Overload class
Normal duty and heavy duty reserve different overload capability, so the driven machine's load profile selects the correct column.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Allen-Bradley 20G11ND034JA0NNNNN / 20G11ND065JA0NNNNN PowerFlex 755 480 V AC Drives |
| Item NO. | 2911578 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | AB |
| Brand | ALLEN-BRADLEY |
| Creation Time | 2026-09-28 |
Across medium-power 480 V motor applications, Allen-Bradley 20G11ND034JA0NNNNN and 20G11ND065JA0NNNNN are PowerFlex 755 AC drives with embedded EtherNet/IP. They occupy the motor feeder between the three-phase source and motor, using the power section to regulate speed and torque while the embedded network interface exchanges commands, references, feedback and drive status with a controller.
The internal route through 20G11ND034JA0NNNNN and 20G11ND065JA0NNNNN runs from AC input to the DC link and inverter, with DC terminals and a DB transistor available for the defined external power connections. Both are filtered, forced-air open-type drives without a supplied HIM, but the 34 A unit uses Frame 3 and the 65 A unit uses Frame 4, changing panel space and frame-specific hardware.
| Technical Item | 20G11ND034JA0NNNNN | 20G11ND065JA0NNNNN |
|---|---|---|
| Brand | Allen-Bradley | |
| Product Type | PowerFlex 755 AC Drive, with Embedded Ethernet/IP | |
| Brand Country | United States | |
| Corrosive Gas Protection and Cooling Type | Standard Protection, Forced Air | |
| Voltage Class | 480 VAC, 3 PH | |
| Output Current | 34 Amps, 25HP ND, 20HP HD | 65 Amps, 50HP ND, 40HP HD |
| Enclosure Type | IP20/IP00, NEMA/UL Open Type | |
| Input Type | AC Input with DC Terminals | |
| Frame Size | Frame 3 | Frame 4 |
| EMC Filtering Options | Filtered, CM jumper installed (preferred) | |
| Dynamic Braking | DB Transistor | |
| HIM | Blank (No HIM) | |
| Maximum Surrounding Air Temperature | 0...50 °C (32...122 °F) | |
| Storage Temperature | -40...70 °C (-40...158 °F) | |
| Relative Humidity | 5...95%, noncondensing | |
| Input Frequency Tolerance | 47...63 Hz | |
| Displacement Power Factor | 0.98 across the speed range | |
| Efficiency | 97.5% at rated current and nominal line voltage | |
| Output Voltage Range | 0 to rated motor voltage | |
| Output Frequency Range | 0...325 Hz at 2 kHz carrier; 0...590 Hz at 4 kHz carrier | |
| Maximum Short-Circuit Rating | 200,000 A RMS symmetrical | |
| Operating Shock | 15 g peak for 11 ms | |
| Operating Vibration | 1.000 mm displacement, 1.5 g peak | |
Motor load behavior determines which published power rating can be applied.
Normal duty and heavy duty reserve different overload capability, so the driven machine's load profile selects the correct column.
The 34 A and 65 A power sections serve different feeder sizes even when their EtherNet/IP functions are configured identically.
Voltage class, current and duty rating are checked together before the drive is assigned to a motor.
Moving between the two output classes also changes the physical drive platform.
Frame 3 and Frame 4 have different widths, mounting points and service-component selections.
The line, motor, DC and control conductors must approach the correct terminal zones without blocking forced-air cooling.
The enclosure must preserve access to the power terminals, control area and cooling components after neighboring devices are fitted.
Not without mechanical modification. 20G11ND034JA0NNNNN uses Frame 3 and 20G11ND065JA0NNNNN uses Frame 4, so the outline, mounting points and airflow reservation differ.
Each drive has separate normal-duty and heavy-duty ratings. Motor current and the required overload profile determine which duty value applies.
No. Embedded EtherNet/IP carries configured commands, references and returned status; three-phase input and controlled motor output remain on dedicated power terminals.
No. They belong to the drive DC-link power architecture. Network and control wiring use their designated interfaces and remain separate from the DC power path.
50 °C is the published maximum for these Frame 3 and Frame 4 open drives. The specified mounting clearances and forced-air path must be maintained at that limit.
A Moore Automation enquiry is handled through one sales contact who coordinates product references, commercial questions and order progress. The company also supports fast quotation, careful packing, international carrier options and tracking after dispatch.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.