Sensor input
A3120/022-000 receives two independent bearing-vibration signals and keeps their measurement paths separate.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Emerson AMS A3120/022-000 Bearing-Vibration Monitor |
| Item NO. | 2945395 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | EMERSON |
| Brand | EMERSON |
| Creation Time | 2026-11-26 |
Two-channel bearing-vibration monitoring
Exact order code: AMS 3120 dual-channel monitor in the /022-000 configuration.
The Emerson AMS A3120/022-000 functions as a two-channel bearing-vibration monitor in the AMS 3120 machinery-monitoring family. It accepts two vibration-sensor signals, processes each channel against configured measurement settings and exposes the resulting values, status and alarms to the plant monitoring boundary.
Within A3120/022-000, selectable high-pass and low-pass filters define the frequency band before the measured value is compared with configured limits. The front status indications and buffered outputs make the channel state observable without interrupting the sensor path.
Power for A3120/022-000 enters as a nominal 24 VDC supply. The enclosure provides current outputs, relay contacts and serial communication separately from the sensor inputs, so field wiring can keep low-level vibration signals apart from power and switching circuits.
| Technical Item | A3120/022-000 |
|---|---|
| Brand | Emerson AMS |
| Product Type | Dual-channel bearing-vibration monitor |
| Brand Country | United States |
| Measurement Channels | 2 |
| High-Pass Filter | 5 / 10 / 15 Hz |
| Low-Pass Filter | 50 to 1500 Hz |
| Nominal Supply Voltage | Nominal 24 VDC |
| Permissible Supply Range | 18 to 31.2 VDC |
| Power Consumption | Maximum 6 W |
| Current Outputs | Two, 0/4 to 20 mA |
| Relay Outputs | Five make contacts |
| Relay Contact Limit | 48 VDC, 1 A, 50 W |
| Mounting | Wall mount |
| Housing / Weight | Aluminium, approximately 1300 g |
Each channel follows the same input-processing-alarm path while retaining its own measurement settings and outputs.
A3120/022-000 receives two independent bearing-vibration signals and keeps their measurement paths separate.
The selected high-pass and low-pass filters remove frequencies outside the configured measurement band.
Each filtered signal is converted into the configured vibration value and checked against its channel limits.
Channel condition is available through indication, buffered signal access and configured outputs.
The monitor separates continuous measurement outputs from discrete alarm decisions so each destination receives the form it expects.
Buffered connectors expose the sensor-related signal for observation without changing the input circuit.
Two 0/4–20 mA outputs carry configured measurement values to external analogue inputs.
Five make contacts switch configured states subject to the relay contact limits.
The RS-485 interface carries configured monitor data separately from the hardwired outputs.
Trace both A3120/022-000 sensor leads to their assigned inputs and compare each configured range with the installed transducer. Verify the buffered signals and channel indications before enabling any alarm outputs.
The A3120/022-000 current loop follows the configured measurement scaling, not the raw buffered signal. Review the selected variable, the 0–20 or 4–20 mA mode and the external loop burden.
Keep A3120/022-000 relay circuits away from its low-level sensor and buffered-signal cables because contact switching can introduce noise. Apply the published grounding arrangement consistently at both channel routes.
Set the A3120/022-000 high-pass and low-pass limits around the mechanical frequency band that must be observed. A band that excludes the expected machine frequencies can leave healthy hardware reporting a misleadingly low value.
Before replacing A3120/022-000, retain both sensor types, measurement ranges, alarm setpoints, filter selections and output scaling with the full model code. Those settings define behaviour that is not visible from the enclosure alone.
Measure the A3120/022-000 supply at the monitor and confirm that it remains within 18 to 31.2 VDC. If only one channel is abnormal after the common supply is verified, continue with that sensor, cable and channel configuration.
A Moore Automation enquiry can include manufacturer-code review, quotation preparation and requested product literature. Quantities, identification photographs and document requirements are collected before commercial information is prepared.
After an order progresses, the assigned manager relays available lead-time, packing, carrier and tracking details through the same communication route.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found