Conductive target
The shaft or plain surface moves inside the measuring field. Its distance from the PR6423/012-140 tip changes the electromagnetic interaction without physical contact.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Emerson EPRO PR6423/012-140 8 mm Eddy Current Sensor |
| Item NO. | 2945315 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | EMERSON |
| Brand | EMERSON |
| Creation Time | 2026-11-25 |
Machinery health measurement component
Exact configuration: M10x1 thread, armored cable, 45 mm sensor length, 10 m cable and LEMO termination.
Emerson EPRO PR6423/012-140 is an 8 mm eddy current sensor in the PR6423 machinery-health measuring family. It forms the non-contact sensing end of a complete eddy-current measuring chain, converting the changing gap between its tip and a conductive shaft surface into the probe signal carried to a matched converter for displacement, vibration, position, eccentricity or speed measurement.
At the measuring point, PR6423/012-140 faces the target without mechanical contact. The sensor cable transfers the probe response to the converter, and the converter turns that response into the voltage used by the connected monitoring electronics. Accuracy therefore belongs to the complete sensor-converter chain and to its adjustment for the actual target material, not to the probe body alone.
The order code of PR6423/012-140 fixes an M10x1 threaded body, armored cable, 45 mm total sensor length, no adapter plug, a 10 m total cable and a LEMO cable end. The threaded body secures the probe in a stiff holder while the armored route protects the signal path; the cable still has to remain free from twist, strain and the moving parts of the machine.
| Attribute | PR6423/012-140 |
|---|---|
| Brand | Emerson EPRO |
| Product Type | 8 mm eddy current sensor |
| Brand Country | Germany |
| Series | PR6423 |
| Linear Measurement Range | 2 mm (80 mils) |
| Initial Air Gap | 0.5 mm (20 mils) |
| Incremental Scale Factor | 8 V/mm (203.2 mV/mil), ±5% at 0 to 45°C |
| Deviation from Best Fit Straight Line | ±0.025 mm (±1 mil) at 0 to 45°C |
| Minimum Shaft Diameter | 25 mm |
| Standard Target Material | 42CrMo4 / AISI SAE 4140 ferromagnetic steel |
| Protection Class | IP66, IEC 60529 |
| Case Thread | M10x1 |
| Armored Cable | Yes |
| Total Sensor Length | 45 mm |
| Adapter Plug | Without |
| Total Cable Length | 10 m |
| Cable End | LEMO male connector |
| Operating Temperature | Sensor with 1 m cable: -35 to +180°C; cable and connector: -35 to +150°C |
| Materials | PEEK tip; stainless-steel case; PTFE cable; nickel-plated brass connector |
The shaft or plain surface moves inside the measuring field. Its distance from the PR6423/012-140 tip changes the electromagnetic interaction without physical contact.
The 8 mm sensor head turns the changing gap into a corresponding probe response. Surface condition, target material and alignment all influence whether that response represents the real shaft motion.
The fixed 10 m armored cable carries the PR6423/012-140 response to its LEMO termination. The cable length is part of the configured measurement chain and is not an installation surplus to be shortened.
A compatible, target-adjusted converter changes the sensor response into the output voltage accepted by the monitoring electronics. Gap setting is checked through that converter output, so the probe and converter have to be commissioned together.
The output of PR6423/012-140 can change because the shaft moves, but it can also change when the holder, target track or cable route introduces an unwanted mechanical effect. These boundaries separate the intended gap signal from installation error.
Use a stiff, vibration-free M10x1 holder. During adjustment, keep at least two threads free toward the sensor head and secure the supplied nuts to a maximum fastening torque of 15 Nm.
Keep 45 degrees of free space around the head and limit axial tilt to less than 2 degrees. Nearby metal or excessive angle can reduce the usable upper range and increase linearity error.
The measuring track must be free from scratches, corrosion and metallurgical irregularities. Those conditions can create output-voltage changes that look like position or vibration even when the shaft gap has not changed.
Adjust the distance with the complete PR6423/012-140 measuring chain connected. The converter output supplies the usable reference for positioning the probe; the sensor body alone does not provide that electrical reference.
Keep the armored route strain-free and spin-free with a minimum 35 mm bend radius. Fix it at recurring short distances and keep the cable and connector clear of all rotating parts.
Do not shorten the PR6423 extension path. If cable remains after routing, roll the excess with a diameter of at least 100 mm and leave enough reserve for thermal expansion of the machine.
Read the complete code, not only the PR6423 family name. For PR6423/012-140, the order positions identify M10x1 thread, armored cable, 45 mm sensor length, no adapter plug, 10 m total cable and a LEMO end; each of those fields must match the installation.
The converter turns the probe response into the output voltage used by the monitoring electronics and provides the reference used for gap adjustment. The converter must also be adjusted for the target material, so a sensor-only check cannot confirm the complete measurement chain.
Do not shorten the configured cable path. Route it without strain or twist, and roll any excess at a diameter of at least 100 mm while maintaining the 35 mm minimum bend radius required by the armored cable.
Connect the complete sensor-converter chain and observe converter output voltage while moving the threaded sensor toward the target. Adjust the final position for the measurement task, then secure the nuts without exceeding the 15 Nm fastening limit.
A flexible holder, scratched or corroded target track, nearby metal, excessive tilt and a cable that is repeatedly moved can all change the electrical response without representing real shaft motion. The installation must therefore control both the geometry around the tip and the mechanical route behind it.
Other electrically conductive materials can be used only with the corresponding measuring-chain adjustment. The standard calibration is based on 42CrMo4 / SAE 4140, so changing the material without matching the converter calibration changes the measurement relationship.
Moore Automation coordinates industrial automation enquiries by exact manufacturer and model code. The requested part number, quantity, available identification photographs and required documentation are kept together so close variants remain separate during review.
A named account contact coordinates quotation information, requested documents and shipment communication. When delivery is arranged, available carrier and tracking details can be supplied through the same enquiry record.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found