Excitation path
The analyser applies an alternating excitation to the electrode pair of SC4A-S-PR-NN-002-05-T1.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Yokogawa SC4A-S-PR-NN-002-05-T1 Conductivity Sensor |
| Item NO. | 2945404 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | YOKOGAWA |
| Brand | YOKOGAWA |
| Creation Time | 2026-11-26 |
Retractable 19 mm two-electrode conductivity sensing
Exact code: stainless body, PR retractable configuration, 0.02 cm⁻¹ cell constant, 5 m cable and T1 temperature element.
The Yokogawa SC4A-S-PR-NN-002-05-T1 is a 19 mm two-electrode conductivity sensor in the SC4A family. Its stainless-steel body carries the electrode pair into the process, where the analyser applies excitation and calculates conductivity from the resulting current through the liquid.
The 0.02 cm⁻¹ cell constant of SC4A-S-PR-NN-002-05-T1 defines the relationship between electrode geometry and measured conductance. The T1 temperature element provides the process-temperature input used by the analyser to compensate conductivity to the configured reference temperature.
The PR configuration of SC4A-S-PR-NN-002-05-T1 is intended for the matching retractable fitting boundary rather than direct threaded insertion. Its 5 m integral cable carries electrode and temperature signals together, so cable routing and fitting selection are reviewed with the complete model code.
| Technical Item | SC4A-S-PR-NN-002-05-T1 |
|---|---|
| Brand | Yokogawa |
| Product Type | Two-electrode conductivity sensor |
| Brand Country | Japan |
| Body Diameter | 19 mm |
| Body / Electrode Material | Stainless steel AISI 316L |
| Process Configuration | PR retractable sensor body |
| Nominal Cell Constant | 0.02 cm⁻¹ |
| Cable Length | 5 m |
| Temperature Element | T1 option |
| Measuring Method | Contact conductivity, two electrodes |
| Sensor Length | 52 mm body dimension shown for PR type |
| Maximum Body Diameter | 27.5 mm at connector section |
| Installation Boundary | Use with applicable PR retractable fitting |
The analyser derives conductivity from an electrical path through the liquid and then corrects that result with measured temperature.
The analyser applies an alternating excitation to the electrode pair of SC4A-S-PR-NN-002-05-T1.
Ions in the process carry current between the two electrodes; higher conductance produces a larger response.
The 0.02 cm⁻¹ cell constant converts electrode conductance into the conductivity value used by the analyser.
The T1 element supplies temperature so the analyser can compensate the conductivity result.
The suffix defines a mechanical fitting boundary and a fixed signal route that must be preserved together.
The PR body enters the compatible retractable fitting, which establishes insertion depth and process sealing.
The stainless body and electrodes contact the process and must be checked against liquid chemistry.
The 5 m lead carries both conductivity and temperature circuits without an intermediate field splice.
The electrode area is positioned where process liquid can renew around the sensing surfaces without persistent gas pockets.
The PR field in SC4A-S-PR-NN-002-05-T1 defines its retractable mechanical arrangement. A fitting for an AD or sanitary SC4A body does not provide the same insertion and sealing boundary.
If SC4A-S-PR-NN-002-05-T1 reads low after installation, check for air around the electrodes, coating on the sensing surfaces and the configured cell constant. Establish complete wetting before changing calibration.
Route the 5 m SC4A-S-PR-NN-002-05-T1 cable away from motor and switching conductors and avoid unnecessary junctions. Connect both conductivity and temperature paths to their assigned analyser terminals.
SC4A-S-PR-NN-002-05-T1 carries separate electrode and T1 temperature circuits in the same cable. Check the temperature value and its wiring independently when compensation is wrong but conductivity remains stable.
Before retracting SC4A-S-PR-NN-002-05-T1, follow the procedure for the installed fitting and confirm its isolation, sealing and pressure state. The sensor code alone does not define a safe live-process removal sequence.
The complete SC4A-S-PR-NN-002-05-T1 code records stainless material, PR body, 002 cell constant, 05 cable length and T1 temperature element. Each field changes a separate mechanical or measurement characteristic.
One account manager follows each enquiry and remains the customer-facing contact for questions about the requested component. Product-code clarification, quantity changes and supporting photographs are recorded in the same conversation.
This continuity keeps later quotation revisions tied to the original requirement and gives the customer a consistent route for follow-up.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found