Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>SIEMENS>Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0 | SIMATIC S7-1500 Technology Modules
Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0 | SIMATIC S7-1500 Technology Modules

Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0 | SIMATIC S7-1500 Technology Modules Item NO.: 2927532

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0 | SIMATIC S7-1500 Technology Modules
Item NO. 2927532
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category SIEMENS
Brand SIEMENS
Creation Time 2026-10-27

Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0 SIMATIC S7-1500 Technology Modules
TM TIMER / PTO4

Siemens · Industrial Automation

Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0 | SIMATIC S7-1500 Technology Modules

One module for timestamped DI/DQ and one module for four pulse-train axes.

Timer moduleDIDQ 16×24 V
Motion modulePTO4
01

Product Overview

Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0 are SIMATIC S7-1500 technology modules for different time-critical tasks. The 6ES7552 timer module combines up to eight 24 V digital inputs and sixteen 24 V digital outputs with timestamp, counting, PWM and oversampling functions; the 6ES7553 PTO4 module generates pulse-train commands for as many as four axes.

Signal organization separates Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0 in the panel. The timer module assigns digital channels to event capture or precisely timed output functions, while each PTO4 channel provides a pulse-train output path plus two digital inputs and one digital output for axis-related signals.

Configuration of Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0 belongs in the CPU project rather than in a generic I/O replacement list. Timestamp resolution, oversampling or PWM settings on 6ES7552 and pulse/direction conventions, axis limits and drive wiring on 6ES7553 must be validated independently before machine operation.

02

Product Data

Technical Item 6ES7552-1AA00-0AB0 6ES7553-1AA00-0AB0
Brand Siemens
Product Name TM Timer DIDQ 16x24V TM PTO 4
Country Germany
Primary Function Timestamp, counting, PWM and oversampling Pulse-train positioning for up to four axes
Channel Architecture 0 DI / 16 DQ; 3 DI / 13 DQ; 4 DI / 12 DQ; or 8 DI / 8 DQ 4 axes; 3 configurable digital signals per channel including 1 DIQ
Digital Inputs Up to 8 × 24 V DC 2 DI plus 1 configurable DIQ per channel
Digital Outputs Up to 16 × 24 V DC 2 PTO signal outputs plus 1 configurable DIQ per channel
Signal Interfaces 24 V incremental or pulse encoder signals 24 V asymmetric, TTL 5 V asymmetric, or RS-422 symmetric
Timing / Motion Functions 1 µs timestamp, counting, PWM and input/output oversampling Pulse/direction, forward/reverse pulses, or phase-shifted signals
Maximum Count / Pulse Rate 200 kHz counting with quadruple evaluation 200 kHz at 24 V or TTL; 1 MHz at RS-422
Output Current / Protection 0.5 A standard or 0.1 A high-speed per DQ; short-circuit protection Electronic/thermal short-circuit protection on configurable DQ/DIQ paths
Load Supply Two 24 V DC load supplies; 19.2 to 28.8 V 24 V DC load supply; 19.2 to 28.8 V
No-Load Current 40 mA from 1L+ plus 30 mA from 2L+ maximum 70 mA maximum
Backplane-Bus Power 1.3 W
Typical Power Loss 5 W 4 W
Engineering Version STEP 7 TIA Portal V13 Update 3 or later STEP 7 TIA Portal V14 or later
Diagnostics Supply-voltage, short-circuit, channel and module diagnostics Supply-voltage, short-circuit, group and channel diagnostics
Operating Temperature 0 to 60 °C horizontal; 0 to 40 °C vertical 0 to 60 °C horizontal; 0 to 40 °C vertical with derating
Dimensions (W × H × D) 35 × 147 × 129 mm
Approximate Weight 320 g 300 g
03

Product Functions

Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0 move fast field events into deterministic controller functions, but one handles timed DIDQ data while the other controls pulse-train axes.

01

Timestamp and oversampling

Siemens 6ES7552-1AA00-0AB0 can capture selected input events with time information and sample or drive signals through configured high-speed functions, reducing dependence on an ordinary cyclic DI/DQ scan.

02

PWM and counting

Siemens 6ES7552-1AA00-0AB0 assigns channels to counting or PWM behavior in the hardware configuration. Input and output resources used by one function cannot be assumed free for another.

03

Four PTO channels

Siemens 6ES7553-1AA00-0AB0 supplies pulse-train paths for four configured channels. The pulse interface commands the external drive; position feedback and machine interlocks still follow the engineered axis design.

04

Configuration and Programming

A reliable project for Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0 starts with channel allocation, continues with timing or axis parameters, and ends with a measured test of the physical signal path.

1

Allocate resources first

List every input, output, timestamp, PWM, counter or PTO function before configuring Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0. Resolve channel conflicts before writing program logic.

2

Bind the application objects

Connect Siemens 6ES7552-1AA00-0AB0 event data to the intended program handling, and bind Siemens 6ES7553-1AA00-0AB0 to the correct PTO technology objects and drive conventions.

3

Commission at reduced risk

Test Siemens 6ES7552-1AA00-0AB0 with known pulses and compare timestamps; test Siemens 6ES7553-1AA00-0AB0 with the mechanism uncoupled or otherwise safely limited, confirming direction, enable and pulse scaling before full travel.

05

Questions About This Product

Why are timestamps from Siemens 6ES7552-1AA00-0AB0 inconsistent with the CPU time for 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0?

For 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0, check time synchronization, event configuration and the program path that reads Siemens 6ES7552-1AA00-0AB0 data. A captured hardware timestamp can be correct while later conversion or display uses a different time base.

Why does a drive connected to Siemens 6ES7553-1AA00-0AB0 move in the wrong direction for 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0?

For 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0, verify pulse/direction assignment, drive input logic and axis direction parameters for Siemens 6ES7553-1AA00-0AB0 before changing mechanical wiring. Limit travel and prove the direction at low speed.

Can Siemens 6ES7552-1AA00-0AB0 replace 6ES7553-1AA00-0AB0?

No. Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0 perform different technology functions and use different channel resources. A timer DIDQ configuration cannot execute a PTO4 axis project.

Why is PWM output absent on Siemens 6ES7552-1AA00-0AB0 for 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0?

For 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0, confirm that the selected Siemens 6ES7552-1AA00-0AB0 output is allocated to PWM, that its enable and period/duty parameters are valid, and that no competing configured function already owns that channel.

What causes missed motion pulses on Siemens 6ES7553-1AA00-0AB0 for 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0?

For 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0, inspect the Siemens 6ES7553-1AA00-0AB0 output wiring, reference potential, drive input specification and configured pulse rate. A rate beyond the drive or wiring capability can appear as position loss even when the controller command is correct.

What should be backed up before replacing Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0?

Keep the exact Siemens 6ES7552-1AA00-0AB0 / 6ES7553-1AA00-0AB0 article, firmware-compatible project, channel allocation, timing or axis parameters, addresses and wiring schedule. The physical module alone does not contain the full application behavior.

06

Customer Support

Moore Automation

https://www.mvme.cn

Moore Automation provides a clear enquiry route for industrial automation product, quantity and document questions.

The requested article and available technical records can be discussed together without presenting the company section as a substitute for engineering approval.

Model questionsExact article strings remain visible.
Document handlingAvailable technical files can be coordinated.
Quantity reviewRequested amounts stay with the enquiry.
Follow-upOne contact keeps responses connected.

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.