Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>SIEMENS>Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 | S7-200 SMART DT16 / DT32 Digital I/O Modules
Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 | S7-200 SMART DT16 / DT32 Digital I/O Modules

Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 | S7-200 SMART DT16 / DT32 Digital I/O Modules Item NO.: 2926372

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 | S7-200 SMART DT16 / DT32 Digital I/O Modules
Item NO. 2926372
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category SIEMENS
Brand SIEMENS
Creation Time 2026-10-23

Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 | S7-200 SMART DT16 / DT32 Digital I/O Modules

Siemens · SIMATIC S7-200 SMART

Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 | S7-200 SMART DT16 / DT32 Digital I/O Modules

SECTION 01

Product Introduction

Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 are SIMATIC S7-200 SMART mixed digital modules with 24 V DC inputs and sourcing transistor outputs. DT16 adds eight inputs and eight outputs in a 45 mm body; DT32 doubles both channel sets in a 70 mm body.

Input circuits on Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 accept sink or source field devices, provide selectable filters in groups of four and isolate the field side from logic. The outputs use 20.4 to 28.8 V DC and switch in under 50 µs on and 200 µs off.

Output grouping distinguishes the two modules. Siemens 6ES7288-2DT16-0AA0 uses two commons limited to 3 A each, while Siemens 6ES7288-2DT32-0AA0 distributes sixteen outputs across three isolation groups and allows up to 6 A per common within individual point limits.

SECTION 02

Technical Information

Technical dossier 6ES7288-2DT16-0AA0 6ES7288-2DT32-0AA0
Brand Siemens
Product Type EM DT16 mixed digital I/O module EM DT32 mixed digital I/O module
Brand Country Germany
Dimensions (W × H × D) 45 × 100 × 81 mm 70 × 100 × 81 mm
Weight 179.7 g 257.3 g
Power Dissipation 2.5 W 4.5 W
Signal-Module Bus Current 145 mA 185 mA
Digital Inputs 8 16
Digital Outputs 8 sourcing MOSFET 16 sourcing MOSFET
Nominal Input 24 V DC at 4 mA
Output Supply 20.4 to 28.8 V DC
Output Current 0.75 A per point
Maximum per Common 3 A 6 A
Output Isolation Groups 2 3
Output Switching <50 µs on; <200 µs off
Maximum Output Cable 500 m shielded; 150 m unshielded
SECTION 03

Product Functions

Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 carry input states toward the CPU and return fast sourcing commands to DC loads through the same expansion module.

Input acquisition›Expansion-bus exchange›Sourcing load drive
01

Input acquisition

Eight or sixteen sink/source channels place 24 V DC field states into the assigned process-image addresses.

02

Expansion-bus exchange

The compatible CPU reads those states and sends output commands through the right-side module bus.

03

Sourcing load drive

The MOSFET stage applies positive DC to eight or sixteen loads whose return circuits are tied to the correct M reference.

SECTION 04

System Integration

Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 divide load current across defined commons so one supply path is not treated as an unlimited rail.

01

DT16 two-group plan

Each four-output group stays within its 3 A common limit while every point remains at or below 0.75 A.

02

DT32 three-group plan

Sixteen outputs are separated across three groups with the published 6 A common limit and connector allocation.

03

Field-supply separation

The 24 V output supply powers the loads; it is calculated independently from module-bus current and input sensing current.

SECTION 05

Frequently Asked Questions

Why does an output LED turn on but the load stay off on Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0?

Verify the 20.4 to 28.8 V DC field supply, the correct L+/M pair and the load return on Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0. The expansion bus carries the command but does not replace the field supply required by the sourcing output stage.

How can common overload be avoided on Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0?

For Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0, total the simultaneous load current by common as well as by point. Keep DT16 commons within 3 A and DT32 commons within 6 A while each channel remains at or below 0.75 A.

Why does Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 show several input changes when one field contact operates?

Inspect the shared input reference, cable routing and filter group on Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0. Coupled interference or a loose M conductor can affect multiple points that share the same terminal group.

Can Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 switch AC loads directly?

No. The transistor outputs on Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 are sourcing 24 V DC circuits. Use an appropriate interposing device when the final load requires AC or exceeds the module voltage and current envelope.

Which engineering records need revision during a size change from Siemens 6ES7288-2DT16-0AA0 to 6ES7288-2DT32-0AA0?

Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 differ in width, address count, connectors, isolation groups and bus current. Update the project hardware and field terminal plan; do not move the wiring as though the larger module were the same pinout.

Why can a fast output on Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 become unreliable on a long cable?

Compare the output cable on Siemens 6ES7288-2DT16-0AA0 / 6ES7288-2DT32-0AA0 with the 500 m shielded or 150 m unshielded limit and consider load capacitance and switching frequency. A cable that carries static commands can behave differently during rapid transitions.

SECTION 06

Shipping Services

Moore Automation

https://www.mvme.cn

Moore Automation links packing references, carrier details and tracking information to the confirmed industrial-part enquiry.

Packaging and handoff notes remain with the item and quantity, while tracking details are shared when the selected carrier provides them.

Packing recordItem and quantity referenced
Carrier handoffShipment details retained
Tracking updateNumber shared when available
www.mvme.cn
SECTION 08

Contact & Enquiry

Moore Automation

Discuss the exact product requirement

Use the direct contacts for product and delivery enquiries.

ManagerLeonia
Emailsales@mvme.cnWhatsApp+86 180 3017 5807

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.