B&R X67 system · CAN and POWERLINK bus controllers
B&R X67BC7321 / X67BC8331 X67 Bus Controllers
Product Introduction
B&R X67BC7321 and X67BC8331 are IP67 bus controllers for the X67 system, each combining a fieldbus interface, an X2X Link station and eight configurable digital channels. X67BC7321 connects a CAN I/O fieldbus to X67 modules, while X67BC8331 operates as a POWERLINK controlled node.
On X67BC7321, the CAN controller, node setting and baud-rate setting determine how cyclic data reaches the integrated mixed-I/O channels and downstream X2X Link modules. On X67BC8331, 100BASE-TX POWERLINK frames enter through the D-coded M12 port, and the controller distributes process data to its local I/O and X2X Link branch with a 200 µs minimum cycle.
Both X67BC7321 and X67BC8331 use M8 connections for their eight sensor/actuator channels and separate supply routing for electronics and I/O power. The controllers differ in network connector, commissioning method and output capacity, so the complete model must be matched instead of treating the shared enclosure as proof of interchangeability.
Technical Information
| Brand | B&R |
|---|---|
| Model | X67BC7321 / X67BC8331 |
| Product Name | X67 Bus Controllers |
| System | B&R X67 |
| X67BC7321 Fieldbus | CAN I/O |
| X67BC8331 Fieldbus | POWERLINK 100BASE-TX |
| Integrated Channels | 8, configurable as inputs or outputs |
| X2X Link | M12, B-coded |
| Fieldbus Connector, X67BC7321 | M12, 5-pin CAN |
| Fieldbus Connector, X67BC8331 | M12, D-coded Ethernet |
| I/O Connections | 8 × M8, 3-pin |
| Supply Connections | 2 × M8, 4-pin |
| Nominal Supply | 24 VDC |
| Supply Range | 18 to 30 VDC |
| Input Characteristic | EN 61131-2 Type 1, sink |
| Software Input Filter | 0 to 25 ms |
| Output Current, X67BC7321 | 0.5 A per channel; 4 A total |
| Output Current, X67BC8331 | 2 A per channel; 8 A total |
| X67BC7321 CAN Distance | Up to 1000 m, baud-rate dependent |
| X67BC8331 Segment Length | Up to 100 m |
| POWERLINK Cycle, X67BC8331 | 200 µs minimum |
| Degree of Protection | IP67 |
| Operating Temperature | X67BC7321: 0 to 60°C; X67BC8331: -25 to 60°C |
| Dimensions | 53 × 85 × 42 mm |
| Approximate Weight | X67BC7321: 180 g; X67BC8331: 200 g |
Bus Controller Operation
Each controller terminates a different fieldbus and maps its cyclic data into the integrated I/O and X2X Link station.
X67BC7321 uses its CAN node and baud settings to enter the B&R CAN I/O network. A T-connector keeps the trunk continuous when the controller is exchanged.
X67BC8331 joins 100BASE-TX through its controlled-node interface. Topology and hub placement define how the node reaches the managing station.
Integrated channels and attached X67 modules share the controller data image, but their module identities and diagnostic registers remain distinct.
Integrated I/O and Expansion
The built-in mixed-I/O block handles local sensors and actuators while X2X Link extends the station to additional modules.
Each of eight M8 channels can be assigned as an input or output. The direction mask therefore must be restored before field wiring is energized.
X67BC7321 and X67BC8331 do not share the same per-channel or total output capacity, so a network change cannot be separated from load review.
The controller supplies limited X2X Link power. Additional modules and their consumption determine when a separate X67 system supply must be inserted.
Frequently Asked Questions
Can X67BC7321 replace X67BC8331 when the connector layout looks similar?+
Why does X67BC7321 remain offline after a controller exchange?+
What should be checked when X67BC8331 is visible but attached X67 modules are missing?+
How should the eight channels of X67BC7321 and X67BC8331 be commissioned?+
What can cause repeated output shutdown on X67BC7321 or X67BC8331?+
Which details belong in an X67BC7321 or X67BC8331 request?+
Brand Supply Scope
Moore Automation
https://www.mvme.cn/Moore Automation records automation products by manufacturer and complete model. The approach is useful when bus controllers, I/O modules and connection accessories share similar names but require different technical files and packing lines.