B&R X20DI4760 X20 NAMUR Digital Input Module

B&R X20DI4760 X20 NAMUR Digital Input Module Item NO.: 2940467

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name B&R X20DI4760 X20 NAMUR Digital Input Module
Item NO. 2940467
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category B&R
Brand B&R
Creation Time 2026-11-18

B&R X20DI4760 X20 NAMUR Digital Input Module
B&R X20 System

B&R X20DI4760X20 NAMUR Digital Input Module

4 NAMUR inputsOpen-line diagnosticsShort-circuit diagnostics4 event counters
Configuration snapshot
Input quantity4
Sensor interfaceNAMUR encoder per EN 60947-5-6
Event counters4 cyclic counters
01

Product Details

B&R X20DI4760 is a four-channel NAMUR digital input module for the B&R X20 control system. X20DI4760 receives current signals from EN 60947-5-6 sensors, converts each channel into process data and supplies a cyclic event count for every input to the controller over the X20 bus.

When inputs on X20DI4760 change state, each positive edge advances the cyclic 8-bit counter assigned to that channel. The maximum pulse rate and input delay depend on how many channels are active at the same time, so the controller must interpret the count together with the current channel load instead of applying the single-channel timing to all four inputs.

Each X20DI4760 field loop is connected through its own Kx+ and Kx− terminals and is checked for open-circuit and short-circuit current. Channel indicators and software status separate a process transition from a line fault, while the complete four-channel input group remains electrically isolated from the X20 bus.

02

Specifications Overview

Specification X20DI4760
Product type NAMUR digital input module
Input quantity 4
Sensor interface NAMUR encoder per EN 60947-5-6
Event counters 4 cyclic counters
Counter evaluation Each positive edge
Counter size 8-bit
Maximum input frequency 1600 / 1100 / 870 / 680 Hz for 1 / 2 / 3 / 4 active inputs
Open-circuit detection Below 350 µA
Short-circuit detection Above 7 mA
Open-circuit voltage 8.05 V ±0.33%
Switching-amplifier resistance 1 kΩ ±1%
Maximum short-circuit current 8.2 mA
Input delay ≤310 / 450 / 570 / 735 µs for 1 / 2 / 3 / 4 active inputs
Switching range 1.2 to 2.1 mA; typical hysteresis 300 µA
Bus / internal I/O power 0.01 W / 1.5 W
Isolation 500 Veff between channel group and bus
Temperature −25 to 60°C horizontal; −25 to 50°C vertical
Protection IP20
Required accessories X20BM11 and X20TB12 ordered separately
Pitch 12.5 +0.2 mm
03

Diagnostics and Protection

X20DI4760 evaluates the NAMUR process state and the electrical condition of each field loop separately, so a wiring fault does not have to be inferred from the application bit alone.

01

Process state versus line state

The green indication follows the evaluated input state, while the red channel indication reports an open or shorted loop. Reading both states together distinguishes a sensor transition from a conductor or loop-current fault.

02

Channel-level fault location

Open-circuit and short-circuit diagnostics are available per channel through indication and software. If only one red channel state is active while the module remains in RUN, troubleshooting can stay on that Kx+ and Kx− pair.

03

Module-level separation

Run/error information identifies supply, operating-mode or firmware conditions that affect the module as a whole. Comparing module status with the four line-state results prevents a common station fault from being treated as four independent sensor failures.

04

Programming

X20DI4760 exposes cyclic edge counters whose timing changes with the number of active inputs, requiring the application to interpret raw counts together with channel activity and line diagnostics.

01

Cyclic value handling

Each counter returns a repeating byte value rather than an unlimited production total. The program must recognize wraparound when it needs a value wider than the native counter and must preserve the relationship between the counter and its input channel.

02

Active-channel timing context

Counter input timing is shared across the module, so enabling additional active inputs changes the pulse rate that can be evaluated. A count discrepancy should be compared with the current number of active channels rather than with the single-channel case.

03

Valid pulses require a healthy loop

A positive edge is useful only when the NAMUR loop is electrically valid. The application can combine the count value with open-line and short-circuit status so a wiring fault is not silently interpreted as a stopped process.

05

Product Q&A

01FAQ

Why does X20DI4760 report an open circuit while the sensor is installed?

X20DI4760 flags an open line below 350 µA; check the NAMUR sensor type, Kx+ and Kx− polarity, terminal continuity and field current before changing application logic.

02FAQ

Why does X20DI4760 count correctly on one channel but miss pulses with four channels active?

X20DI4760 maximum frequency falls from 1600 Hz with one active input to 680 Hz with four, while input delay rises, so validate pulse duration against the active-channel condition.

03FAQ

How should X20DI4760 eight-bit counter rollover be handled?

The X20DI4760 controller program should read each cyclic 8-bit value frequently, detect wraparound and maintain a wider accumulated total whenever more than 255 events must be retained.

04FAQ

Can a standard 24 VDC proximity switch be wired directly to X20DI4760?

X20DI4760 is designed for NAMUR encoders per EN 60947-5-6; verify the sensor output and loop-current behavior instead of assuming compatibility from voltage or connector style alone.

05FAQ

What does an X20DI4760 red channel LED indicate?

On X20DI4760, a blinking red channel indication identifies an open line and a steady red indication identifies a short circuit; compare it with measured loop current and software diagnostics.

06FAQ

What should be checked when all X20DI4760 channels fail at the same time?

When every X20DI4760 channel changes together, check module supply, X20 bus seating and run/error status before opening four separate NAMUR loops; channel LEDs then identify any remaining field-specific fault.

06

Customer Support

Moore Automation

https://www.mvme.cn/

Moore Automation uses a named sales contact to keep questions, model evidence and commercial updates in one conversation. Clarifications are recorded before the request moves to order handling.

Named sales contact
Consolidated questions
Recorded clarifications
Direct follow-up
CONTACT 01

Initial review

The complete model and the buyer’s requested condition are checked first.

CONTACT 02

Clarification

Missing revision, photo, quantity or destination details are requested together.

CONTACT 03

Order handover

Confirmed information moves forward without changing the recorded item identity.

Enquiry DetailsMoore Automation

CompanyMoore Automation
ManagerLeonia

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.