Dedicated safety task
Safety routines run in their assigned task and use safety-tag rules rather than sharing unrestricted data paths with standard logic.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Allen-Bradley 5069-L306ERMS2 / 5069-L320ERMS2 Compact GuardLogix 5380 SIL 2 Controllers |
| Item NO. | 2928065 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | ALLEN-BRADLEY |
| Brand | ALLEN-BRADLEY |
| Creation Time | 2026-10-29 |
Allen-Bradley 5069-L306ERMS2 / 5069-L320ERMS2 are Compact GuardLogix 5380 SIL 2 controllers that execute standard machine logic and a separately managed safety task in one platform. Standard I/O, safety I/O and integrated motion reach the controller through the local 5069 bus or its embedded EtherNet/IP interfaces.
A dedicated safety task on Allen-Bradley 5069-L306ERMS2 / 5069-L320ERMS2 isolates safety-program execution from the remaining thirty-one standard tasks. Safety memory is paired with standard memory, while safety signatures and locked project access help maintain the validated safety application after commissioning.
Resource scale separates Allen-Bradley 5069-L306ERMS2 / 5069-L320ERMS2. The L306ERMS2 supports sixteen network nodes, two position-loop axes and eight local modules; the L320ERMS2 raises those limits to forty nodes, eight axes and thirty-one local modules for a larger safeguarded machine cell.
| Technical item | 5069-L306ERMS2 | 5069-L320ERMS2 |
|---|---|---|
| Brand | Allen-Bradley | |
| Product Name | Compact GuardLogix 5380 SIL 2 Controller | |
| Country | United States | |
| Standard Memory | 0.6 MB | 2 MB |
| Safety Memory | 0.3 MB | 1 MB |
| EtherNet/IP Nodes | 16 | 40 |
| Position-Loop Axes | 2 | 8 |
| Local 5069 I/O Modules | 8 maximum | 31 maximum |
| Tasks | 31 standard + 1 safety | |
| Ethernet Ports | 2 × 10/100/1000 Mbps | |
| Network Modes | Dual-IP or Linear/DLR | |
| Module Power Input | 18–32 V DC | |
| Power Dissipation | 9 W | |
| Mounting | Horizontal DIN rail | |
| Dimensions | 143.97 × 98.10 × 136.81 mm | |
| Weight | Approx. 0.768 kg | |
Allen-Bradley 5069-L306ERMS2 / 5069-L320ERMS2 keep safety logic, safety memory and project validation separate from ordinary controller execution.
Safety routines run in their assigned task and use safety-tag rules rather than sharing unrestricted data paths with standard logic.
A validated safety signature identifies the compiled safety application; later edits require the safety portion to be unlocked and validated again.
Controller security and safety locking restrict who can alter safety routines, signatures and safety I/O relationships after commissioning.
Status indicators and controller diagnostics distinguish power, run, fault and force conditions before the application is opened.
Safety I/O connection state and diagnostic codes identify whether the problem belongs to a field device, network path or safety configuration.
A fault is cleared only after the cause is removed and the safety task returns through the configured restart sequence; bypassing a failed safety path is not treated as recovery.
On Allen-Bradley 5069-L306ERMS2 / 5069-L320ERMS2, check controller security, safety lock state, project ownership and whether the safety application is currently signature-protected.
Choose Allen-Bradley 5069-L306ERMS2 / 5069-L320ERMS2 from standard and safety memory, network nodes, local I/O modules and required motion axes.
Allen-Bradley 5069-L306ERMS2 / 5069-L320ERMS2 use controlled safety-data exchanges; standard code cannot be treated as an unrestricted writer to safety-owned data.
For Allen-Bradley 5069-L306ERMS2 / 5069-L320ERMS2, verify controller identity, firmware, safety signature, safety I/O ownership and the documented restart behavior before operation.
A link on Allen-Bradley 5069-L306ERMS2 / 5069-L320ERMS2 confirms Ethernet continuity, not the validity of the safety connection, device configuration or application signature.
Before servicing Allen-Bradley 5069-L306ERMS2 / 5069-L320ERMS2, isolate controller module power and every field-power source feeding local or remote safety I/O, then verify the de-energized state.
Moore Automation keeps the full manufacturer, model, quantity and destination linked to the same customer enquiry. Supporting photographs and available documentation can be reviewed with the product record when clarification is required.
Share the full model, revision and requested quantity for review.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found