Signal entry
Analog field wiring enters the AI termination path.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Triconex AI3351S2 | Tri-GP analog input module |
| Item NO. | 2918965 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | TRICONEX |
| Brand | TRICONEX |
| Creation Time | 2026-10-13 |
Triconex safety-system hardware
Tri-GP analog input module · Tri-GP safety system · exact-model selection
Within the Tri-GP safety system, the Triconex AI3351S2 is an analog input module. It receives analog field measurements and presents them to the controller through the module’s triplicated input architecture, so the exact S2 hardware identity must remain intact during selection.
On the Tri-GP signal path, Triconex AI3351S2 receives an analog field measurement at its termination assembly and passes the value through a triplicated input path to the controller. Its role is therefore input-only; it does not issue a digital or analog output command.
Within the TriStation 1131 project, Triconex AI3351S2 is represented by its complete S2 model identity and its configured analog point. The chassis position, termination assembly, and field signal range must describe that same input path so the controller data point remains tied to the correct hardware.
| Technical Item | AI3351S2 |
|---|---|
| Brand | Triconex |
| Product Type | Tri-GP analog input module |
| System | Tri-GP |
| Model Revision | S2 |
| Signal Direction | Field to controller |
| Channel Class | Analog input |
| Architecture | Triplicated input path |
| Field Interface | Analog termination assembly |
| Configuration | TriStation 1131 project |
| Module Family | AI3351 |
| Suffix | S2 |
| I/O Role | Input only |
| Selection Check | Exact model and termination record |
Triconex AI3351S2 is selected when the system must acquire analog field values, not discrete states or commanded outputs.
Analog field wiring enters the AI termination path.
The acquired value is delivered to the Tri-GP controller data image.
The AI3351S2 suffix remains part of the configured module identity.
Triconex AI3351S2 must be matched to the Tri-GP chassis, termination, and software record as one installation set.
Use the configured Tri-GP analog input position.
The field termination assembly must match the AI module family.
The TriStation 1131 project must use the same complete model identity.
For Triconex AI3351S2, The analog field signal enters the matching termination assembly, passes through the triplicated AI path, and becomes a value in the Tri-GP controller data image. The module is therefore on the field-to-controller side.
For Triconex AI3351S2, The S2 suffix is part of the complete module identity used by the hardware and software records. Omitting it loses the revision detail needed to identify the configured AI point.
For Triconex AI3351S2, The Tri-GP chassis position, analog termination assembly, field signal range, and TriStation 1131 module record all describe the same analog input path. A mismatch breaks the relationship between the physical terminal and controller point.
For Triconex AI3351S2, No. Its signal direction is field to controller and its I/O role is analog input only; it is not a digital or analog output device.
The analog measurement is carried through the module’s triplicated input architecture before it is presented to the controller. The project mapping still needs the complete AI3351S2 identity and point assignment.
Keep AI3351S2 in the chassis list, termination record, and TriStation configuration so the analog input role is not confused with the similarly numbered output families.
https://www.mvme.cn/
Moore Automation keeps the requested model, quantity, and destination visible so a customer enquiry can be continued without losing its original details.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found