Mains and DC bus
Power terminals establish the energy boundary before the output stage converts DC-bus energy into variable-frequency motor power.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Bosch Rexroth HCS01.1E-W0008-A-03-B-ET-EC-NN-L4-NN-FW / HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW IndraDrive Cs Compact Converters |
| Item NO. | 2944596 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | BOSCH |
| Brand | BOSCH |
| Creation Time | 2026-11-24 |
HCS01.1E-W0008-A-03-B-ET-EC-NN-L4-NN-FW and HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW are IndraDrive Cs compact converters that combine the power section and control section in a narrow cabinet-mounted drive. Each unit carries the mains input, DC bus, motor output, encoder connection and Ethernet-based control interface within one housing.
The 0008 and 0013 power fields distinguish HCS01.1E-W0008-A-03-B-ET-EC-NN-L4-NN-FW from HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW, while the 03 and 02 blocks keep their mains-voltage classes separate. The full B/ET and E/S3 option blocks remain part of the exact control-section identity.
Both HCS01.1E-W0008-A-03-B-ET-EC-NN-L4-NN-FW and HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW use a 24 V control supply and a compact mounting footprint with defined top and bottom airflow clearances. The EC encoder interface and remaining option positions must be read from the complete code rather than inferred from the power class alone.
| Specification | HCS01.1E-W0008-A-03-B-ET-EC-NN-L4-NN-FW | HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW |
|---|---|---|
| Brand | Bosch Rexroth | Bosch Rexroth |
| Product family | IndraDrive Cs HCS01.1E | IndraDrive Cs HCS01.1E |
| Product type | Compact converter | Compact converter |
| Power-section field | W0008 | W0013 |
| Mains-voltage class | 03 | 02 |
| Control-section block | B / ET | E / S3 |
| Encoder interface | EC | EC |
| Safety-option field | L4 | NN |
| Control voltage | 24 V DC ±20% | 24 V DC ±20% |
| Mounting form | Compact cabinet mounting | Compact cabinet mounting |
| Housing group | W0005/W0008/W0013 compact frame | W0005/W0008/W0013 compact frame |
| Cooling path | Vertical cabinet airflow | Vertical cabinet airflow |
| Connection groups | Power, control, encoder and communication | Power, control, encoder and communication |
| Firmware field | FW | FW |
The HCS01 housing places mains conversion, DC-bus energy and motor output beside the control electronics without merging their wiring functions.
Power terminals establish the energy boundary before the output stage converts DC-bus energy into variable-frequency motor power.
The W0008 and W0013 classes share a mounting family, but the full type codes keep their power and mains-voltage identities separate.
Top and bottom clearances create a vertical cooling path through the narrow drive and must remain open inside the cabinet.
The option blocks identify how commands, feedback and safety functions enter the compact converter.
ET and S3 belong to different control-section records and therefore cannot be treated as cosmetic suffixes.
EC identifies the encoder interface position used by the motor-feedback connection and control loop.
L4 versus NN remains part of the exact type identity and should be read from the complete label rather than guessed from the frame.
On HCS01.1E-W0008-A-03-B-ET-EC-NN-L4-NN-FW and HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW, read L4 or NN directly from the complete type plate and match the external safety wiring to that installed option.
When checking HCS01.1E-W0008-A-03-B-ET-EC-NN-L4-NN-FW and HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW, measure the installed frame and preserve the required top, bottom and side clearances shown for the compact housing group.
To keep HCS01.1E-W0008-A-03-B-ET-EC-NN-L4-NN-FW and HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW unambiguous, match the EC interface, motor encoder and cable identity before applying feedback settings.
Before work begins on HCS01.1E-W0008-A-03-B-ET-EC-NN-L4-NN-FW and HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW, use the 03 and 02 code blocks with their complete model strings because the mains class is part of the power-section identity.
With HCS01.1E-W0008-A-03-B-ET-EC-NN-L4-NN-FW and HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW, check the exact B/ET or E/S3 control section, 24 V control supply, network cabling and device address.
For a site record covering HCS01.1E-W0008-A-03-B-ET-EC-NN-L4-NN-FW and HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW, treat B/ET with L4 and E/S3 with NN as different communication and safety arrangements even when the converters share a compact housing family.
Moore Automation supports compact-drive enquiries by collecting the manufacturer, complete model string, quantity and destination before preparing a commercial response.
For these HCS01 records, product information, document requests, quotation notes, packing details and tracking updates can remain tied to the correct power and control-section option blocks.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found