Bently Nevada 1900-65A-01-01-02-00-00 1900/65A General Purpose Equipment Monitor
Eight-channel machinery monitoring with an attached display and bulkhead mount
Product Presentation
Continuous machinery protection is concentrated in Bently Nevada 1900-65A-01-01-02-00-00, a configured 1900/65A monitor with four dynamic transducer inputs and four temperature inputs. The channel set accepts acceleration, velocity and proximity measurements alongside thermocouple or RTD temperature points.
The option string on 1900-65A-01-01-02-00-00 selects a 110-220 VAC external supply, an attached display and bulkhead mounting. The final two 00 codes specify no additional approval option and no Modbus communication option, keeping the front display as the local information interface.
Protection outputs from 1900-65A-01-01-02-00-00 include six configurable relays, four 4-20 mA recorder outputs and a dedicated buffered output for the transducer channels. Configuration data is transferred through the built-in Ethernet connection and retained in non-volatile memory.
Engineering Specifications
| Technical Item | 1900-65A-01-01-02-00-00 |
|---|---|
| Brand | Bently Nevada |
| Product Type | General-purpose equipment monitor |
| Brand Country | United States |
| Power Option 01 | 110-220 VAC, 50-60 Hz external supply |
| Display Option 01 | Attached display, no extension cable |
| Mounting Option 02 | Bulkhead mount |
| Approval Option 00 | No additional approval option |
| Communications Option 00 | No Modbus gateway option |
| Dynamic Inputs | 4 configurable transducer channels |
| Temperature Inputs | 4 channels for Type E, J, K, T thermocouples or 2/3-wire RTDs |
| Output Set | 6 configurable relays; 4 recorder outputs at 4-20 mA; dedicated buffered output |
| Combined Envelope | 196.85 × 149.35 × 97.79 mm |
| Configuration Storage | Non-volatile memory; Ethernet file transfer |
Channel Processing and Protection Logic
Dynamic and temperature channels share one configurable protection engine.
1900-65A-01-01-02-00-00 processes four machinery transducer channels and four temperature channels in the same monitor. Each dynamic channel is assigned a sensor and measurement type, while the temperature channels accept the documented thermocouple or RTD wiring.
Variable processing
Dynamic channels in 1900-65A-01-01-02-00-00 can derive vibration, position, thrust or speed variables according to the configured channel type.
Status logic
OK, Alert and Danger states from 1900-65A-01-01-02-00-00 can be combined in relay logic without treating every channel as an identical measurement.
Relay, Recorder and Buffered Outputs
Six relays on 1900-65A-01-01-02-00-00 can open or close from configured OK, Alert and Danger conditions.
Four 4-20 mA outputs let 1900-65A-01-01-02-00-00 forward selected variables to external recording or control equipment.
The dedicated buffered connector on 1900-65A-01-01-02-00-00 exposes the transducer input signals for analysis.
Support Questions
What does the 01-01-02-00-00 option chain define on 1900-65A-01-01-02-00-00?
On 1900-65A-01-01-02-00-00, the sequence specifies external 110-220 VAC power, an attached display, bulkhead mounting, no added approval option and no Modbus option. Each pair belongs to a different order-matrix position and must stay in the supplied order.
Which sensor families can use the four dynamic inputs of 1900-65A-01-01-02-00-00?
1900-65A-01-01-02-00-00 can configure its dynamic channels for compatible accelerometers, velocity sensors or proximity sensors. The selected channel type controls the sensor interface and the variables derived from that signal.
Why will 1900-65A-01-01-02-00-00 not appear as a Modbus node by default?
The final communications code of 1900-65A-01-01-02-00-00 is 00, which specifies no Modbus gateway option. Ethernet remains available for monitor configuration, but that is not the same as the optional Modbus client interface.
How are temperature inputs handled by 1900-65A-01-01-02-00-00?
Four temperature channels on 1900-65A-01-01-02-00-00 accept Type E, J, K or T thermocouples and 2- or 3-wire RTDs. The channel wiring and configured sensor type must agree before the value is used in protection logic.
Can the recorder outputs of 1900-65A-01-01-02-00-00 all carry the same variable type?
Each 4-20 mA recorder output on 1900-65A-01-01-02-00-00 can be assigned to a selected variable from any channel. The four outputs do not have to mirror one another, but their scales must match the receiving system.
What mounting dimensions matter for 1900-65A-01-01-02-00-00?
The attached-display and monitor combination of 1900-65A-01-01-02-00-00 is approximately 196.85 mm wide, 149.35 mm high and 97.79 mm deep. Bulkhead clearances must also allow access to the top and bottom terminal blocks.
Global Shipping Desk
Moore Automation
https://www.mvme.cn/Moore Automation coordinates secure packaging, carrier selection and shipment tracking for Bently Nevada 1900-65A-01-01-02-00-00. Fast dispatch and international destination support are organized around the complete option string so the product record remains attached to the shipment from packing through delivery.
More Model Options
| Control & Process | PLC & I/O | Monitoring & Network | Drives & Power |
|---|---|---|---|
| 01ABB AI562 | 16Allen-Bradley 1756-L85EP | 31Emerson KJ4002X1-CA1 | 46Honeywell CC-TDIL01 |
| 02Allen-Bradley 1756-L81EP | 17Emerson KJ4001X1-BE1 | 32Honeywell CC-TAIX11 | 47Yokogawa AVR10D |
| 03Emerson KJ2006X1-BK1 | 18Honeywell TC-FXX132 | 33Yokogawa ANR10S | 48Yokogawa ADV551 |
| 04Honeywell TC-CCR014 | 19Yokogawa ANB11S | 34Yokogawa ADV157 | 49GE IC600CB524 |
| 05Yokogawa ANB10S | 20Yokogawa ADV141 | 35GE IC600CB513 | 50ABB CI521-MODTCP |
| 06Yokogawa AAI835 | 21GE IC600CB504 | 36ABB CI511-ETHCAT | 51Allen-Bradley 1756-L902TS |
| 07GE IC600CP620 | 22ABB CI501-PNIO | 37Allen-Bradley 1756-L83ES | 52Emerson KJ1501X1-BB1 |
| 08ABB AO523 | 23Allen-Bradley 1756-L81ES | 38Emerson KJ1501X1-BC1 | 53Honeywell CC-TDOB01 |
| 09Allen-Bradley 1756-L83EP | 24Emerson KJ4002X1-BA1 | 39Honeywell CC-TAOX01 | 54Yokogawa EB401 |
| 10Emerson KJ4001X1-BA2 | 25Honeywell CC-TAIX01 | 40Yokogawa ANR10D | 55Yokogawa ADV557 |
| 11Honeywell TC-FXX102 | 26Yokogawa ANB11D | 41Yokogawa ADV161 | 56GE IC600CB525 |
| 12Yokogawa ANB10D | 27Yokogawa ADV142 | 42GE IC600CB516 | 57ABB CI522-MODTCP |
| 13Yokogawa ADV151 | 28GE IC600CB507 | 43ABB CI512-ETHCAT | 58Allen-Bradley 1756-L905TS |
| 14GE IC600CP630 | 29ABB CI502-PNIO | 44Allen-Bradley 1756-L84ES | 59Emerson KJ3001X1-BA1 |
| 15ABB AO561 | 30Allen-Bradley 1756-L82ES | 45Emerson KJ1501X1-BC2 | 60Honeywell CC-TCNT01 |









No related record found