Product Name B&R X67DM1321 X67 Digital Mixed I/O Module
Item NO. 2944221
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category B&R
Brand B&R
Creation Time 2026-11-22

B&R X67DM1321 X67 Digital Mixed I/O Module

B&R X67 System · Digital mixed I/O

B&R X67DM1321 X67 Digital Mixed I/O Module

Signal role and channel behavior

Product Overview

B&R X67DM1321 is an eight-channel digital mixed I/O module for the B&R X67 system. Mounted directly in an IP67 field installation, X67DM1321 connects digital sensors and actuators to the X2X Link network while allowing every channel to be assigned as an input or an output in software.

When a channel on X67DM1321 operates as an input, the signal enters through pin 4 of its M8 connector and passes through the configurable filter before the state is transferred with the network cycle. Positive edges can be latched, while two assigned counter channels can register event pulses or measure the interval between rising and falling edges.

For output operation, X67DM1321 drives the same connector through a current-sourcing stage and compares the commanded state with the monitored channel condition. The separate M8 supply connectors route 24 VDC through the station, and the module combines channel LEDs, supply monitoring, thermal shutdown and short-circuit reporting so signal faults and supply faults remain distinguishable.

Verified product data

Technical Information

Brand B&R
Model X67DM1321
Product Name X67 Digital Mixed I/O Module
Country Austria
System B&R X67
Digital Channels 8, configurable as inputs or outputs
Nominal Voltage 24 VDC
I/O Supply Range 18 to 30 VDC
Channel-to-Bus Isolation 500 Veff
Input Characteristic EN 61131-2 Type 1
Input Circuit Sink
Software Input Filter 0 to 25 ms, configurable
Additional Input Functions 50 kHz event counting and gate measurement
Event Counters 2, 16-bit
Digital Output Stage Current-sourcing FET
Nominal Output Current 0.5 A per channel
Total Nominal Output Current 4 A
Output Protection Thermal shutdown, short-circuit and inductive-load protection
X2X Link Connection M12, B-coded
I/O Connections 8 x M8, 3-pin
I/O Supply Connection M8, 4-pin
Degree of Protection IP67
Operating Temperature -25 to 60°C
Dimensions 53 x 85 x 42 mm
Weight 190 g
Signal assignment

Configuration and Programming

X67DM1321 uses channel masks, filter values and counter-mode registers to determine how physical signals become cyclic process data.

Channel direction mask

Each bit in the X67DM1321 I/O mask assigns one physical channel as an input or output. Output channels receive monitoring, while filtering applies only to channels operating as inputs.

Input filter and latch

Input filtering runs independently of the X2X Link cycle and suppresses pulses shorter than the configured delay. The positive-edge latch records short events with 200 µs resolution until the corresponding acknowledgment bit resets it.

Counter and gate modes

The two counter channels can record falling edges or measure the interval from a rising edge to a falling edge. Gate measurement uses one counter channel at a time and stores the result after the closing edge.

Channel and supply status

Diagnostics and Protection

X67DM1321 separates channel feedback, module state and power-supply limits so the control program can identify the affected layer.

Target-to-actual comparison

X67DM1321 compares each commanded output state with the monitored channel state. A short circuit or overload changes that channel status and sends an active error message instead of hiding the mismatch in one module-level flag.

Supply-limit monitoring

The I/O supply path is measured inside X67DM1321. Its status register separates a valid 18 to 30 V range from overvoltage or undervoltage, while voltage registers provide the measured input and output supply values.

Protected output path

The current-sourcing output stage combines thermal shutdown, short-circuit protection, reverse-polarity protection and inductive-load clamping. After an overload shutdown, the restart interval depends on the module temperature.

Installation and troubleshooting

Frequently Asked Questions

How should an X67DM1321 replacement be checked before installation?+
X67DM1321 should be matched by the complete material number, connector arrangement and channel requirement. Variants such as cable-equipped X67DM1321 versions should remain separate until their connection form and cable length have been confirmed.
Why does an X67DM1321 channel remain inactive after wiring?+
For X67DM1321, check the channel bit in the I/O mask first, because the same physical channel can be assigned as an input or an output. Then verify the M8 pin assignment, I/O supply status and the process value used by the controller.
What should be reviewed when an X67DM1321 input changes unexpectedly?+
Inspect the sensor signal and shared supply path for X67DM1321, then compare the configured filter with the pulse duration. A disturbance pulse shorter than the selected delay is suppressed, while the input latch can retain a positive edge until its channel is acknowledged.
Why does an X67DM1321 counter fail to increment?+
Confirm that X67DM1321 is using the counter function model and that the selected counter channel is assigned to its documented input. Event counting evaluates falling edges, so signal polarity, input direction and pulse frequency must all be checked together.
What does an X67DM1321 output diagnostic require the technician to inspect?+
When X67DM1321 reports an output error, disconnect the load safely and check for a short circuit, overload or inductive wiring issue. Compare the commanded state with the channel status and allow the thermally protected output stage to recover before retesting.
Which details are useful when requesting an X67DM1321?+
Provide the complete X67DM1321 model, quantity, label photo and required connector or cable scope. If the module uses counter or gate measurement, include that operating requirement so the channel configuration and related accessories remain clear.
Company information

Brand Supply Scope

Moore Automation

https://www.mvme.cn/

Moore Automation organizes multi-brand automation enquiries around exact manufacturer and model references. The requested module, connector scope and quantity remain visible from the first review through dispatch documentation.

Exact model recordBrand, model and suffix stay on one line item.
Accessory separationCables and connectors remain distinct from the module.
Document linkageAvailable technical files follow the confirmed identity.
Dispatch referencePacking details retain the reviewed model list.
Moore Automationhttps://www.mvme.cn/
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.