Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>AB>Allen-Bradley 22F-D6P0N103 / 22F-D8P7N103 PowerFlex 4M AC Drives
Allen-Bradley 22F-D6P0N103 / 22F-D8P7N103 PowerFlex 4M AC Drives

Allen-Bradley 22F-D6P0N103 / 22F-D8P7N103 PowerFlex 4M AC Drives Item NO.: 2909799

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Allen-Bradley 22F-D6P0N103 / 22F-D8P7N103 PowerFlex 4M AC Drives
Item NO. 2909799
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category AB
Brand ALLEN-BRADLEY
Creation Time 2026-09-20

Allen-Bradley 22F-D6P0N103 / 22F-D8P7N103 PowerFlex 4M AC Drives

COMPACT DRIVE SELECTION · 3 HP AND 5 HP

Allen-Bradley 22F-D6P0N103 / 22F-D8P7N103 PowerFlex 4M AC Drives

Higher-current PowerFlex 4M choices for 480 V-class machinery.

HIGHER OUTPUT22F
POWERFLEX 4M

Drive Selection Summary

Allen-Bradley 22F-D6P0N103 and 22F-D8P7N103 are PowerFlex 4M adjustable-frequency AC drives for a 380–480 V AC three-phase input. Both provide a 0–460 V three-phase output in the PowerFlex 4M platform.

The 22F-D6P0N103 carries a 2.2 kW (3 HP), 6.0 A output rating, while the 22F-D8P7N103 carries a 3.7 kW (5 HP), 8.7 A output rating. Their rated input currents are 5.2 A and 7.0 A, with maximum input values of 6.2 A and 8.3 A.

Both 22F-D6P0N103 and 22F-D8P7N103 use Frame B, an IP20 open enclosure, an LED display and a fixed digital keypad. The two catalog configurations omit the CE-compliant filter and brake IGBT and have a 50–60 Hz frequency rating.

VERIFIED OPERATING VALUES

Operating Specifications

Technical Item 22F-D6P0N103 22F-D8P7N103
Brand Allen-Bradley Allen-Bradley
Product Type PowerFlex 4M AC drive PowerFlex 4M AC drive
Brand Country United States United States
Input Voltage 380–480 V AC, three phase 380–480 V AC, three phase
Output Voltage 0–460 V AC, three phase 0–460 V AC, three phase
Motor Rating 2.2 kW / 3 HP 3.7 kW / 5 HP
Continuous Output Current 6.0 A 8.7 A
Rated Input Current 5.2 A 7.0 A
Maximum Input Current 6.2 A 8.3 A
Recommended Branch Protection 10 A class 15 A class
Enclosure Rating IP20 / NEMA open type IP20 / NEMA open type
Local Operator Interface Integral keypad and potentiometer Integral keypad and potentiometer
Serial Interface RS-485 / DSI RS-485 / DSI
Frame Size B B
EMC Filter No CE-compliant filter No CE-compliant filter
Brake IGBT Omitted Omitted
DIAGNOSTICS AND PROTECTION

Motor and Drive Protection

Motor overload

22F-D6P0N103 and 22F-D8P7N103 provide I²t Class 10 motor protection at 150% for 60 seconds or 200% for 3 seconds.

Overcurrent response

The protection data specifies a 200% hardware current limit and a 300% instantaneous-fault level.

DC-bus limits

For the 380-480 V class, overvoltage trips at an 810 V DC bus and undervoltage trips at a 390 V DC bus.

CONFIGURATION AND PROGRAMMING

Stop Modes and Ramp Configuration

The PowerFlex 4M platform provides several programmed stopping profiles.22F-D6P0N103 / 22F-D8P7N103

22F-D6P0N103 and 22F-D8P7N103 support Ramp, Coast, DC-Brake, Ramp-to-Hold and S-curve stop modes.

  • Two acceleration times and two deceleration times can be programmed independently.
  • Each acceleration or deceleration time is adjustable from 0 to 600 seconds in 0.1-second increments.
  • Control ride-through is at least 0.5 seconds with a typical value of 2 seconds; faultless power ride-through is 100 ms.
FIELD QUESTIONS

Commissioning FAQs

When is 22F-D6P0N103 / 22F-D8P7N103 the better rating choice for a 3 HP or 5 HP motor?+

Match the continuous motor current and load duty first: the two drives provide 6.0 A and 8.7 A respectively. Confirm overload and ambient derating before ordering.

How do 22F-D6P0N103 / 22F-D8P7N103 differ in branch-circuit planning?+

Their manual protection classes differ, commonly 10 A versus 15 A. The final fuse or circuit breaker must come from the approved table and installation code.

Why should deceleration be reviewed for 22F-D6P0N103 / 22F-D8P7N103?+

A high-inertia load can regenerate energy into the DC bus during stopping. If the stop is too aggressive, an overvoltage trip may occur and a braking solution may be required.

Can 22F-D6P0N103 / 22F-D8P7N103 run in a sealed cabinet without a heat calculation?+

No. Losses accumulate inside the cabinet, so the actual ambient, enclosure size and cooling method must be checked before operation.

What should be inspected after an overload trip on 22F-D6P0N103 / 22F-D8P7N103?+

Check the driven machine, acceleration profile, motor current, parameter values and airflow before resetting. Repeated resetting can hide a mechanical or sizing problem.

How should grounding be arranged for 22F-D6P0N103 / 22F-D8P7N103?+

Use a short protective-earth path, bond the panel correctly and follow the manual shield guidance. Do not use the control cable shield as the protective conductor.

MOORE AUTOMATION

Customer Support

Customer Support

One contact from rating check to shipment

Moore Automation keeps technical and commercial questions together so the ordered catalog number remains clear.

Model reviewQuotation follow-upPacking photosShipment updates
www.mvme.cn

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.