard cable, an adapter plug and an open cable end.
Shaft Measurement Geometry
Both members of PR6424/011-110 / PR6424/000-031 operate around an approximate 2.7 mm nominal center gap.
The documented performance of PR6424/011-110 / PR6424/000-031 is referenced to ferromagnetic 42CrMo4 steel and a shaft at least 80 mm in diameter.
The 25 mm standard-cable and 35 mm armored-cable minimum bend radii distinguish the routing envelope of PR6424/011-110 / PR6424/000-031.
User Questions
What is the main physical difference inside PR6424/011-110 / PR6424/000-031?
PR6424/011-110 / PR6424/000-031 separates an armored 5 m LEMO assembly from a standard 8 m open-end assembly. Their adapter-plug and sleeve-length codes also differ, so the complete strings should not be collapsed into PR6424 alone.
Which bend radius applies to the armored member of PR6424/011-110 / PR6424/000-031?
The armored cable used by PR6424/011-110 within PR6424/011-110 / PR6424/000-031 has a documented minimum bend radius of 35 mm. The unarmored PR6424/000-031 path uses the 25 mm standard-cable minimum.
Can PR6424/011-110 / PR6424/000-031 measure the same shaft material without recalibration?
Both configurations in PR6424/011-110 / PR6424/000-031 use the PR6424 performance reference for ferromagnetic 42CrMo4 steel. A materially different target can change scale behavior and should not be assumed equivalent.
What nominal gap should be expected for PR6424/011-110 / PR6424/000-031?
The PR6424 family center gap used by PR6424/011-110 / PR6424/000-031 is approximately 2.7 mm. Final setup still follows the converter output and installed mechanical reference.
Why does the connector record matter for PR6424/011-110 / PR6424/000-031?
PR6424/011-110 ends in LEMO, while PR6424/000-031 has an open end in PR6424/011-110 / PR6424/000-031. That difference changes the downstream termination and cannot be inferred from cable length alone.
What shaft-size boundary applies to PR6424/011-110 / PR6424/000-031?
The specified minimum shaft diameter for PR6424/011-110 / PR6424/000-031 is 80 mm. Using a smaller target moves outside the stated geometric reference for the 16 mm sensor.
Quality Record Assurance
Moore Automation
https://www.mvme.cn/Moore Automation uses product-label review and documented records to keep both Emerson PR6424/011-110 / PR6424/000-031 configurations distinct. Connector, cable and suffix details remain visible during inspection, while traceable communication preserves the identity of each hard-to-find automation component.
Associated Products
| Control & Process | PLC & I/O | Monitoring & Network | Drives & Power |
|---|---|---|---|
| 01Yokogawa EB402 | 16Yokogawa ADV159 | 31GE IC600BF830 | 46ABB TB541-ETH |
| 02Yokogawa ADV561 | 17GE IC600CB536 | 32ABB TB511-ETH | 47Allen-Bradley 1756-IR6I |
| 03GE IC600CB526 | 18ABB TU531 | 33Allen-Bradley 1756-IF8 | 48Emerson KJ3002X1-BF1 |
| 04ABB TU515 | 19Allen-Bradley 1756-IB16D | 34Emerson KJ3002X1-BD1 | 49Honeywell CC-GAOX11 |
| 05Allen-Bradley 1756-IA16 | 20Emerson KJ3002X1-BB1 | 35Honeywell CC-TCF912 | 50Yokogawa AAP135 |
| 06Emerson KJ3001X1-BB1 | 21Honeywell CC-TCF902 | 36Yokogawa AAT145 | 51GE IC600BF843 |
| 07Honeywell CC-TCNT02 | 22Yokogawa AAT141 | 37Yokogawa ADV169 | 52ABB TB561-ETH |
| 08Yokogawa VI701 | 23Yokogawa ADV559 | 38GE IC600BF831 | 53Allen-Bradley 1756-IT6I |
| 09Yokogawa ADV859 | 24GE IC600CB537 | 39ABB TB521-ETH | 54Emerson KJ3002X1-BG2 |
| 10GE IC600CB527 | 25ABB TU532 | 40Allen-Bradley 1756-IF16 | 55Honeywell CC-GDIL11 |
| 11ABB TU516 | 26Allen-Bradley 1756-IB32 | 41Emerson KJ3002X1-BE1 | 56Yokogawa AAP149 |
| 12Allen-Bradley 1756-IB16 | 27Emerson KJ3002X1-BC1 | 42Honeywell CC-GAIX11 | 57GE IC600BF908 |
| 13Emerson KJ3002X1-BA1 | 28Honeywell CC-TCF911 | 43Yokogawa AAR145 | 58ABB PM851K01 |
| 14Honeywell CC-TCF901 | 29Yokogawa AAR181 | 44Yokogawa ADV569 | 59Allen-Bradley 1756-OA16 |
| 15Yokogawa VI702 | 30Yokogawa ADV869 | 45GE IC600BF832 | 60Emerson KJ3002X1-BH1 |









No related record found