Product Name B&R X20CP0483 / X20CP0482 X20 Compact-S PLCs
Item NO. 2940466
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category B&R
Brand B&R
Creation Time 2026-11-18

B&R X20CP0483 / X20CP0482 X20 Compact-S PLCs
B&R X20 System

B&R X20CP0483 / X20CP0482X20 Compact-S PLCs

Compact-S controller1 GB eMMCBase-dependent expansionOrientation derating
Configuration snapshot
ProcessorARM Cortex-A9
Clock frequency500 MHz / 300 MHz
Working memory256 MB DDR3 SDRAM / 128 MB DDR3 SDRAM
01

Model Overview

B&R X20CP0483 and X20CP0482 are X20 Compact-S PLCs for the B&R X20 control system. X20CP0483 and X20CP0482 run the control application, manage the local X2X I/O modules and connect the station to Ethernet and POWERLINK networks.

Processing and memory capacity distinguish X20CP0483 from X20CP0482. X20CP0483 uses a 500 MHz processor with 256 MB DDR3 working memory and 32 kB FRAM, whereas X20CP0482 uses a 300 MHz processor with 128 MB DDR3 and 16 kB FRAM; both controllers store the runtime and project on 1 GB eMMC.

The permitted station arrangement for X20CP0483 and X20CP0482 depends on mounting direction, ambient temperature and the current supplied to the attached I/O. Horizontal and vertical installation use different derating limits, and the selected X20BB base plus the separate power module determine the interface positions and the electrical path into the Compact-S assembly.

02

Technical Details

Specification X20CP0483 X20CP0482
Product type X20 Compact-S PLC X20 Compact-S PLC
Processor ARM Cortex-A9 ARM Cortex-A9
Clock frequency 500 MHz 300 MHz
Working memory 256 MB DDR3 SDRAM 128 MB DDR3 SDRAM
Remanent memory 32 kB FRAM 16 kB FRAM
Application memory 1 GB eMMC 1 GB eMMC
Shortest task class 0.8 ms 1 ms
Typical instruction cycle 0.0145 µs 0.0247 µs
Power consumption 2.9 W 2.7 W
Interface slots by base 0 / 1 / 2 with X20BB5x / 6x / 7x 0 / 1 / 2 with X20BB5x / 6x / 7x
Ethernet 10/100 Mbit/s 10/100 Mbit/s
POWERLINK V2, 100 Mbit/s V2, 100 Mbit/s
USB 2 × Type A, 0.2 A each 2 × Type A, 0.2 A each
X2X Link Master Master
Horizontal operation −25 to 60°C with specified derating above 50°C −25 to 60°C with specified derating above 50°C
Vertical operation −25 to 50°C with specified derating above 40°C −25 to 50°C with specified derating above 40°C
Required assembly Base, power module and X20TB12 separate Base, power module and X20TB12 separate
Protection IP20 IP20
03

Operating Characteristics

X20CP0483 and X20CP0482 scale execution capacity, working memory and retained-data space together, so project behavior must be evaluated as a complete resource profile.

01

Task-load comparison

The higher controller tier gives the scheduler more execution margin, while the lower tier requires the verified task set to remain within its timing budget. Online task statistics and peak cycle behavior provide the relevant comparison during migration.

02

Live data and retained data

Working memory supports live program operation, whereas FRAM holds variables selected for retention. A project can fit in application storage yet still exceed its runtime or remanent-data allocation, so each resource is checked independently.

03

Project portability limits

Shared network connections do not make the controller targets identical. Automation Runtime support, compiled hardware configuration, task timing and actual memory use all need validation before the same source project is deployed to the other model.

04

Installation

The Compact-S derating relationship combines mounting orientation, I/O supply load and free space beside the controller; changing any one of them changes the permitted station arrangement.

01

Orientation establishes the thermal case

Horizontal and vertical mounting use different derating curves. The cabinet review begins with the actual orientation because the available I/O supply current and the temperature at which spacing is required are derived from that case.

02

Spacing follows the load condition

The specified dummy-module position creates separation from an adjacent heat source when the derating condition applies. It is part of the thermal arrangement, not an unused placeholder that can be removed without checking load and temperature.

03

Base and power module remain linked

The selected base controls interface positions, while the separate power module supplies the station. Their order numbers, wiring and connected I/O load must remain consistent when the controller body is exchanged.

05

Customer Questions

01FAQ

How should X20CP0483 and X20CP0482 be chosen for an existing project?

Compare the verified task load, DDR3 use and required remanent variables: X20CP0483 provides the higher 500 MHz/256 MB tier, while X20CP0482 provides 300 MHz/128 MB.

02FAQ

Can X20CP0483 and X20CP0482 exchange the same project unchanged?

X20CP0483 and X20CP0482 share architecture, but task timing, memory consumption, Automation Runtime and base configuration must be validated before treating the project as interchangeable.

03FAQ

What does the derating diagram require for X20CP0483 and X20CP0482?

For X20CP0483 and X20CP0482 above the orientation threshold, reduce I/O supply current and install the specified dummy-module spacing; both derating measures apply together.

04FAQ

Why can X20CP0483 and X20CP0482 start without the expected serial port?

The RS232, RS485 or CAN option for X20CP0483 and X20CP0482 comes from the selected Compact-S base, so a different base can change available connections even when the CPU is correct.

05FAQ

What should be recorded before replacing X20CP0483 or X20CP0482?

Record the exact X20CP0483 or X20CP0482 order number, base type, power-module type, terminal wiring, network addresses, runtime version and current project archive.

06FAQ

Why can X20CP0483 and X20CP0482 boot successfully but lose expected retained values?

X20CP0483 and X20CP0482 can load the application from eMMC while FRAM retention still depends on the project variable declaration and the correct controller target; compare the remanent configuration before replacing hardware.

06

Service Support

Moore Automation

https://www.mvme.cn/

Moore Automation supports the commercial review of automation spares by checking the supplied model evidence, clarifying requested condition and keeping documentation requirements with the enquiry.

Nameplate review
Condition clarification
Document requests
Order coordination
SUPPORT 01

Model confirmation

Photos, labels and suffixes are compared with the submitted part number.

SUPPORT 02

Requirement clarification

Condition, quantity, destination and requested documentation are recorded.

SUPPORT 03

Response alignment