Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>WOODWARD>Woodward 9907-165 505E Digital Governor
Woodward 9907-165 505E Digital Governor

Woodward 9907-165 505E Digital Governor Item NO.: 2919435

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Woodward 9907-165 505E Digital Governor
Item NO. 2919435
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category WOODWARD
Brand Woodward
Creation Time 2026-10-14

Woodward 9907-165 505E Digital Governor
WOODWARDINDUSTRIAL TURBINE CONTROL

Woodward 9907-165 505E Digital Governor

505E steam turbine governor · controlled extraction/admission

01

Product Description

Woodward 9907-165 is a 505E digital governor for steam turbines with controlled extraction and/or admission pressure control. It executes the turbine control program that coordinates speed, load and the configured steam-valve demand.

For Woodward 9907-165, the control receives speed, pressure and operating-state information, processes the selected 505E configuration and drives the configured actuator outputs. The front-panel display and keypad provide the local path for setup, service and run-mode observation.

Woodward 9907-165 combines speed, pressure and operating-state inputs with the configured 505E extraction/admission loops. Its actuator outputs carry the resulting valve demand, while the front-panel display and keypad expose the active setpoints and run state.

02

Product Specifications

Technical Item 9907-165
Brand Woodward
Product type 505E digital governor
Control family 505E extraction/admission steam turbine control
Power option HVAC, 180–264 Vac
Actuator arrangement Single or split-range actuator control
Control modes Configuration, Service and Run
PID control Speed/load, auxiliary, auxiliary 2 and cascade loops
Operator interface Graphical display and keypad
Communications RS-232/RS-485 Modbus and Ethernet ports
Configuration Field programmable through menu-driven software
Optional enclosure NEMA 4X bulkhead mounting box 8923-439
03

Extraction and Admission Control

Woodward 9907-165 uses a field-programmable 505E configuration to define the turbine control loops and actuator behavior.

Selecting control options

Configuration mode selects the options required for the specific extraction or admission arrangement.

Programming the loops

The configured speed/load, auxiliary and cascade relationships determine how demands are calculated.

Protecting configuration access

Configuration and calibration access use the control’s user-level and password boundaries before settings are changed.

04

Operator and Modbus Control

During operation, Woodward 9907-165 presents control values and commands through the operator panel and actuator outputs.

Operating the turbine

Run mode carries the turbine from startup through shutdown using the configured control sequence.

Viewing setpoints

The display and keypad show actual and setpoint values while the control is operating.

Exchanging plant data

Modbus serial and Ethernet paths provide the configured data exchange with a DCS or HMI.

05

Frequently Asked Questions

Which power supply is assigned to Woodward 9907-165?

Woodward 9907-165 uses the HVAC option rated 180–264 Vac. Confirm the nameplate and supply frequency before energizing; do not use the AC/DC or LVDC option values from other 505E part numbers.

How should Woodward 9907-165 be configured for a split-range actuator?

Select the actuator and extraction/admission options in Configuration mode, then verify the resulting output assignments. The control must be configured for the actual turbine arrangement before entering Run mode.

What is the difference between Configuration, Service and Run on Woodward 9907-165?

Configuration selects the turbine options, Service is used for setup and adjustment, and Run is the normal operating state. Check the current mode before interpreting inactive outputs or locked settings.

Can Woodward 9907-165 communicate with a plant DCS?

Yes, through the configured Modbus serial or Ethernet path. Match the port, protocol and address settings on both sides before diagnosing a missing value.

What should be checked when a Woodward 9907-165 output does not follow a setpoint?

Check the selected PID relationship, actuator assignment and active mode in sequence. A display value alone does not confirm that the intended actuator output is configured.

Can the 9907-165 HVAC input be replaced by another 505E power option?

Do not substitute a different power option by appearance. Confirm the complete Woodward part number and supply class before any control replacement decision.

06

Quality & Warranty

MOORE AUTOMATION
https://www.mvme.cn/

Moore Automation applies product and condition checks to the requested Woodward part before the commercial record is completed, with refurbished or surplus status kept distinct from new equipment.

Exact model recordOriginal manufacturerQuantity confirmationOrder trace
www.mvme.cn

Enquiry Information

Send the complete model and requested quantity with your enquiry.

ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.