Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BOSCH >Bosch Rexroth HCS02.1E-W0028-A-03-NNNN IndraDrive C Compact Converter
Bosch Rexroth HCS02.1E-W0028-A-03-NNNN IndraDrive C Compact Converter

Bosch Rexroth HCS02.1E-W0028-A-03-NNNN IndraDrive C Compact Converter Item NO.: 2942446

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bosch Rexroth HCS02.1E-W0028-A-03-NNNN IndraDrive C Compact Converter
Item NO. 2942446
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BOSCH
Brand BOSCH
Creation Time 2026-11-18

Bosch Rexroth HCS02.1E-W0028-A-03-NNNN IndraDrive C Compact Converter
Bosch Rexroth · IndraDrive C

Bosch Rexroth HCS02.1E-W0028-A-03-NNNN
IndraDrive C Compact Converter

01

Product Description

Bosch Rexroth HCS02.1E-W0028-A-03-NNNN is an IndraDrive C compact converter for operating a single axis. Its power section receives the mains supply, establishes the DC bus and converts that DC energy into a controlled three-phase output for a synchronous or asynchronous motor.

Inside HCS02.1E-W0028-A-03-NNNN, L1, L2 and L3 feed the rectifier before the charging-current limiter and braking-resistor circuit act on the DC bus. The 0.27 mF DC-bus capacitance sits between those input circuits and the inverter stage; A1, A2 and A3 carry the inverter output to the motor, while L+ and L- expose the DC-bus connection.

The HCS02.1E-W0028-A-03-NNNN suffix NNNN identifies a version without the additional internal control-voltage supply used by NNNV variants. Control power therefore enters through the 24 V input for the control section and connected control-side loads, separately from the three-phase mains path handled by the converter power section.

Bosch Rexroth HCS02.1E-W0028-A-03-NNNN mains, DC bus and inverter block diagram
02

Technical Specifications

Attribute HCS02.1E-W0028-A-03-NNNN
01Brand Bosch Rexroth
02Product name IndraDrive C Compact Converter
03Series IndraDrive C / HCS02
04Product type Compact single-axis converter
05Mains connection voltage 3 × AC 200...500 V ±10%
06Rated input current 13.0 A
07Output voltage 3 × AC 0...530 V
08Output current at 4 kHz 12.0 A continuous / 28.3 A maximum
09DC bus capacitance 0.27 mF
10Rated DC bus power 5.10 kW with choke / 5.10 kW without choke
11Control-voltage input 24 V ±20%
12Operating temperature 0...40 °C nominal / 0...55 °C with derating
13Cooling and mounting Forced ventilation / mounting position G1
14Housing size and mass 352 × 65 × 206 mm (H × W × D) / 3.80 kg
15Degree of protection IP20
03

Product Functions: From Mains to Motor

The HCS02.1E-W0028-A-03-NNNN power section keeps input conversion, DC-bus energy handling and motor-output switching in one compact IndraDrive C unit.

01

Rectification and controlled charging

The HCS02.1E-W0028-A-03-NNNN routes the three-phase mains input through its rectifier. The charging-current limiting path controls how the DC-bus capacitors are energized instead of applying the input directly to an uncharged bus.

02

DC-bus and braking path

Between the input and inverter stages, the HCS02.1E-W0028-A-03-NNNN stores energy in its DC-bus capacitance and switches the integrated braking-resistor circuit when the configured braking threshold is reached.

03

Motor-output conversion

The inverter stage of HCS02.1E-W0028-A-03-NNNN switches DC-bus energy to A1, A2 and A3. The resulting three-phase output serves the connected motor while L+ and L- retain the separate DC-bus connection.

04

Installation Highlights

Installation of HCS02.1E-W0028-A-03-NNNN is organized around airflow, separate power paths and the limits attached to the exact W0028 frame.

Keep the G1 airflow path open

Mount HCS02.1E-W0028-A-03-NNNN in position G1 with forced ventilation. The specified minimum clearance is 80 mm above and below the housing so intake and exhaust air can pass through the device.

Separate mains, control and motor wiring

For HCS02.1E-W0028-A-03-NNNN, connect the three-phase mains path at L1/L2/L3, the motor path at A1/A2/A3 and the external control supply at the 24 V control-voltage input. L+ and L- remain the DC-bus terminals.

Match conductors to the W0028 data

The HCS02.1E-W0028-A-03-NNNN input is rated at 13.0 A, while its 4 kHz output limits are 12.0 A continuous and 28.3 A maximum. Conductor and protection selection must follow the W0028 row rather than an adjacent HCS02 frame.

05

Frequently Asked Questions

How can HCS02.1E-W0028-A-03-NNNN be distinguished from the NNNV version before installation?

