Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>B&R>B&R X20CM4810 / X20CM8281 X20 Multifunction Modules
B&R X20CM4810 / X20CM8281 X20 Multifunction Modules

B&R X20CM4810 / X20CM8281 X20 Multifunction Modules Item NO.: 2942574

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name B&R X20CM4810 / X20CM8281 X20 Multifunction Modules
Item NO. 2942574
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category B&R
Brand B&R
Creation Time 2026-11-19

B&R X20CM4810 / X20CM8281 X20 Multifunction Modules
CMX20 Module

SPECIAL FUNCTIONS / MEASUREMENT AND CONTROL

B&R X20CM4810 / X20CM8281 X20 Multifunction Modules

4 / MIXmeasurement functions
01

Product Introduction

B&R X20CM4810 and X20CM8281 are special-function modules for the B&R X20 I/O system with very different system responsibilities. X20CM4810 is a double-width, four-channel IEPE vibration measurement and analysis module, while X20CM8281 combines four digital inputs, two digital outputs, one universal analog input, one analog output and two counter functions in one standard-width module.

Each accelerometer channel of X20CM4810 can supply an IEPE sensor, digitize the signal at 24-bit resolution and calculate filtered time-domain, frequency-domain and condition values inside the module. Unlike the compact cyclic data of X20CM8281, X20CM4810 can transfer waveform or spectral buffers through Flatstream so the controller receives selected high-rate results without carrying every calculation in its normal process image.

The mixed terminal set of X20CM8281 routes sensors, actuators and analog signals through separate internal paths. Its digital inputs can feed event or gate-time counters, its digital outputs use monitored 24 VDC source stages, and its analog channels select voltage or current terminals; unlike X20CM4810, X20CM8281 is configured as a compact machine-I/O concentrator rather than a vibration-analysis engine.

02

Technical Information

Specification X20CM4810 X20CM8281
Brand B&R B&R
Product Name X20 Condition Monitoring Module X20 Mixed-Signal Multifunction Module
Country Austria Austria
Primary Role Vibration measurement and onboard analysis Combined digital, analog and counter I/O
Analog Inputs 4 IEPE acceleration channels 1 voltage / current input
Input Conversion 24 bit at 51.5625 kHz 12 bit analog input
Sensor Supply Individually switchable IEPE current source External sensor / loop supply
Digital Inputs None 4 x 24 VDC Type 1
Digital Outputs None 2 x 24 VDC source outputs
Analog Outputs None 1 voltage / current output
Counter Functions Condition parameters and frequency bands 2 event or gate-time counters, up to 20 kHz
Data Transfer Cyclic values and Flatstream buffers Standard process data and configuration registers
Mechanical Width Double-width module with X20BM31 Standard 12.5 mm module with X20BM11
Required Terminal X20TB12 X20TB12
Operating Temperature Derating and neighboring-module limits apply -25 to 60°C horizontal; -25 to 50°C vertical
Degree of Protection IP20 IP20
03

Internal Processing Roles

One module analyzes a high-rate signal stream; the other coordinates several independent I/O paths.

01

Onboard vibration analysis

X20CM4810 conditions each accelerometer signal with configurable high- and low-pass filters, envelope processing and Fourier analysis. Characteristic values and frequency bands are calculated in the module so the controller can supervise results without reproducing the full signal chain.

02

Mixed-I/O coordination

X20CM8281 places digital sensing, output actuation, analog measurement and analog command in one module. Each path has its own terminals and status, so commissioning proceeds by function rather than assuming the shared housing creates a common electrical circuit.

03

Counter relationship

The X20CM8281 counters use defined digital-input channels for event or gate measurement. X20CM4810 frequency analysis instead derives spectral information from sampled acceleration data; the two frequency concepts are not interchangeable.

04

Data Movement and System Load

The controller receives different quantities and different volumes of data from the two modules.

01

Flatstream transfer

X20CM4810 uses Flatstream to move buffered time- or frequency-domain data over X2X or POWERLINK in controlled blocks. Buffer handling, bus cycle and upload scheduling determine how much raw data reaches the controller.

02

Cyclic mixed process image

X20CM8281 exchanges compact digital, analog and counter values through the normal process image. Channel configuration determines how the analog paths and counters are interpreted without requiring a large waveform buffer.

03

Diagnostic prioritization

For X20CM4810, check sensor current, open-circuit status and buffer configuration before analyzing spectra. For X20CM8281, isolate the affected digital, analog or counter path and then follow that path from terminal to process data.

05

Frequently Asked Questions

When X20CM4810 reports an open sensor while X20CM8281 inputs remain normal, which circuits are being diagnosed?

X20CM4810 monitors IEPE sensor current on each acceleration channel; X20CM8281 digital inputs evaluate 24 VDC states, so their diagnostics describe different field circuits.

Which station parts differ between X20CM4810 and X20CM8281?

X20CM4810 is double-width and uses X20BM31 with X20TB12, while X20CM8281 uses X20BM11 with X20TB12; preserve the correct base module during replacement.

How should bus load be reviewed for X20CM4810 and X20CM8281?

For X20CM4810, review Flatstream buffer size, upload schedule and bus cycle; for X20CM8281, review the compact cyclic I/O and counter mapping.

What should be checked before firmware work on X20CM4810 or X20CM8281?

For X20CM4810 and X20CM8281, record the project, hardware variant and current configuration; X20CM4810 firmware updates can take minutes depending on bus cycle, so keep power stable until completion.

Why can an X20CM8281 counter miss events while X20CM4810 still reports frequency content?

X20CM8281 counters depend on pulse width, input channel and the 20 kHz event/gate configuration; X20CM4810 derives frequency information from sampled acceleration and follows different limits.

Can X20CM8281 replace X20CM4810 for vibration analysis?

No. X20CM4810 supplies IEPE sensors and performs high-rate vibration analysis, while X20CM8281 provides mixed standard I/O and counters without the X20CM4810 signal-processing engine.

06

After-Sales Follow-Up

Moore Automation

https://www.mvme.cn

Moore Automation keeps delivery evidence, received-item questions and agreed follow-up actions under the original order reference.

Delivery confirmationCourier, tracking and receipt information identify the shipment being discussed.
Received-item recordPackaging, labels and included items are recorded before the issue is assessed.
Issue descriptionCustomer observations and supporting images are kept with the affected order line.
Resolution trailAgreed actions and later updates remain visible as the follow-up progresses.

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.