mV path
A2SAT105-S000 measures a low-level voltage directly across the configured input terminals.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Yokogawa A2SAT105-S000 mV/Thermocouple/RTD Input Adaptor |
| Item NO. | 2945415 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | YOKOGAWA |
| Brand | YOKOGAWA |
| Creation Time | 2026-11-26 |
Low-level temperature and resistance input adaptor
Exact suffix uses the A2SAT105 adaptor body with the S000 terminal/configuration option.
For CENTUM VP N-IO hardware, Yokogawa A2SAT105-S000 terminates one mV, thermocouple or RTD field input. Mounted on the A2BN3D base plate, the adaptor converts that low-level signal into the data format read by the connected N-IO module.
For thermocouple service, A2SAT105-S000 measures the thermoelectric voltage and uses the reference-junction temperature sensor located on the matching base plate. RTD service instead supplies the defined measuring current through a three-wire circuit so equal lead resistance can be compensated in the conversion.
The input of A2SAT105-S000 is galvanically separated from the system boundary and is configured in software for the actual mV, thermocouple, RTD or potentiometer range. Low-level analogue wiring is kept out of multicore cables shared with digital I/O because capacitive coupling can alter measurement accuracy.
| Technical Item | A2SAT105-S000 |
|---|---|
| Brand | Yokogawa |
| Product Type | mV / thermocouple / RTD input adaptor |
| Brand Country | Japan |
| mV Range | -50 to +150 mV |
| Thermocouple Types | J, K, E, B, R, S, T, N |
| RTD Types | Pt100, Pt200, Pt500, JPt100, Ni100, Ni120 |
| RTD Wiring | 3-wire |
| RTD Resistance Ranges | 0–400 Ω or 0–2000 Ω |
| Data Update Period | 124 ms adaptor alone |
| Burnout Detection | UP, DOWN or OFF |
| Input-to-System Withstand | 1500 VAC for 1 minute |
| Mounting | A2BN3D base plate for adaptor |
| 24 VDC Consumption | Maximum 12 mA |
| 5 VDC Internal Consumption | Maximum 10 mA |
| Weight | 0.10 kg or less |
The same adaptor accepts several sensor families, but each uses a different electrical relationship and software range.
A2SAT105-S000 measures a low-level voltage directly across the configured input terminals.
The adaptor combines thermoelectric voltage with the base-plate reference-junction temperature.
A defined current passes through the three-wire resistance circuit and the converter compensates equal lead resistance.
The converted value updates through the N-IO module after the software input type and range are applied.
Accuracy depends on the thermal reference at the terminal boundary and on keeping the low-level signal separate from other circuits.
The thermocouple reference-junction sensor is located on the compatible A2BN3D base plate.
Adjacent heat sources can change the reference-junction accuracy even when the thermocouple itself is healthy.
The published withstand boundaries separate the field input from the system and neighbouring adaptors.
Thermocouple, RTD and mV leads are routed away from digital switching conductors and shared multicore paths.
For an offset thermocouple value on A2SAT105-S000, check sensor type, polarity and the base-plate reference-junction environment. Heat from adjacent adaptors or incorrect extension wire can shift a stable value without producing an open-circuit alarm.
Changing A2SAT105-S000 from RTD to thermocouple service requires new terminal wiring, the matching software input type and range, and the correct base plate. RTD measuring current and thermocouple compensation follow different electrical paths.
A2SAT105-S000 burnout detection can drive an open-circuit value upward, downward or leave the function disabled. Verify the selected direction before that converted value is used by alarm logic.
Do not share the A2SAT105-S000 low-level cable with digital I/O because switching signals can couple capacitively into the measurement. Use a separate shielded route appropriate to the configured sensor type.
After RTD rewiring, A2SAT105-S000 cannot compensate correctly when lead resistance is unequal or the matched leads occupy the wrong terminals. Check the specified pair and every field joint before changing the range.
Record the A2BN3D base-plate code and style, connected N-IO module, terminal option and software range with A2SAT105-S000. The adaptor is one part of that assembled input path, not a stand-alone transmitter.
Extensive multi-brand inventory and global sourcing allow Moore Automation to cover automation components from active systems as well as older installed bases. This range includes control, motion, instrumentation and machinery-monitoring hardware.
Clear order-code records, responsive commercial handling and coordinated international delivery create a direct path from the initial requirement to the supplied line item.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found