Analog acquisition
Woodward 5466-315 accepts the assigned analog I/O signals and conditions them for the MicroNet channel data path.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Woodward 5466-315 / 5466-326 MicroNet I/O Modules |
| Item NO. | 2919916 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | WOODWARD |
| Brand | Woodward |
| Creation Time | 2026-10-15 |
MICRONET · I/O HARDWARE · ANALOG INPUT VARIANTS
HIGH-DENSITY I/O · PRESSURE INPUT PATH · CONTROL RACK
Woodward 5466-315 and Woodward 5466-326 are MicroNet I/O hardware variants used to bring field measurements into the MicroNet control system. The part numbers identify different I/O functions within the rack rather than a generic interchangeable board.
Within the rack, Woodward 5466-315 and Woodward 5466-326 terminate the assigned field signals, condition the input path and place the resulting channel data on the MicroNet backplane. The terminal type, channel assignment and signal class must remain matched to the exact module variant.
For Woodward 5466-315 and Woodward 5466-326, field conductors enter the assigned terminals, the module conditions the input and the resulting channel values pass through the MicroNet backplane to the control application. The 5466-326 pressure interface uses its specified two-channel transducer path, while 5466-315 serves the separate high-density I/O function.
| Technical Item | Specification |
|---|---|
| Brand | Woodward |
| Product type | MicroNet I/O module |
| Model group | 5466-315 / 5466-326 |
| System | MicroNet control system |
| 5466-315 role | High-density analog I/O variant |
| 5466-326 role | NetCon IIIB pressure-input variant |
| Signal path | Field terminals to conditioned channel data |
| Rack interface | MicroNet backplane |
| Selection boundary | Signal class and terminal arrangement are model-specific |
| Wiring boundary | Channel and common assignments follow the module variant |
| 5466-326 function | Pressure interface, 2 channels; 4 transducers per channel |
| 5466-326 field termination | FTM 5437-523; cable selection Table J |
| MicroNet signal route | Field wiring → FTM → cable → I/O module → VME motherboard → CPU/application |
Woodward 5466-315 and Woodward 5466-326 place different field measurement functions into the MicroNet I/O path.
Woodward 5466-315 accepts the assigned analog I/O signals and conditions them for the MicroNet channel data path.
Woodward 5466-326 is used for the pressure-input function identified by its part number and terminal record.
Each accepted field signal is represented as channel data for the control application through the rack interface.
The integration point for Woodward 5466-315 and Woodward 5466-326 is the relationship between field terminals, channel configuration and the MicroNet backplane.
The field conductors land on the terminals assigned to the selected module; a pressure input wiring set is not assumed for 5466-315.
The software channel map must match the physical slot and terminal group used by Woodward 5466-315 or Woodward 5466-326.
Conditioned channel values leave the I/O module through the MicroNet backplane for the controller application.
How do I choose the terminal wiring for Woodward 5466-315 / 5466-326?
Start from the exact module number and its channel record, then map each field conductor to the assigned terminal group. Woodward 5466-315 and Woodward 5466-326 have different I/O roles, so one terminal plan cannot be assumed for both.
Can a pressure transmitter be moved from Woodward 5466-315 / 5466-326 without changing the channel map?
No; verify the signal class, terminal assignment and software channel before moving the transmitter. The pressure-input role is specific to Woodward 5466-326 and should not be inferred for 5466-315.
What should be checked when Woodward 5466-315 / 5466-326 shows a channel fault after a rack change?
Check slot position, terminal group and backplane seating in that order. Then confirm that the channel map names the same module variant that is physically installed.
How can noise on Woodward 5466-315 / 5466-326 be isolated?
Compare the field signal at the terminal with the channel value reported through the MicroNet backplane. This separates field wiring noise from the module conversion and rack data path.
Is Woodward 5466-315 / 5466-326 a direct replacement pair?
Treat the two numbers as separate I/O functions unless the project record explicitly maps them. A similar rack footprint does not prove that a high-density analog module and a pressure-input module can be exchanged.
What record is needed before reterminating Woodward 5466-315 / 5466-326?
Record the installed slot, channel labels, common points and signal type before removing conductors. That information preserves the relationship between the physical terminals and the MicroNet software map.
Service support from Moore Automation keeps the manufacturer, I/O variant and terminal information visible while a request is prepared for review and response.
| HIMAF-PWR 02 | YokogawaAAI143-H53/K4A00 | EmersonPR9268-202-100 |
| ABB3HAC048232-001 | MotorolaMVME162-723 | GEIC670CHS002 |
| EmersonVE4003S2B1 | Bently Nevada330101-00-40-05-02-00 | Allen-Bradley1769-L24ER-QB1B |
| ABBPM891K01 | ABB Robotics3HAC034647-003 | GEIC660BPM100 |
| FoxboroFBM206 | Vibro-meterMPC4 | TRICONEX3626X |
| WoodwardRB5 | Allen-Bradley1734-IB8S | FoxboroRH914SQ |
| HoneywellCC-TCNT01 | ABB3HAC026289-001 | EmersonA6120 |
| YokogawaA2MMM843-SS1130 | HIMAF60 | EmersonVE4002S1T2B1 |
| Bently Nevada330101-00-20-10-02-05 | Allen-Bradley1769-L30ER | YokogawaVI702 |
| Siemens6ES7288-5DQ01-0AA0 | B&RX20CP1583 | EmersonIC695CPE330 |
| Bently Nevada330105-02-12-05-02-05 | ProSoftILX56-PBM | ICS TriplexT8310C |
| ABB3HAC055697-003 | Bently Nevada330130-035-00-05 | HIMAX-SB 01 |
| ProSoftPLX51-PBM | ABB3HNA018784-001 | FoxboroRH102AG |
| Vibro-meterCPUM | GEIC670MDL644 | Bently Nevada330101-00-16-10-02-00 |
| Allen-Bradley1769-L33ER | YokogawaALR121-S50 | Siemens6ES7288-3AT04-0AA0 |
| HIMAF8650E | ABB Robotics3HAC058991-004 | Siemens6ES7288-1ST30-0AA1 |
| Allen-Bradley5069-L306ER | HIMAF35 03/4(F35 034) | FoxboroFBM242 |
| Bently Nevada3500/42M-SIL2-09-01 | EmersonEPRO MMS6250 | HoneywellFC-TPSU-2430 |
| TRICONEX8108X | ABB3HNA023093-001 | GEIC670MDL330 |
| Siemens6ES7288-2DR16-0AA0 | FoxboroRH101RY | Allen-Bradley1734-RS232 |
Include the complete Woodward model and requested quantity so the enquiry remains tied to the correct configuration.
Moore Automation Sales Team