Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>VIBRO METER>Meggitt Vibro-Meter XIO16T 620-002-000-113 | VM600 extended input/output card
Meggitt Vibro-Meter XIO16T 620-002-000-113 | VM600 extended input/output card

Meggitt Vibro-Meter XIO16T 620-002-000-113 | VM600 extended input/output card Item NO.: 2919466

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Meggitt Vibro-Meter XIO16T 620-002-000-113 | VM600 extended input/output card
Item NO. 2919466
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category VIBRO METER
Brand OTHER PRODUCTS
Creation Time 2026-10-14

VM600 VM600Mk2 industrial monitoring hardware
VM600 / VM600MK2 INDUSTRIAL MONITORING HARDWAREExact model profile
XIO16TXIO16TVM600 XMV16/XIO16T measurement system

Meggitt Vibro-Meter VM600 hardware

Meggitt Vibro-Meter XIO16T 620-002-000-113 | VM600 extended input/output card

VM600 XMV16/XIO16T measurement system · provides dynamic and tachometer channel interfaces
VMVM600
Part number620-002-000-113
FormatVM600 I/O card
FamilyXIO16T
Dynamic inputs16 channels
Tachometer inputs4 channels

Serving the measurement interface, the Meggitt Vibro-Meter XIO16T 620-002-000-113 is a VM600 input/output card for dynamic measurement channels and tachometer signals. It organizes those two signal families on one card so the rack can receive measurement and rotational-reference data through separate connector paths.

On XIO16T 620-002-000-113, the tachometer path uses J2 while the dynamic channels use J3 and J4. The card is used with the XMV16 measurement arrangement, which presents the field-side signal connections for the VM600 rack.

The connector split on XIO16T 620-002-000-113 keeps tachometer timing separate from the dynamic measurement inputs. Those signals then enter the VM600 rack through the card interface for processing by the associated monitoring hardware.

Technical item
Brand Meggitt Vibro-Meter
Product type Dynamic and tachometer input/output card
Product family VM600
Part number 620-002-000-113
Card family XIO16T
Dynamic channels 16
Tachometer channels 4
Tachometer connector J2
Dynamic connectors J3 and J4
Associated arrangement XMV16
Signal groups Dynamic and tachometer paths
Rack role Measurement signal interface
Signal conditioning Analogue conditioning for sensor and measurement-chain inputs
Input protection EMI and signal-surge protection
Rack position Rear of ABE04x or ABE056 rack behind XMx16
Connector type S2L card connectors with B2CF/B2L plug-in compatibility
J3 channel allocation Dynamic channels CH1 to CH8
J4 channel allocation Dynamic channels CH9 to CH16
System Ethernet RJ45 interface for VibroSight or CPUx communication
Ethernet distance Up to 60 m at 1000 Mbps
Physical size 6U × 20 mm × 125 mm
Weight Approx. 0.32 kg
Rack connection Two connectors to the VM600 backplane
Field arrangement XMV16 measurement connection
Rack delivery Dynamic and tachometer data to VM600 rack

XIO16T 620-002-000-113 separates dynamic measurement and tachometer functions on the VM600 input/output card.

01 / INPUT

Dynamic inputs

The dynamic channels enter through the J3 and J4 connector group.

→
02 / PROCESS

Tachometer inputs

The tachometer signals enter through J2 as a separate signal family.

→
03 / OUTPUT

Rack delivery

Both signal groups are presented to the VM600 rack through the XIO16T card interface.

The connector assignment on XIO16T 620-002-000-113 determines which cable carries each signal family.

FIELD PATH

J2 position

J2 is used for the tachometer path and must remain separate from the dynamic-channel cables.

  • J3 and J4 positions

    J3 and J4 serve the dynamic measurement paths associated with the XMV16 arrangement.
  • Cable routing

    Keeping the connector groups separated preserves the intended signal flow into the rack.
  • Rack entry

    The separated cables enter the VM600 rack through the XIO16T measurement interface.

How are the channels divided on XIO16T 620-002-000-113?

XIO16T 620-002-000-113 provides sixteen dynamic input channels and a separate four-channel tachometer group. The channel groups are wired and interpreted differently, so the tachometer assignment must not be treated as another dynamic input bank.

