Signal entry
UT55A-001-11-00 receives the field signal on the universal input terminals selected for its sensor type.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Yokogawa UT55A-001-11-00 Digital Indicating Controller |
| Item NO. | 2945399 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | YOKOGAWA |
| Brand | YOKOGAWA |
| Creation Time | 2026-11-26 |
Single-loop control with RS-485 communication
Exact suffix: standard control, RS-485 communication, fixed type code and black case.
Designed for panel operation, Yokogawa UT55A-001-11-00 is a digital indicating controller in the UTAdvanced family. It accepts a selected process input, compares the measured value with the active setpoint and drives the configured control output while the front display presents process, setpoint and operating status information.
The universal input of UT55A-001-11-00 is assigned in software for thermocouple, RTD, mV, voltage or current service. Input linearisation and control calculation occur before the output stage, so the terminal wiring, input type parameter and engineering range must describe the same field signal.
Suffix code 001-11-00 gives UT55A-001-11-00 an RS-485 communication interface in addition to its local panel operation. Communication wiring uses its own terminals and reference, while the controller supply, sensor wiring and output circuits remain separated according to the terminal diagram.
| Technical Item | UT55A-001-11-00 |
|---|---|
| Brand | Yokogawa |
| Product Type | Digital indicating controller |
| Brand Country | Japan |
| Control Structure | Single-loop PID or ON/OFF |
| Primary Input | Universal TC / RTD / mV / V / mA |
| Communication | RS-485, 2-wire or 4-wire |
| Maximum Communication Rate | 38.4 kbps |
| Power Supply | 100 to 240 VAC |
| Front Panel Size | 96 × 96 mm |
| Panel Cutout | 92 × 92 mm nominal |
| Panel Thickness | 1 to 10 mm |
| Operating Temperature | -10 to +50 °C |
| Case Colour | Black |
| Mounting | Panel mount with top and bottom brackets |
A usable control loop depends on the terminal signal, configured input type and control algorithm describing the same process variable.
UT55A-001-11-00 receives the field signal on the universal input terminals selected for its sensor type.
The controller converts the electrical value through the configured thermocouple, RTD or analogue-input characteristic.
The measured value and active setpoint enter the selected PID or ON/OFF calculation.
The configured control output changes according to the calculation, operating mode and output limits.
The controller shares one enclosure, but its power, input and communication circuits have different wiring roles and noise exposure.
The 100–240 VAC supply powers the instrument and is checked before the controller is energised.
Low-level thermocouple, RTD or analogue wiring follows the selected input diagram and polarity.
RS-485 uses the suffix-provided terminals, correct two- or four-wire arrangement and consistent station settings.
Top and bottom brackets clamp the 96 mm controller into the cutout without deforming the case.
On UT55A-001-11-00, compare the configured input range with the direct or reverse control action. A correctly scaled measurement still drives the output in the wrong direction when the action setting does not match the heating or cooling process.
A change to UT55A-001-11-00 requires comparison of the complete suffix, terminal wiring, output hardware, RS-485 requirement and stored parameters. Another UT55A can share the family name without sharing those interfaces.
If UT55A-001-11-00 continues to measure and control correctly from its front panel, investigate the communication path separately. Check station address, baud rate, parity, two- or four-wire selection and the RS-485 reference.
Route thermocouple wiring for UT55A-001-11-00 away from supply and switching conductors because the sensor voltage is small. Use the correct extension cable and preserve its polarity to the input terminals.
An input error on UT55A-001-11-00 usually indicates that sensor type, terminal assignment, polarity or software range do not agree. Correct that relationship before changing PID or output parameters.
For side-by-side UT55A-001-11-00 mounting, apply the published panel-cutout spacing and account for heat from adjacent instruments. The brackets must engage the panel while leaving the rear terminals accessible.
Customers work with one named account manager instead of passing an enquiry between unrelated departments. That contact gathers the complete product code, quantity and available nameplate evidence before responding.
A broad stock and sourcing network supports quick commercial review, while close variants remain separate rather than being treated as automatic substitutes.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found