Check the full type code on HCS02.1E-W0028-A-03-NNNN: the final NNNN means no additional design, whereas NNNV identifies the version with a 24 V supply derived from the DC bus and external source.

Where does control voltage enter HCS02.1E-W0028-A-03-NNNN?

The control section of HCS02.1E-W0028-A-03-NNNN uses the 24 V control-voltage input. The specified input range is 24 V ±20%, and control-side consumption is separate from the L1/L2/L3 power path.

Which terminals carry mains and motor power on HCS02.1E-W0028-A-03-NNNN?

On HCS02.1E-W0028-A-03-NNNN, L1, L2 and L3 receive the mains supply, while A1, A2 and A3 carry the controlled three-phase output to the motor. L+ and L- are the DC-bus connection.

Why must the switching frequency be checked when loading HCS02.1E-W0028-A-03-NNNN?

The continuous output current of HCS02.1E-W0028-A-03-NNNN changes with switching frequency: it is 12.0 A at 4 kHz, 9.2 A at 8 kHz, 5.1 A at 12 kHz and 4.4 A at 16 kHz. The active switching frequency therefore belongs in the load check.

What should be checked if HCS02.1E-W0028-A-03-NNNN is running above the nominal ambient range?

HCS02.1E-W0028-A-03-NNNN carries nominal data from 0 to 40 °C. Operation up to 55 °C requires reduction of continuous DC-bus power, braking power and continuous output current, while the forced-air path and 80 mm top and bottom clearances remain open.

What limits matter before connecting HCS02.1E-W0028-A-03-NNNN to a common DC bus?

For HCS02.1E-W0028-A-03-NNNN, use the W0028 DC-bus data: 5.10 kW rated power with or without the assigned choke, 0.27 mF internal capacitance and up to 5.00 mF allowed external capacitance when the assigned mains choke is used.

06

Customer Support

Moore Automation customer support team reviewing an industrial component

Moore Automation

https://www.mvme.cn

Moore Automation handles enquiries for PLC, DCS and industrial automation components from established manufacturers. Send the manufacturer, complete model number, quantity and delivery destination so the request can be recorded against exact identifiers.

Product-label photographs, the complete order code and requested documentation help separate similar variants and keep the commercial enquiry tied to the correct item.

Exact model recordingProduct-label reviewMulti-brand enquiriesEmail and WhatsApp contact
07

Selected Products

  • Siemens 6ES7288-5AE01-0AA0
  • ABB 783F
  • Bently Nevada 330101-00-60-10-02-05
  • Allen-Bradley 1756-OB32E
  • Emerson IC695CPL410
  • GE IC660BBA026
  • Triconex 3664E
  • HIMA F6705
  • B&R X20AI2622
  • Bosch Rexroth DDS02.1-W100-D
  • Yokogawa PW484-50
  • Woodward 5453-754
  • ProSoft PLX31-MBTCP-SIE
  • Vibro-Meter 200-582-200-011
  • Motorola MVME2302
  • Siemens 6ES7288-5AQ01-0AA0
  • ABB BRC300
  • Bently Nevada 330102-00-20-10-02-00
  • Allen-Bradley 1756-OF8I
  • Emerson IC695CPS400
  • GE IC660BBA100
  • Triconex 3700A
  • HIMA F6706
  • B&R X20AI2632
  • Bosch Rexroth HCS01.1E-W0009-A-02-B-ET-EC-NN-L3-NN-FW
  • Yokogawa AAP135-S50
  • Woodward 8528-114
  • ProSoft PLX31-PND-MBS
  • Vibro-Meter 200-582-200-013
  • Motorola MVME2303
  • Siemens 6ES7288-5BA01-0AA0
  • ABB BRC400
  • Bently Nevada 330103-00-02-10-02-05
  • Allen-Bradley 1747-DTAM-E
  • Emerson IC695PNC001
  • GE IC660BBA101
  • Triconex 3703E
  • HIMA M3421
  • B&R X20AI4222
  • Bosch Rexroth HCS02.1E-W0054-A-03-NNNN
  • Yokogawa AAI841-H50
  • Woodward 8521-0070
  • ProSoft PLX31-PND-MBS4
  • Vibro-Meter 200-582-300-013
  • Motorola MVME2304
  • Siemens 6ES7288-7DP01-0AA0
  • ABB BRC410
  • Bently Nevada 330103-00-04-10-02-00
  • Allen-Bradley 2707-M232P3
  • Emerson IC695ETM001
  • GE IC660BBA103
  • Triconex 3704E
  • HIMA K9203A
  • B&R X20AI4632
  • Bosch Rexroth HCS03.1E-W0150-A-05-NNBV
  • Yokogawa S2SC70D-SA11010
  • Woodward 8561-701
  • ProSoft PLX32-MBTCP-PND
  • Vibro-Meter 200-582-500-013
  • Motorola MVME2304-0111

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.