Emerson KC3010X1-BK1 S-Series 16-Channel 4-20 mA HART Plus Card
High-density analog input with bussed field power and HART communication
Equipment Profile
Sixteen 4-20 mA process loops share one S-series analog-input position on Emerson KC3010X1-BK1. HART communication travels with the current measurement so supported transmitter variables and device status remain available through the same DeltaV input card.
Power reaches KC3010X1-BK1 through two defined paths: 12 VDC local-bus power for the card electronics and 24 VDC bussed field power for the loop side. Each field circuit is rated at 24 VDC and 30 mA per channel, keeping channel loading separate from the carrier electronics budget.
Mechanical assignment is fixed by the A6 terminal-block key on KC3010X1-BK1. The card is marked for industrial temperatures from -40 to +70 °C, G3 airborne contaminants and the documented Class I Division 2 / Zone 2 system arrangement.
Operating Data
| Technical Item | KC3010X1-BK1 |
|---|---|
| Brand | Emerson |
| Product Type | S-Series 4-20 mA HART Plus analog input card |
| Brand Country | United States |
| Input Channels | 16 |
| Input Signal | 4-20 mA |
| Digital Communication | HART |
| Local Bus Power | 12 VDC at 150 mA |
| Bussed Field Power | 24 VDC at 500 mA |
| Field Circuit | 24 VDC at 30 mA per channel |
| Terminal Block Key | A6 |
| Ambient Temperature | -40 to +70 °C |
| Relative Humidity | 5 to 95%, non-condensing |
| Shock and Vibration | 10 g half-sine for 11 ms; 1 mm p-p at 2-13.2 Hz; 0.7 g at 13.2-150 Hz |
| Airborne Contaminants | ISA-S71.04-1985 Class G3 |
Sixteen-Loop HART Signal Flow
Each loop carries its process current while HART data remains addressable by DeltaV.
On KC3010X1-BK1, sixteen 4-20 mA channels occupy one card while HART communication rides on the individual loop signal. The card therefore links conventional current measurement and supported device diagnostics without assigning a separate communication module.
Channel independence
The 30 mA field-circuit rating applies per channel on KC3010X1-BK1, so a loop condition is evaluated against its own wiring and transmitter load.
HART visibility
HART-capable field devices connected to KC3010X1-BK1 retain their digital communication path through the configured analog input.
Bussed Field-Power Boundaries
KC3010X1-BK1 draws 150 mA from the nominal 12 VDC local bus for its card electronics.
The 24 VDC bussed field-power allocation for KC3010X1-BK1 is 500 mA across the loop-side arrangement.
Field and system power are removed before KC3010X1-BK1 or its keyed termination is connected or removed.
Purchasing Questions
How many HART loops can KC3010X1-BK1 place on one card?
KC3010X1-BK1 provides sixteen 4-20 mA HART input channels. The configured channel count should be reconciled with the installed terminal assignment before loop checks begin.
Why is the A6 key important on KC3010X1-BK1?
A6 is the documented terminal-block key for KC3010X1-BK1. It is the mechanical safeguard that keeps the 16-channel HART input card paired with the intended S-series termination.
What should be checked when HART data is absent but KC3010X1-BK1 still reads current?
A valid 4-20 mA value on KC3010X1-BK1 proves only the analog path. Confirm the field device supports HART, the loop wiring and impedance are suitable, and HART is enabled in the DeltaV channel configuration.
How is the power budget for KC3010X1-BK1 divided?
KC3010X1-BK1 uses 12 VDC at 150 mA from the local bus and 24 VDC at 500 mA of bussed field power. Treating those as separate loads prevents the card electronics and transmitter loops from being combined into one incorrect total.
May KC3010X1-BK1 be removed with only field power isolated?
No; KC3010X1-BK1 also requires system power to be de-energized before insertion or removal. Isolating the loop supply alone does not satisfy the documented removal boundary.
What cabinet condition matters at the top of the KC3010X1-BK1 humidity range?
The 95% relative-humidity limit for KC3010X1-BK1 is explicitly non-condensing. Condensation inside the S-series enclosure is therefore not an acceptable operating condition.
Industrial Inventory Network
Moore Automation
https://www.mvme.cn/Moore Automation combines a broad industrial-automation inventory with product-record control for Emerson KC3010X1-BK1. PLC, DCS, I/O and process-control families are coordinated through an international supply network, with hard-to-find identities retained as complete model strings.
Selected Products
| Control & Process | PLC & I/O | Monitoring & Network | Drives & Power |
|---|---|---|---|
| 01Honeywell CC-PDIL01 | 16ABB DP865 | 31Yokogawa AAI143 | 46GE IC610CCM105 |
| 02ABB DP820 | 17Yokogawa AAB842 | 32GE IC610PRG105 | 47ABB AI523 |
| 03Yokogawa AAI841 | 18GE IC610ODD100 | 33ABB DO561 | 48Allen-Bradley 1756-L84E |
| 04GE IC200ALG331 | 19ABB DO524 | 34Allen-Bradley 1756-L82E | 49Emerson KJ2005X1-MQ1 |
| 05ABB DI561 | 20Allen-Bradley 1756-L75 | 35Emerson KJ2003X1-BK1 | 50Honeywell TC-PRR021 |
| 06Allen-Bradley 1756-L73 | 21Emerson KJ2002X1-BA1 | 36Honeywell CC-PDOB51 | 51Yokogawa AFV40S |
| 07Emerson VE3051C3 | 22Honeywell CC-PUIO01 | 37Yokogawa AFV30S | 52Yokogawa AAV544 |
| 08Honeywell CC-PFB401 | 23Yokogawa AFV10S | 38Yokogawa AAI543 | 53GE IC610CCM110 |
| 09ABB DP840 | 24Yokogawa AAV542 | 39GE IC610CCM100 | 54ABB AI531 |
| 10Yokogawa AAB841 | 25GE IC610CBL105 | 40ABB DO562 | 55Allen-Bradley 1756-L85E |
| 11GE IC610ODR101 | 26ABB DO525 | 41Allen-Bradley 1756-L83E | 56Emerson KJ2005X1-MQ2 |
| 12ABB DI562 | 27Allen-Bradley 1756-L81E | 42Emerson KJ2005X1-BA1 | 57Honeywell TC-CCR013 |
| 13Allen-Bradley 1756-L74 | 28Emerson KJ2003X1-BB1 | 43Honeywell TK-PRR021 | 58Yokogawa AFV40D |
| 14Emerson VE3051C4 | 29Honeywell CC-PDIL51 | 44Yokogawa AFV30D | 59Yokogawa AAI135 |
| 15Honeywell CC-PDOB01 | 30Yokogawa AFV10D | 45Yokogawa AAV144 | 60GE IC610ABM100 |







No related record found