Oscillator excitation
DS822.OD110 energises the eddy-current probe circuit through the matched coaxial path.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Bruel & Kjaer Vibro DS822.OD110 Oscillator/Demodulator Driver |
| Item NO. | 2945409 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | OTHER PRODUCTS |
| Brand | OTHER PRODUCTS |
| Creation Time | 2026-11-26 |
Driver stage for a 2 mm eddy-current measuring chain
The driver receives the matched sensor or extension-cable response and produces the monitoring output.
Bruel & Kjaer Vibro uses DS822.OD110 as the oscillator/demodulator driver in a ds822 non-contact displacement sensor system. It excites the matched eddy-current probe circuit, receives the probe-and-cable response and converts changing target gap into the DC output used by the monitoring channel.
The complete measurement chain around DS822.OD110 consists of a probe, optional extension cable and driver with a nominal combined length of 5 m or 10 m. Cable impedance and system length belong to the calibration boundary, so unmatched components alter the relationship between physical gap and output voltage.
Power enters DS822.OD110 from a protected -24 VDC SELV supply, while the output and common lines connect to the monitoring electronics through the published four-wire arrangement. The driver is electrically isolated from neighbouring metalwork by its mounting adapter and is installed outside the probe measuring location.
| Technical Item | DS822.OD110 |
|---|---|
| Brand | Bruel & Kjaer Vibro |
| Product Type | Oscillator/demodulator driver |
| Brand Country | Denmark |
| Sensor System | ds822 non-contact eddy-current |
| Measurement Variable | Distance / displacement |
| Nominal System Length | 5 m or 10 m |
| Linear Measuring Range | 2 mm |
| Approximate Distance Range | 0.4 to 2.4 mm |
| Nominal Supply | -24 VDC |
| Supply Range | -18 to -28 VDC |
| Output Signal | 0 V to approximately UB + 2 V |
| Power Consumption | Maximum 12 mA |
| Output Impedance | 50 Ω |
| Driver Protection | IP20 |
| Driver Dimensions | 26.5 × 83 × 60 mm |
The driver is the active conversion stage between the passive sensing geometry and the monitor input.
DS822.OD110 energises the eddy-current probe circuit through the matched coaxial path.
Distance to the conductive surface changes the electromagnetic loading at the sensor tip.
The driver converts the changed probe response into a DC voltage proportional to gap over the calibrated range.
Output, common and supply conductors connect the driver to the downstream monitoring electronics.
The chain is positioned with the rotor stationary so the available linear range remains on both sides of the normal gap.
Use the matched probe, extension cable where required, and DS822.OD110 for the intended 5 m or 10 m nominal length.
Observe the GAP voltage at the driver output while the target remains stationary.
Move the probe in its holder until the output reaches the required operating point inside the linear range.
Secure the sensor without moving its tip, then confirm the final gap voltage and cable support.
DS822.OD110 belongs to one calibrated probe-and-cable length, so changing only the extension cable can alter the gap transfer relationship. Match the electrical characteristics and nominal 5 m or 10 m chain even when the connectors physically fit.
Measure the -18 to -28 VDC supply and driver current at DS822.OD110 before disturbing the probe. If power is correct, continue with the coaxial chain, connector condition and stationary-rotor gap voltage.
Mount DS822.OD110 with the specified adapter or foot so its housing remains electrically isolated from nearby metalwork. Preserve the required clearance from other conductive housings.
Keep the DS822.OD110 probe path separated from power cables because it is part of the measurement circuit. Support the coaxial cable and maintain its minimum bending radius to prevent interference and mechanical damage.
A replacement DS822.OD110 record must include the driver code, nominal chain length, probe and extension-cable codes, target material and normal gap voltage. Those facts define the calibrated chain more completely than the driver label.
After bracket work, stop the rotor and observe the DS822.OD110 GAP voltage while repositioning the probe. Lock the bracket and verify that tightening has not shifted the operating point.
Incoming-part checks focus on visible manufacturer identification, order-code markings and the stated product condition. The recorded item is kept aligned with the commercial offer before packing and dispatch.
Warranty scope and applicable commercial terms are presented with the quotation, allowing the customer to review the coverage attached to that specific supply.
Moore Automation Sales Team