Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>WOODWARD>Woodward 8440-2086 easYgen-3500XT Low-Temperature Control
Woodward 8440-2086 easYgen-3500XT Low-Temperature Control

Woodward 8440-2086 easYgen-3500XT Low-Temperature Control Item NO.: 2919442

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Woodward 8440-2086 easYgen-3500XT Low-Temperature Control
Item NO. 2919442
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category WOODWARD
Brand Woodward
Creation Time 2026-10-14

Woodward 8440-2086 easYgen-3500XT Low-Temperature Control
WOODWARDINDUSTRIAL TURBINE CONTROL

Woodward 8440-2086 easYgen-3500XT Low-Temperature Control

easYgen-3500XT P1 · front-panel display · enhanced temperature option

01

Product Overview

Woodward 8440-2086 is an easYgen-3500XT P1 front-panel generator control with the enhanced low-temperature display option. It combines generator-control logic, electrical measurement and the operator display in the selected easYgen package.

For Woodward 8440-2086, the control measures generator, mains and bus quantities, evaluates synchronization and protection logic, and communicates configured values through CAN, Modbus and service interfaces. The P1 front-panel position defines how the operator reaches the display and terminals.

Woodward 8440-2086 measures generator, mains and bus conditions, applies the configured easYgen-3500XT logic and presents the result through its P1 front-panel display. CAN, Modbus and USB service paths carry the configured data and setup functions around that control loop.

02

Technical Specifications

Technical Item 8440-2086
Brand Woodward
Product type easYgen-3500XT generator control
Package P1 front-panel display, low-temperature option
Generator voltage Up to 690 VAC, three phase
Generator current 1 A or 5 A software selectable
Operating temperature Low-temperature display option; confirm exact specification
Modes Automatic, Manual, Stop and test
Breaker control Open/closed transition logic
Protection Generator, engine, mains and bus protection
Communication CAN, Ethernet Modbus TCP, USB serial and RS-485 Modbus RTU
Configuration PC configuration via USB serial and ToolKit
Event recorder Real-time-clock entries
Display Color display with softkey operation
03

Low-Temperature Generator Control

Woodward 8440-2086 combines measurement, synchronization and protection behavior within the easYgen-3500XT P1 operating package.

Measuring the power system

Generator, mains and bus values feed the configured control and protection decisions.

Running operating modes

Automatic, Manual, Stop and test modes determine how commands and breaker logic are executed.

Handling low temperature

The 8440-2086 display option is the temperature-specific part of the package; confirm that option before applying a temperature limit.

04

CAN and Modbus Connections

The interfaces of Woodward 8440-2086 connect the generator control to service software and plant-level devices.

CAN devices

FlexCAN connects supported Woodward control and expansion devices.

Modbus links

Ethernet Modbus TCP and RS-485 Modbus RTU carry configured control data.

ToolKit service path

USB serial provides the PC configuration and service connection.

05

Frequently Asked Questions

What is the low-temperature distinction of Woodward 8440-2086?

Woodward 8440-2086 is the easYgen-3500XT P1 front-panel display reference associated with the enhanced low-temperature option. Confirm the exact nameplate before assigning a temperature range.

Which current-transformer setting belongs to Woodward 8440-2086?

The easYgen control supports 1 A or 5 A current selection, but the configured value must match the installed CT circuit. Check the CT secondary and software setting together.

How should the communication ports of Woodward 8440-2086 be separated?

Keep CAN, Ethernet Modbus TCP, RS-485 Modbus RTU and USB service connections on their intended interfaces. Verify protocol and address settings before replacing a cable or port assignment.

What should be checked when the Woodward 8440-2086 display is available but breaker logic does not operate?

Check the selected operating mode, measurement validity and breaker feedback before changing the display or control file. The local display does not by itself prove that the command path is complete.

How is Woodward 8440-2086 configured?

Use the USB serial connection with the Woodward ToolKit configuration for the exact part number. Confirm the P1 display package and low-temperature option before saving the application.

Can another easYgen display variant be used as Woodward 8440-2086?

Do not assume display variants are interchangeable. Confirm the complete 8440-2086 identity, temperature option and terminal arrangement before making a variant decision.

06

Company Profile

MOORE AUTOMATION
https://www.mvme.cn/

Moore Automation covers PLC modules, DCS systems, HMI panels, drives, sensors and related industrial control parts, with the complete Woodward reference retained in the enquiry record.

Exact model recordOriginal manufacturerQuantity confirmationOrder trace
www.mvme.cn

Contact Information

Send the complete model and requested quantity with your enquiry.

ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.