Schneider Electric / SCADAPack I/O Expansion
Schneider Electric TBUX297248 / 5304-20 Analog Output Module
Four-channel isolated 0-20 mA analog output module, Model 5304-20.
Product Overview
Four isolated current outputs for SCADAPack control
Schneider Electric TBUX297248 is the Model 5304-20 analog output module. This exact version provides four isolated 0-20 mA analog output channels.
The reference is listed for SCADAPack 47x, 57x, 500E, 300E, 300 and 32 systems. The -20 suffix is essential because other 5304 variants use different output ranges.
Official Schneider Electric 5304 current/voltage mode selection diagram.
Product Specifications
Official identification and technical data
| Brand | Schneider Electric |
|---|---|
| Reference | TBUX297248 |
| Model | 5304-20 |
| Product type | Analog output module |
| Analog outputs | 4 |
| Output range | 0-20 mA |
| Channel isolation | Isolated outputs |
| Range compatibility | SCADAPack 47x, 57x, 500E, 300E, 300 and 32 |
| Dimensions | 44 x 108 x 118 mm |
| Package weight | 0.73 kg |
| Relative humidity | 5-95% |
| Standard | UL 508 |
Operating Functions
Isolated analog current output control
Four channels
The module provides four independent analog output channels.
0-20 mA range
The 5304-20 version is specifically identified for 0-20 mA output.
Channel isolation
The official product description identifies isolated analog outputs.
SCADAPack integration
The module extends compatible SCADAPack controllers through the expansion system.
FAQ
Schneider Electric TBUX297248 / 5304-20 technical questions
What is the model number associated with TBUX297248?
The official product page identifies Model 5304-20.
How many analog outputs are provided?
Four.
What output range does this exact version use?
0-20 mA.
Are the outputs isolated?
Yes. The official description identifies four isolated analog outputs.
Why is the -20 suffix important?
It identifies the 0-20 mA version and prevents confusion with other 5304 output variants.
Installation Highlights
Model-suffix and system compatibility checks
Verify 5304-20
Use the complete model because other 5304 suffixes do not share the same output range.
Check controller family
Match TBUX297248 to the compatible SCADAPack system listed in the official characteristics.
Recommended Products
Additional industrial automation models
| Selection A | Selection B | Selection C |
|---|---|---|
| Siemens 6ES7214-1HG40-0XB0 | Omron CPM2A-30CDT1-D | Siemens 6ES7136-6BA01-0CA0 |
| Omron C500-OC224 | Siemens 6ES7510-1DJ01-0AB0 | Omron C500-LK009 |
| Siemens 6ES7215-1AG40-0XB0 | Omron C200H-B7A01 | Siemens 6ES7193-4CC30-0AA0 |
| Omron CP1L-M30DR-A | Siemens 6ES7211-1BE40-0XB0 | Omron CJ1M-CPU13 |
| Siemens 6ES7155-5AA00-0AA0 | Omron NX-ECC203 | Siemens 6ES7288-1ST60-0AA0 |
| Omron CV500-BSC41 | Siemens 6ES7138-4FA05-0AB0 | Omron C500-CPU11-V1 |
| Siemens 6ES7132-4BF00-0AA0 | Omron C500-OC223 | Siemens 6ES7144-4GF01-0AB0 |
| Omron CJ1W-MD261 | Siemens 6ES7953-8LP11 | Omron CJ2M-CPU13 |
| Siemens 6ES7953-8LG11 | Omron CJ1W-ID262 | Siemens 6ES7132-4BD32-0AA0 |
| Omron CQM1-AD041 | Siemens 6ES7193-6BP00-0DA1 | Omron CS1W-ID261 |
| Siemens 6ES7155-6AU00-0BN0 | Omron CJ1W-SCU41-V1 | Siemens 6ES7134-4FB52-0AB0 |
| Omron CJ1W-B7A04 | Siemens 6ES7131-6BH00-0BA0 | Omron CJ2M-CPU11 |
| Siemens 6ES7215-1HG40-0XB0 | Omron C500-OA226 | Siemens 6ES7241-1CH30-1XB0 |
| Omron CP1L-L20DT1-D | Siemens 6GK5208-0BA00-2AC2 | Mitsubishi Electric FX125A BN624A333H01 |
| Siemens 6ES7223-1BH32-0XB0 | Omron CPM1-20CDR-D | Siemens 6ES7288-3AM06-0AA0 |
| Mitsubishi Electric FX01B BN624A236H06 | Siemens 6ES7288-3AE08-0AA0 | Siemens 6ES7288-2DR32-0AA0 |
| Siemens 6ES7222-1BF32-0XB0 | Siemens 6ES7154-4AB10-0AB0 | Siemens 6ES7953-8LM32-0AA0 |
| Siemens 6ES7288-1SR60-0AA1 | Siemens 6ES7194-4AJ00-0AA0 | Siemens 6ES7155-6AR01-0AN0 |
| Siemens 6ES7234-4HE32-0XB0 | Siemens 6ES7313-5BF03-0AB0 | Siemens 6ES7510-1DK03-0AB0 |
| Siemens 6ES7155-6AU00-0CN0 | Siemens 6ES7511-1FK02-0AB0 | Siemens 6ES7541-1AB00-0AB0 |
Industrial Parts Enquiry
Send the exact model, required quantity and delivery destination for a focused quotation.






No related record found