Programming connection
The LAN interface provides the published programming-device connection used to reach the CPU over Ethernet.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Siemens 6ES7288-1CR60-0AA0 | S7-200 SMART CR60 CPU |
| Item NO. | 2926368 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | SIEMENS |
| Brand | SIEMENS |
| Creation Time | 2026-10-23 |
Siemens · SIMATIC S7-200 SMART
Siemens 6ES7288-1CR60-0AA0 is a SIMATIC S7-200 SMART CPU CR60 AC/DC/Relay with thirty-six 24 V DC inputs and twenty-four relay outputs. It is the sixty-point compact CPU variant, combining the processor and the complete fixed digital terminal set in a 175 mm-wide housing.
Unlike an SR60, Siemens 6ES7288-1CR60-0AA0 does not accept expansion modules or a signal board. The 12 KB program, 8 KB data and 2 KB retentive memory operate only with the onboard I/O, so terminal capacity and program size are fixed at CPU selection.
Siemens 6ES7288-1CR60-0AA0 provides one 10/100 Mbit/s LAN port and one RS485 port, but its Ethernet services are not the PROFINET controller or I-Device functions available on ST/SR CPUs. The LAN path supports the published HMI, programming and open communication connections for the CR60, while RS485 remains available for serial protocols and freeport operation.
| Technical dossier | Confirmed model-specific values |
|---|---|
| Brand | Siemens |
| Model | 6ES7288-1CR60-0AA0 |
| Product Name | CPU CR60 AC/DC/Relay |
| Country | Germany |
| Dimensions (W × H × D) | 175 × 100 × 81 mm |
| Weight | 621.9 g |
| Power Dissipation | 10 W |
| Program / Data / Retentive Memory | 12 KB / 8 KB / 2 KB |
| Integrated Digital I/O | 36 inputs / 24 relay outputs |
| Expansion Modules / Signal Board | Not supported |
| 24 V Sensor Supply | 300 mA maximum |
| Ethernet Port | 1 × 10/100 Mbit/s LAN |
| Serial Interface | 1 × isolated RS485 |
| RS485 Freeport Rate | 1,200 to 115,200 bit/s |
| High-Speed Counters | 4 |
Siemens 6ES7288-1CR60-0AA0 uses its LAN port for supported programming, operator and open communication without acting as a PROFINET controller or I-Device.
The LAN interface provides the published programming-device connection used to reach the CPU over Ethernet.
Up to eight HMI connections can use the LAN service when the network and application parameters match.
Supported client/server and active/passive Ethernet communication is configured separately from the serial port.
Siemens 6ES7288-1CR60-0AA0 organizes thirty-six inputs and twenty-four relay outputs as one non-expandable local station.
The input terminals are distributed across the CPU connectors with their defined 24 V DC references.
The twenty-four outputs are arranged in relay groups that switch externally supplied AC or DC load circuits.
Because no expansion bus or signal board is available, every field point must be assigned to the integrated terminals.
Siemens 6ES7288-1CR60-0AA0 has a 10/100 Mbit/s LAN port, but its published communication profile does not provide PROFINET controller or I-Device operation. Configure only the Ethernet services supported by the CR60 instead of importing an ST/SR PROFINET topology.
Siemens 6ES7288-1CR60-0AA0 cannot accept expansion modules or a signal board. If the thirty-six inputs and twenty-four relay outputs are insufficient, the hardware architecture must move to an expandable CPU rather than adding a module beside the CR60.
The relay outputs of Siemens 6ES7288-1CR60-0AA0 are dry contacts that switch an external load source. Check the relevant common, field fuse and return path; the CPU does not supply load voltage through an unpowered relay group.
Record the exact Siemens 6ES7288-1CR60-0AA0 order number, project hardware entry, IP settings, RS485 parameters and terminal allocation. A replacement with a different CR60 suffix or an SR60 changes communication or expansion behavior even if the point count looks similar.
Siemens 6ES7288-1CR60-0AA0 uses separate Ethernet and RS485 interfaces. The RS485 network has its own wiring and protocol settings, so loss of the LAN path does not inherently stop a correctly configured serial exchange.
Check the 24 V input supply, common reference, field contact and wiring route at Siemens 6ES7288-1CR60-0AA0 before changing software filters. Compare the live terminal state with the process image so electrical noise is separated from program logic.
Moore Automation handles enquiries across Siemens, ABB, Rockwell Automation, Honeywell, Emerson, Schneider Electric, GE, Bently Nevada and other industrial-control families.
The scope covers PLC and CPU families, digital and analog I/O, DCS modules, HMI, drives and condition-monitoring hardware; the requested brand and exact model remain the first matching fields.
| Bently Nevada330101-00-20-10-02-05 | ABB BaileyIMHSS03 | TriconexTricon 4409 |
| B&RX20DO8331 | MotorolaMVME167-034B | HIMAF8621A |
| ABB BaileyIMFEC12 | TriconexTricon 4355X | FoxboroFBM202 |
| MotorolaMVME167-033B | HIMAF-PWR 02 | Bosch RexrothDKC01.3-040-7-FW |
| TriconexTricon 4353 | FoxboroFBM201D | Vibro-MeterVM600SYSMK2-001 |
| HIMAF7133 | Bosch RexrothDKC01.1-040-7-FW | YokogawaS2SC70D-FA12010 |
| FoxboroFBM201C | Vibro-MeterXIO16T Mk2 | ProSoftMVI69-MNET |
| Bosch RexrothHMS02.1N-W0070-A-07-NNNN | YokogawaALE111-S51 | Woodward5466-1245 |
| Vibro-MeterXMV16 | ProSoftMVI56-DFCM | HoneywellFC-UGAI01 |
| YokogawaALR121-S50 | Woodward5466-1145 | GEIC660BBA023 |
| ProSoftMVI56-MNET | HoneywellFC-TSRO-0824 | Rockwell Automation1734-OE2V |
| Woodward5466-1141 | GEIC660BBA021 | Siemens6ES7288-5AQ01-0AA0 |
| HoneywellFC-TSDI-16UNI | Rockwell Automation1734-OE2C | ABBCI867K01 |
| GEIC660BBA020 | Siemens6ES7288-5AE01-0AA0 | EmersonPR6424-010-140 |
| Rockwell Automation1734-IE2C | ABBCI840A | Bently Nevada330101-00-30-10-02-05 |
| Siemens6ES7288-5DQ01-0AA0 | EmersonPR6423-10R-010 | B&RX20AO4622 |
| ABBCI854AK01 | Bently Nevada330101-00-30-10-02-00 | ABB BaileySPBRC300 |
| EmersonPR6422-013-041 | B&RX20AI4622 | MotorolaMVME172-263 |
| Bently Nevada330101-00-20-90-02-05 | ABB BaileySPBRC400 | TriconexTricon 4609 |
| B&RX20DO9323 | MotorolaMVME172 | HIMAH7015A |
Use the direct contacts for product and delivery enquiries.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found