Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BOSCH >Bosch Rexroth TDM4.1-020-300-W0 / TDM7.1-030-300-W1 Modular AC Servo Drive Controllers
Bosch Rexroth TDM4.1-020-300-W0 / TDM7.1-030-300-W1 Modular AC Servo Drive Controllers

Bosch Rexroth TDM4.1-020-300-W0 / TDM7.1-030-300-W1 Modular AC Servo Drive Controllers Item NO.: 2944593

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bosch Rexroth TDM4.1-020-300-W0 / TDM7.1-030-300-W1 Modular AC Servo Drive Controllers
Item NO. 2944593
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BOSCH
Brand BOSCH
Creation Time 2026-11-24

Bosch Rexroth TDM4.1-020-300-W0 / TDM7.1-030-300-W1 Modular AC Servo Drive Controllers

Bosch Rexroth TDM4.1-020-300-W0 / TDM7.1-030-300-W1 Modular AC Servo Drive Controllers

Product facts

Product Information

TDM4.1-020-300-W0 and TDM7.1-030-300-W1 are modular AC servo drive controllers that operate from a common 300 V DC intermediate circuit. Each controller combines current regulation, command processing, motor feedback and a programming module within an INDRAMAT drive package.

TDM4.1-020-300-W0 is a naturally cooled 20 A controller with 15 A continuous current and 6 kW type power, whereas TDM7.1-030-300-W1 is a forced-ventilation 30 A controller with 12 A continuous current and 9 kW type power. Their DC-bus tolerances and signal-supply loads also belong to different module families.

The cooling suffixes are functional parts of TDM4.1-020-300-W0 and TDM7.1-030-300-W1: W0 uses natural convection, while W1 requires a fan unit. Both controllers exchange current commands, actual-current signals and motor feedback through the installed programming and interface hardware.

Exact model data

Technical Data

Specification TDM4.1-020-300-W0 TDM7.1-030-300-W1
Brand Bosch Rexroth Bosch Rexroth
Product family TDM 4.1 TDM 7.1
Product type AC servo drive controller AC servo drive controller
Cooling Natural convection Forced ventilation; fan unit required
Type current 20 A 30 A
Peak current 20 A 30 A
Continuous current 15 A 12 A
DC intermediate circuit 300 V ±15% 300 V ±10%
Type power 6 kW 9 kW
Power loss at continuous current 110 W 135 W
Mass 8 kg 6.5 kg
+24 V signal-processing load 400 mA 250 mA
+15 V test-voltage load 150 mA 150 mA
−15 V test-voltage load 60 mA 75 mA
Protection IP10 IP10
System function

Servo Current Processing

Both controllers turn low-level commands and feedback into regulated motor current, but their internal signal scales belong to different TDM families.

Path 01

Command input

The command path enters the installed interface and programming module before it becomes a current or speed request.

Path 02

Actual-current signal

The power section returns an actual-current value to the control electronics so motor torque can be regulated continuously.

Path 03

Motor feedback

Feedback closes the servo loop and remains separate from the high-current A1/A2/A3 motor conductors.

System function

Cooling and Module Arrangement

The suffix determines how power-stage heat leaves the controller and therefore changes the surrounding cabinet arrangement.

Path 01

W0 convection

The TDM4.1 frame releases heat by natural convection and requires clear vertical airflow around the module.

Path 02

W1 fan unit

The TDM7.1 frame depends on its assigned fan unit; airflow and fan supply are part of the operating assembly.

Path 03

Modular bus

Busbars, bus connection and signal terminals continue through the drive package while each axis retains its own programming module.

Practical checks

Product Questions

01How should cabinet airflow be arranged for the two cooling methods represented by TDM4.1-020-300-W0 and TDM7.1-030-300-W1?

When checking TDM4.1-020-300-W0 and TDM7.1-030-300-W1, reserve convection space around the TDM4.1 unit and a clear fan path around the TDM7.1 unit.

02If a fan indication is absent, how does the cooling requirement differ across TDM4.1-020-300-W0 and TDM7.1-030-300-W1?

When checking TDM4.1-020-300-W0 and TDM7.1-030-300-W1, treat forced ventilation as mandatory for the TDM7.1 W1 frame while the TDM4.1 W0 frame has no assigned fan unit.

03Before the modular bus of TDM4.1-020-300-W0 and TDM7.1-030-300-W1 is inspected, what must be safely isolated?

When documenting TDM4.1-020-300-W0 and TDM7.1-030-300-W1, inspect DC-bus bars, bus connectors and signal terminals only after the power is safely isolated.

04Which electrical and cooling differences keep TDM4.1-020-300-W0 and TDM7.1-030-300-W1 from being treated as interchangeable controllers?

Before work begins on TDM4.1-020-300-W0 and TDM7.1-030-300-W1, use the complete TDM4.1 and TDM7.1 type plates because current scale, cooling and DC-bus tolerance are not interchangeable.

05When torque becomes unstable on TDM4.1-020-300-W0 and TDM7.1-030-300-W1, which control and feedback paths should be reviewed first?

With TDM4.1-020-300-W0 and TDM7.1-030-300-W1, check the command source, programming module, actual-current path and motor feedback before comparing current ratings.

06How does the programming module affect the servo-loop behavior of TDM4.1-020-300-W0 and TDM7.1-030-300-W1?

For a site record covering TDM4.1-020-300-W0 and TDM7.1-030-300-W1, keep the installed programming module with its own axis because it defines the controller and motor scaling used by that servo loop.

Protected controller packing and tracking

Shipping Services

Moore Automation

https://www.mvme.cn

Moore Automation coordinates packing and shipment information for industrial controllers with attention to attached programming modules, plug-in terminals and cooling accessories.

For this TDM pair, quantities, destination, packaging notes and tracking references can remain separated by exact model so a fan-equipped unit is not confused with a convection-cooled frame.

Protective packingTerminals and modules kept supported
Accessory checkFan-unit record retained where required
Carrier optionsShipment route coordinated per enquiry
Tracking updateReferences shared after dispatch

Sales Enquiries

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.