Which connector carries the tachometer group on XIO16T 620-002-000-113?

In the rack path for XIO16T 620-002-000-113, the tachometer inputs are routed through J2, while the dynamic inputs use J3 and J4. Keeping those connector assignments separate prevents a tachometer cable from being placed on a dynamic input path.

What happens if a dynamic cable is connected to J2 on XIO16T 620-002-000-113?

To trace XIO16T 620-002-000-113, j2 is assigned to the tachometer group, so a dynamic signal connected there would not follow the intended channel map. Move the dynamic cable to its J3/J4 assignment and keep the tachometer wiring on J2.

How does XIO16T 620-002-000-113 reach the VM600 processing path?

XIO16T 620-002-000-113 does not choose the external protocol. The XIO16T card passes its dynamic and tachometer channel data through the VM600 rack arrangement to the associated processing module. The XMV16/XIO16T pair therefore has to be considered together when the channel map is checked.

What should be reviewed when one XIO16T 620-002-000-113 channel is absent?

When documenting XIO16T 620-002-000-113, review the connector group, the channel number and the associated XMV16/XIO16T rack pairing before changing software settings. A channel can appear absent when the physical cable is assigned to the wrong group.

Does XIO16T 620-002-000-113 act as the VM600 controller?

During a XIO16T 620-002-000-113 review, no. It is the input/output module for the extended condition-monitoring arrangement. The rack processing module handles acquisition and processing while XIO16T presents the assigned dynamic and tachometer channels.

Customer Support

MOORE AUTOMATION

https://www.mvme.cn/

Moore Automation provides a direct channel for questions about industrial automation parts, with the manager, email and WhatsApp route shown together.

A customer can send the complete model, quantity and destination in one message so the response stays connected to the requested hardware.

Manager contactEmail routeWhatsApp route
www.mvme.cn
SICKCLV430-6010
BeckhoffEL3154
SEW-EURODRIVEMC07B0022-2B1-4-00
ABB3bse008516r1
Siemens6EP1333-2BA20
GEIS200TDBTH6ACD
HoneywellCC-TSP411
Allen-Bradley1734-IB8S
OmronCPM2A-20CDR-A
Schneider ElectricBMXCRA31210
Rockwell Automation1756-L73XT
WAGO750-559
YaskawaSGD7F-2R8F00AY0829A
LenzeE82EV751_2C
Phoenix ContactMINI-PS-100-240AC/24DC/4
ABBDI3301
Siemens6ES7131-4BD01-0AA0
GEIC695PBM300-DC
HoneywellFC-IOTA-NR24
Mitsubishi ElectricFR-E740-0.4K-CHT
OmronCPM-MCVC-3421P-RLN
Schneider Electric140M-F8T-C25
Rockwell Automation22B-D012N104
WAGO750-483
YaskawaCACR-HR20SB
LenzeE82ZN22334B230
Phoenix ContactQUINT4-PS/1AC/24DC/5
ABBPM15-2
Siemens6ES7154-4AB10-0AB0
GEIC694CEE001-BA
Honeywell51308301-175
Mitsubishi ElectricFX3U-ENET-ADP
OmronNX-ID6142-5
Schneider Electric140DD084300
Rockwell Automation1769-OF8C
Allen-Bradley1734-OB8S
WAGO750-455
ABBAI523
Siemens6ES7972-0AB01-0XA0
GEIC2824-34
HoneywellCC-PUI031
Mitsubishi ElectricMR-J4-20TM-ECt
OmronNX-371
Schneider ElectricTSXSAY1000
Rockwell Automation1756-ENBT
Phoenix ContactQUINT-BUFFER/24DC/20
ABBDI561
Siemens6AG4141-5AF42-0DA0
GEIS200SCLTH1ABB
Honeywell51304441-175L
Mitsubishi ElectricMR-J2M-BU6
OmronCJ1W-ID212
Schneider ElectricATV320U75M3C
Rockwell Automation1746-IB16
WAGO852-112
LenzeE82EV371_2C
Phoenix ContactQUINT-PS/3AC/24DC/20
ABBACS150-03E-08A8-4
Siemens6ES7332-5HB01-0AB0
GEIS200TAMBH1ACB

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.