Three selector inputs
SW1, SW2, and SW3 on 160-BA01NPS1 / 160-AA02NPS1 create the binary combinations used for the eight presets.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Allen-Bradley 160-BA01NPS1 / 160-AA02NPS1 preset-speed drives |
| Item NO. | 2915750 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | AB |
| Brand | ALLEN-BRADLEY |
| Creation Time | 2026-10-10 |
Allen-Bradley 160-BA01NPS1 / 160-AA02NPS1 are Bulletin 160 SSC variable speed drives with the Preset Speed control option. Each drive converts a three-phase mains input into variable-frequency, three-phase motor output for a 0.37 kW motor, while the BA01 and AA02 power sections serve different incoming voltage classes.
Preset commands enter 160-BA01NPS1 / 160-AA02NPS1 through SW1, SW2, and SW3 at terminal block TB3. Dry contacts or open-collector devices switch these inputs against the internal 12 V control supply, and the three-input combination selects one of the eight frequencies stored in parameters 61 through 68.
Although their motor rating is common, 160-BA01NPS1 / 160-AA02NPS1 connect to different supplies. The BA01 power stage accepts the 380-460 V class, while the AA02 power stage accepts the 200-240 V class; each stage then produces the current associated with its own voltage class rather than sharing one interchangeable mains connection.
| Technical Item | 160-BA01NPS1 | 160-AA02NPS1 |
|---|---|---|
| Brand | Allen-Bradley | |
| Product Family | Bulletin 160 SSC | |
| Product Type | Preset-speed variable speed drive | |
| Input Supply | 380-460 V AC, three-phase, 50/60 Hz | 200-240 V AC, three-phase, 50/60 Hz |
| Operational Input Range | 340-506 V AC | 180-265 V AC |
| Motor Rating | 0.37 kW (0.5 hp) | |
| Maximum Output Current | 1.2 A | 2.3 A |
| Input Current | 1.4 A at nominal 460 V | 2.8 A at nominal 230 V |
| Input kVA | 1.1 kVA | |
| Power Dissipation | 25 W | 20 W |
| Cooling Method | Convection cooled | |
| Enclosure | N - IP20 open style | |
| Control Version | PS1 - Preset Speed | |
| Preset Frequencies | Eight | |
| Preset Inputs | SW1, SW2, and SW3 at TB3 | |
| Input Device | Dry contact or open-collector input | |
| Control Supply | Internal 12 V | |
| Programming Access | Program Keypad Module | |
| Maximum Output Frequency | 240 Hz | |
| Drive Dimensions | 152 x 80 x 165 mm | |
The PS1 control in 160-BA01NPS1 / 160-AA02NPS1 converts three discrete selector inputs into eight stored output-frequency choices.
SW1, SW2, and SW3 on 160-BA01NPS1 / 160-AA02NPS1 create the binary combinations used for the eight presets.
Parameters 61–68 hold the preset frequencies used by 160-BA01NPS1 / 160-AA02NPS1.
A Program Keypad Module is required when the factory preset values in 160-BA01NPS1 / 160-AA02NPS1 must be changed.
The common 0.37 kW rating in 160-BA01NPS1 / 160-AA02NPS1 is delivered from two different three-phase supply classes.
The BA01 member of 160-BA01NPS1 / 160-AA02NPS1 uses 380–460 V AC and a 1.2 A output rating.
The AA02 member of 160-BA01NPS1 / 160-AA02NPS1 uses 200–240 V AC and a 2.3 A output rating.
Both 160-BA01NPS1 / 160-AA02NPS1 convert their respective mains input into variable-frequency three-phase motor output.
The BA01 member of 160-BA01NPS1 / 160-AA02NPS1 requires 380–460 V three-phase input, while AA02 requires 200–240 V three-phase input. Their shared horsepower does not override this supply difference.
Dry contacts or open-collector devices switch SW1, SW2, and SW3 at TB3 on 160-BA01NPS1 / 160-AA02NPS1. The three-input combination selects one of the eight stored preset-frequency parameters.
The stored parameter values in 160-BA01NPS1 / 160-AA02NPS1 may not match the commissioned drive. Compare parameters 61–68 and use the Program Keypad Module when the defaults need to be changed.
When a common preset-speed input operates multiple 160-BA01NPS1 / 160-AA02NPS1 drives, their TB3-7 commons must be connected as specified. If that chain is tied to another common, make the tie at one point only.
For control wiring longer than 15 m (50 ft), the optional 24 V DC interface is recommended for 160-BA01NPS1 / 160-AA02NPS1. It supports noise immunity where the internal 12 V input path would otherwise run over a long field cable.
No. The N enclosure code in 160-BA01NPS1 / 160-AA02NPS1 is an IP20 open-style construction. The installation must provide the environmental and access protection required around the drive.
Moore Automation supplies industrial automation spare parts through a catalog-number-led enquiry process, with one sales contact coordinating quotation details, packing, and shipment communication.
Send the complete model, quantity, and destination for a precise quotation.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found