Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>AB>Allen-Bradley 1772-ME PLC-2 Segmented CMOS RAM Memory Module
Allen-Bradley 1772-ME PLC-2 Segmented CMOS RAM Memory Module

Allen-Bradley 1772-ME PLC-2 Segmented CMOS RAM Memory Module Item NO.: 2909169

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Allen-Bradley 1772-ME PLC-2 Segmented CMOS RAM Memory Module
Item NO. 2909169
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category AB
Brand ALLEN-BRADLEY
Creation Time 2026-09-17

Allen-Bradley 1772-ME PLC-2 Segmented CMOS RAM Memory Module
CATALOG1772ME

Allen-Bradley · PLC-2 Memory

Allen-Bradley 1772-ME PLC-2 Segmented CMOS RAM Memory Module

Segmented CMOS RAM storage for PLC-2 user programs, data tables, I/O images and message areas.

Product identity and system role

Product Overview

Designed for modular PLC-2 memory expansion, the 1772-ME is a segmented CMOS RAM module whose installed memory segments determine the available capacity.

The 1772-ME stores the user program together with data-table words, input and output image information and message-area data used by the controller.

Parity checking helps the PLC-2 identify a memory error, while the module occupies one slot in the 1772-LA processor chassis and must be handled as a system memory component rather than a general-purpose card.

Concise verified values

Technical Data

Technical Item 1772-ME
Brand Allen-Bradley
Product Type Segmented CMOS RAM Memory Module
Brand Country United States
Controller Family PLC-2
Memory Architecture Segmented CMOS RAM
Stored Information Program, data table, I/O image, message area
Error Detection Parity checking
Processor Chassis 1772-LA
Chassis Space 1 slot
Segment-selected capacity

Memory Expansion Architecture

Functional focus

Base module

The 1772-ME provides the PLC-2 memory-module structure and accepts the memory arrangement used to establish capacity.

System relationship

Controller storage

Program instructions and operating data share the installed memory resource within the application layout.

Maintenance check

Expansion decision

Capacity planning must consider both program growth and the words reserved for data and messages.

Separate the stored areas

Program & Data Retention

Memory serves several jobs.The module holds control logic as well as the data table, I/O image and message area, so usable program space is not the only sizing concern.

For 1772-ME, program & data retention must be reviewed with the installed controller hardware and saved application rather than treated as an isolated catalog-number change.

  • Account for the data table before estimating free space.
  • Preserve the I/O image requirements of the application.
  • Treat a parity indication as a memory-integrity fault.
Selection, replacement and commissioning

Practical Questions

Why can a 1772-ME installation show less free program space than its nominal memory arrangement suggests?

The same memory resource also carries data-table words, I/O image information and message data. Review those allocations before deciding that the module itself has lost capacity.

Can 1772-ME be treated as a self-contained fixed-capacity module?

It is the segmented CMOS RAM member of the family, so capacity depends on the installed memory-segment arrangement. A fixed-capacity replacement should not be assumed from the ME prefix alone.

What does a parity fault mean for 1772-ME?

Parity checking is used to detect a memory-data error. Protect the running process, preserve available program information and investigate the module and its installation before returning the controller to service.

Which information should be backed up before replacing 1772-ME?

Back up the user program and the configuration that defines the data table, I/O image and message requirements. The replacement must be prepared for all of those stored areas, not only the ladder logic.

Where is 1772-ME installed in the PLC-2 hardware?

The module occupies one slot in the 1772-LA processor chassis. Power should be removed and the controller procedure followed before inserting or removing memory hardware.

How should a buyer specify 1772-ME when several PLC-2 memory types are present?

Provide the full 1772-ME catalog and the required memory-segment configuration. Do not shorten the request to a generic PLC-2 memory module because fixed-capacity core modules are different products.

Moore Automation

Global Sourcing Service

Moore Automation

One enquiry reaches a broad automation network

Moore Automation supports industrial buyers across PLC, DCS, TSI, HMI, drive, sensor and control-system product ranges. The sourcing team searches established channels for both routine and scarce items.

Commercial communication remains tied to the requested model and quantity, reducing the risk of a near-match being quoted in place of the required catalog.

Wide brand scopeMultiple automation families.
Exact model focusFull suffixes are retained.
Fast responsePrompt commercial review.
Worldwide deliveryInternational carrier options.

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.