Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BENTLY NEVADA>Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 | 1900/65A General Purpose Equipment Monitor
Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 | 1900/65A General Purpose Equipment Monitor

Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 | 1900/65A General Purpose Equipment Monitor Item NO.: 2925777

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 | 1900/65A General Purpose Equipment Monitor
Item NO. 2925777
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BENTLY NEVADA
Brand Bently Nevada
Creation Time 2026-10-21

Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 | 1900/65A General Purpose Equipment Monitor | Moore Automation
Bently Nevada · Machinery Monitoring HardwareMoore Automation · Technical Record

Bently Nevada · 1900/65A General Purpose Equipment Monitor

Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 | 1900/65A General Purpose Equipment Monitor

RELAY LOGIC · 4–20 MA RECORDING · CONFIGURABLE SENSOR INPUTS

Complete model · 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01
01

Product Description

The Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 records a second exact 1900/65A option pair for a general-purpose equipment monitor. It combines four transducer inputs, four temperature inputs and configurable alarm/output handling in the same monitor family.

On Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01, the transducer channels accept the supported vibration, position and speed sensor types while the temperature channels process thermocouple or RTD signals. Relay states and recorder values are generated from the configured variables.

The 01-01-03-00-00 and 01-01-03-00-01 suffix records on Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 must remain visible during configuration because the final fields are part of the exact option identity.

02

Technical Data

Brand
Bently Nevada
Complete models
1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01
Product type
General Purpose Equipment Monitor
Transducer inputs
4
Temperature inputs
4
Relay outputs
6
Recorder outputs
4 × 4–20 mA
Buffered output
Dedicated channel buffer
Speed variables
Up to 4
Speed full scale
100–100,000 rpm
Input impedance
10 kΩ
Transducer frequency
1–600 Hz or 4–4000 Hz bands
Temperature channels
Type E/J/K/T and 2/3-wire RTDs
Units
°C or °F
Mounting
DIN rail, bulkhead or weatherproof enclosure
Communications
Modbus/configuration software
Option record
01-01-03-00-00 and 01-01-03-00-01 retained exactly
03

Configuration and Programming

Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 depends on channel assignments and alarm logic, so the programming record must stay aligned with the exact suffix.
01

Channel assignment

Each transducer and temperature channel on Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 is assigned a sensor type, units and processing range.

02

Alarm setup

Alert and Danger thresholds, delays and relay behavior are configured from the variables selected for the monitor.

03

Output mapping

Recorder current outputs and the buffered output are mapped to chosen variables instead of assuming the same assignment for every 1900/65A option string.

04

Diagnostics and Protection

Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 exposes monitor status and alarm conditions so the configured relay and recorder paths can be checked.
01

OK status

The monitor evaluates each enabled variable and reports its OK condition before an alarm relay is allowed to represent a healthy state.

02

Alarm delay

Configured Alert and Danger delays prevent a transient variable from immediately changing the relay state on Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01.

03

Communication check

Front-panel, software and Modbus values allow the recorded variable, relay state and configuration to be compared during a diagnostic check.

05

Product Q&A

Why can Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 give the wrong relay response after a setting change?
For Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01, verify the source variable, Alert/Danger thresholds, delay and relay destination as one chain. Changing only the relay label can leave the external circuit tied to a different condition.
How should a 4–20 mA loop be traced on Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01?
Trace the selected sensor or temperature channel to its assigned recorder output on Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01, then compare the measured current with the monitor display. This identifies whether the fault is in channel mapping, output wiring or the receiving PLC.
What sensor mismatch can make Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 unusable?
The channel type on Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 must match the installed accelerometer, velocity, proximity, speed, thermocouple or RTD input. Selecting a different family changes the scaling and alarm calculation.
How can a customer tell a monitor fault from field wiring on Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01?
Compare the front-panel value, configuration-software value, Modbus value and relay state for Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01. Agreement inside the monitor with a missing external signal points toward recorder or field wiring.
Why must the final option field stay with Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01?
The final fields of Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 are part of the exact option records. Dropping them can cause the channel wiring, relay logic or approval check to be matched to the wrong monitor.
What is the quickest way to check an intermittent Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 alarm?
Review the channel OK state, alarm delay and configured source for Bently Nevada 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 before changing thresholds. The monitor can report a short input fault or delayed state that is not visible in the steady measurement value.
06

Alarm Configuration

Moore Automation

https://www.mvme.cn/

Moore Automation supports industrial automation, monitoring and instrumentation enquiries with complete model records and coordinated supply information.

The requested 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 record can stay linked to quantities, drawings and shipment details during the enquiry.

Exact model record

The complete 1900/65A-01-01-03-00-00 / 1900/65A-01-01-03-00-01 string stays visible in the enquiry.

Industrial scope

Moore Automation handles automation, monitoring and instrumentation records.

Order traceability

Quantities, drawings and shipment details remain tied to the model record.

Moore Automation

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.