Triconex safety-system hardware
Tri-GP digital output module · Tri-GP safety system · exact-model selection
On the Tri-GP output side, the Triconex DO3401S2 is a digital output module. It takes discrete commands from the Tri-GP controller and drives the configured field output channels through the S2-generation output path.
From the Tri-GP controller to the field, Triconex DO3401S2 converts a discrete software command into the on/off state assigned to a digital output point. The termination assembly carries that point to the connected field circuit, while the TriStation 1131 mapping identifies which physical point receives the command.
The S2 form of Triconex DO3401S2 also defines the 24 VDC output family used by the field circuit. The supply, load wiring, termination, and point assignment therefore describe one continuous controller-to-load path rather than separate generic 3401 features.
| Technical Item | DO3401S2 |
|---|---|
| Brand | Triconex |
| Product Type | Tri-GP digital output module |
| System | Tri-GP |
| Model Revision | S2 |
| Signal Direction | Controller to field |
| Channel Class | Digital output |
| Nominal Field Class | 24 VDC output family |
| Architecture | Tri-GP output path |
| Configuration | TriStation 1131 project |
| I/O Role | Output only |
| Termination | Digital output termination assembly |
| Point Mapping | Configured output points |
| Selection Check | Exact model, revision, and load wiring |
Triconex DO3401S2 converts controller output states into the field-side switching states assigned to the Tri-GP project.
The Tri-GP controller supplies the discrete command to the output module.
The configured output point drives its connected field circuit.
The software point number must remain aligned with the physical DO3401S2 termination.
Triconex DO3401S2 must be checked as an S2 Tri-GP output device with the correct field supply and load arrangement.
Confirm the field supply and load voltage belong to the 24 VDC output family.
Verify the connected load and termination wiring before enabling the point.
Retain the S2 suffix in the replacement and configuration record.
For Triconex DO3401S2, It takes a discrete command from the Tri-GP controller and drives the corresponding field-side on/off state through the digital output termination.
For Triconex DO3401S2, The signal travels from the Tri-GP controller to the field load. The termination assembly and configured point number identify the physical endpoint of that command.
The field supply and connected load belong to the 24 VDC output family identified for Triconex DO3401S2. The supply, load, and termination must describe the same output circuit.
S2 is part of the complete module identity, so the TriStation 1131 point mapping should show DO3401S2 rather than a generic 3401 label.
No. Triconex DO3401S2 is a digital output path that represents an on/off state, not an analog loop value.
The digital termination assembly carries the field circuit, while the TriStation 1131 point assignment names the corresponding output. Both records need the same DO3401S2 module position.